FHIR
Home
General
Motivation
Roadmap
Methodology
Certification relevant systems
Keywords and Conventions
Glossary
Release Notes
Definitions and Rules
General Considerations
Use of HL7 FHIR
Security and Privacy
Operational Requirements
System Overview
Logical Viewpoints
Information Model
Pairing
SMART Scopes
Retrieving Data
Access to BfArM Registries and ZTS
Generic APIs
FHIR Resource Server
Authorization Server
Error Codes
MIV-Specific APIs
Mandatory Interoperable Values (MIVs)
MIV - Blood Glucose Measurement
MIV - Continuous Glucose Measurement
MIV - Lung Function Testing
MIV - Blood Pressure Measurement
FHIR Artifacts
Artifacts Summary
Health Device Data Transfer
Version 1.0.0-rc2 - release
Specification of health data transfer from devices to DiGA (§ 374a SGB V)
Table of Contents
unten
|
nächste>
Table of Contents
0 Table of Contents
1 Overview
2 Motivation
3 Roadmap
4 Methodology
5 Certification relevant systems
6 Keywords and Conventions
7 Glossary
8 Release Notes
9 General Considerations
10 Use of HL7 FHIR
11 Security and Privacy
12 Operational Requirements
13 Logical Viewpoints
14 Information Model
15 Pairing
16 SMART Scopes
17 Retrieving Data
18 BfArM Registries and ZTS
19 FHIR Resource Server
20 Authorization Server
21 Mandatory Interoperable Values (MIVs)
22 MIV - Blood Glucose Measurement
23 MIV - Continuous Glucose Measurement
24 MIV - Lung Function Testing
25 MIV - Blood Pressure Measurement
26 Endpoint Observation
27 Endpoint Device
28 Endpoint DeviceMetric
29 Endpoint Metadata
30 Authorization Server Metadata Endpoint
31 Pushed Authorization Request Endpoint
32 Authorization Endpoint
33 Token Endpoint
34 Revocation Endpoint
35 Error Codes
36 Artifacts Summary
36.1 Search Operation for summary data measurement
36.2 Bundle – HDDT CGM Summary Report
36.3 Device – Personal Health Device
36.4 DeviceMetric – Sensor Type and Calibration Status
36.5 Observation - HDDT Blood Pressure Value
36.6 Observation – Blood Glucose Measurement
36.7 Observation – Complete Lung Function Testing
36.8 Observation – Continuous Glucose Measurement
36.9 Observation – Lung Function Reference Value
36.10 Observation – Lung Function Testing
36.11 Blood Glucose Measurement from LOINC
36.12 Blood Pressure Value from LOINC
36.13 Continuous Glucose Measurement from LOINC
36.14 Device Type of personal health devices
36.15 Lung Function Reference Value Method
36.16 Lung Function Reference Values from LOINC
36.17 Lung Function Relative Values from LOINC
36.18 Lung Function Testing Values from LOINC
36.19 MIV Lung Function Testing from LOINC
36.20 Lung Function Reference Value Method Codes
36.21 Lung Function Temporary Codes
36.22 Lung Function Temporary Codes to LOINC
36.23 HDDT Blood Glucose Measurement 1 (from Example Object Diagram)
36.24 HDDT Blood Glucose Measurement 2 (from Example Object Diagram)
36.25 HDDT Blood Glucose Obervation Example (general)
36.26 HDDT Blood Pressure Cuff DeviceDefinition Example
36.27 HDDT Blood Pressure Cuff Example
36.28 HDDT Blood Pressure Value Example
36.29 HDDT CGM Manufacturer Example
36.30 HDDT Glucometer Device Example
36.31 HDDT Glucometer DeviceDefinition Example
36.32 HDDT Glucometer DeviceMetric Example
36.33 HDDT Glucometer Manufacturer Example
36.34 HDDT Lung Function Obervation Example (FEV1 single measurement)
36.35 HDDT Lung Function Obervation Example (simple)
36.36 HDDT Lung Function Reference Value Obervation Example (FEV1 predicted)
36.37 HDDT Lung Function Relative Value Obervation Example (FEV1 measured/predicted)
36.38 HDDT Peak Flow Meter DeviceDefinition Example
36.39 HDDT Peak Flow Meter Example
36.40 HDDT rtCGM Data Unavailable Observation Example
36.41 HDDT rtCGM Device Example
36.42 HDDT rtCGM DeviceDefinition Example
36.43 HDDT rtCGM DeviceMetric Example
36.44 HDDT rtCGM Full Chunk Observation Example
36.45 HDDT rtCGM Full Chunk Observation Example
36.46 HDDT rtCGM Incomplete Chunk Observation Example
36.47 HDDT Universal Backend Auth Endpoint Example
36.48 HDDT Universal Backend FHIR Endpoint Example
36.49 HDDT Universal Device Backend Example
36.50 HL7 CGM Summary OperationOutcome Example: Bad syntax error
36.51 HL7 CGM Summary OperationOutcome Example: Invalid parameter error
36.52 HL7 CGM Summary OperationOutcome Example: No results information
36.53 HL7 CGM Summary OperationOutcome Example: Unknown parameter error
36.54 HL7 CGM Summary Patient Example: no content
36.55 HL7 CGM Summary: CGM Summary Example
36.56 HL7 CGM Summary: Coefficient of Variation Example
36.57 HL7 CGM Summary: Days of Wear Example
36.58 HL7 CGM Summary: Example Bundle
36.59 HL7 CGM Summary: GMI Example
36.60 HL7 CGM Summary: Mean Glucose (Mass) Example
36.61 HL7 CGM Summary: Mean Glucose (Molar) Example
36.62 HL7 CGM Summary: Sensor Active Percentage Example
36.63 HL7 CGM Summary: Times in Ranges Example