Specification of health data transfer from devices to DiGA (§ 374a SGB V)
| Active as of 2026-01-26 |
<ValueSet xmlns="http://hl7.org/fhir">
<id value="hddt-miv-continuous-glucose-measurement"/>
<meta>
<profile
value="http://hl7.org/fhir/StructureDefinition/shareablevalueset"/>
</meta>
<language value="en"/>
<text>
<status value="generated"/>
<div xml:lang="en" xmlns="http://www.w3.org/1999/xhtml" lang="en"><p class="res-header-id"><b>Generated Narrative: ValueSet hddt-miv-continuous-glucose-measurement</b></p><a name="hddt-miv-continuous-glucose-measurement"> </a><a name="hchddt-miv-continuous-glucose-measurement"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Language: en</p><p style="margin-bottom: 0px">Profile: <a href="http://hl7.org/fhir/R4/shareablevalueset.html">Shareable ValueSet</a></p></div><ul><li>Include these codes as defined in <a href="http://loinc.org"><code>http://loinc.org</code></a><span title="Version is not explicitly stated. No matching Code System found"> version Not Stated (use latest from terminology server)</span><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href="https://loinc.org/105272-9/">105272-9</a></td><td>Glucose [Moles/volume] in Interstitial fluid</td></tr><tr><td><a href="https://loinc.org/99504-3/">99504-3</a></td><td>Glucose [Mass/volume] in Interstitial fluid</td></tr></table></li></ul></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/resource-effectivePeriod">
<valuePeriod>
<start value="2026-02-01"/>
</valuePeriod>
</extension>
<extension url="http://hl7.org/fhir/StructureDefinition/artifact-author">
<valueContactDetail>
<name value="gematik GmbH"/>
</valueContactDetail>
</extension>
<url
value="https://gematik.de/fhir/hddt/ValueSet/hddt-miv-continuous-glucose-measurement"/>
<version value="1.0.0-rc"/>
<name value="HddtMivContinuousGlucoseMeasurement"/>
<title value="Continuous Glucose Measurement from LOINC"/>
<status value="active"/>
<experimental value="false"/>
<date value="2026-01-26"/>
<publisher value="gematik GmbH"/>
<contact>
<name value="gematik GmbH"/>
<telecom>
<system value="url"/>
<value value="https://www.gematik.de"/>
</telecom>
</contact>
<description
value="This ValueSet is part of the Health Device Data Transfer specification (HDDT) which defines profiles, operations, and value sets
for sharing data between medical aids and digital health applications (DiGA). Core of the HDDT specification are _Mandatory Interoperable
Values_ (MIVs). MIVs are classes of measurements that contribute to defined use cases and purposes of DiGA.
This ValueSet defines the Mandatory Interoperable Value (MIV) \"Continuous Glucose Measurement\". The definition is made up from
- this description which provides the semantics and defining characteristics of the MIV
- a set of LOINC codes that define MIV-compliant measurement classifications along the LOINC axes _component_, _system_, _scale_ and _method_
The MIV _Continuous Glucose Measurement_ covers values from continuous monitoring of the glucose level, e.g.
by rtCGM in interstitial fluid (ISF). Measurements are performed through sensors with a sample rate of up to
one value per minute (or even more). By this, the MIV _Continuous Glucose Measurement_ can e.g. be used to assess dependencies between a
patient's individual habits and behavious and his glucose level. Due to the high density of values over a long period
of time, many key metrics can be calculated from _Continuous Glucose Measurement_ which help the patient and
his doctor to easily capture the status of the patient's health and therapy.
The ValueSet for the MIV _Continuous Glucose Measurement_ includes codes relevant to continuous glucose
monitoring (CGM) in interstitial fluid (ISF), considering mass/volume and moles/volume as commonly used units.
In the future codes defining non-invasive glucose measuring methods may be added to this value set."/>
<copyright
value="gematik GmbH. This material contains content from [LOINC](http://loinc.org). LOINC is copyright ©1995, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at [http://loinc.org/license](http://loinc.org/license). LOINC® is a registered United States trademark of Regenstrief Institute, Inc."/>
<compose>
<include>
<system value="http://loinc.org"/>
<concept>
<code value="105272-9"/>
<display value="Glucose [Moles/volume] in Interstitial fluid"/>
</concept>
<concept>
<code value="99504-3"/>
<display value="Glucose [Mass/volume] in Interstitial fluid"/>
</concept>
</include>
</compose>
</ValueSet>