Specification of health data transfer from devices to DiGA (§ 374a SGB V)
| Official URL: https://gematik.de/fhir/hddt/ValueSet/hddt-lung-function-relative-values | Version: 1.0.0-rc2 | |||
| Active as of 2026-03-04 | Computable Name: HddtLungFunctionRelativeValues | |||
Copyright/Legal: gematik GmbH. This material contains content from LOINC. LOINC is copyright ©1995, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc. |
||||
Dieses ValueSet ist Teil der Health Device Data Transfer Spezifikation (HDDT), die Profile, Operationen und ValueSets für den Datenaustausch zwischen Hilfsmitteln und digitalen Gesundheitsanwendungen (DiGA) definiert.
Dieses ValueSet definiert die LOINC-Codes, die für relative Lungenfunktionswerte verwendet werden. Der relative Wert wird berechnet, indem die individuelle Messung durch den Referenzwert geteilt wird, was zu einem Prozentwert (%) führt. Enthaltene Codes sind für
–
This ValueSet is part of the Health Device Data Transfer specification (HDDT) which defines profiles, operations, and value sets for sharing data between medical aids and digital health applications (DiGA).
This ValueSet defines the LOINC codes, used for relative lung function values. The relative value is calculated by dividing the individual measurement by the reference value, resulting in a percentage value (%). Included codes are for
References
Language: en
Profile: Shareable ValueSet
This value set includes codes based on the following rules:
http://loinc.org version 📍2.81| Code | Display |
| 20152-5 | FEV1 measured/predicted |
https://gematik.de/fhir/hddt/CodeSystem/hddt-lung-function-temporary-codes version 📍1.0.0-rc2
| Code | Display |
| PEF-measured/predicted | PEF measured/predicted |
Expansion from tx.fhir.org based on:
This value set contains 2 concepts
| System | Code | Display (en) - English (English, en) | JSON | XML |
http://loinc.org | 20152-5 | FEV1 measured/predicted | ||
https://gematik.de/fhir/hddt/CodeSystem/hddt-lung-function-temporary-codes | PEF-measured/predicted | PEF measured/predicted |
Explanation of the columns that may appear on this page:
| Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
| System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
| Code | The code (used as the code in the resource instance) |
| Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
| Definition | An explanation of the meaning of the concept |
| Comments | Additional notes about how to use the code |