This specification describes the technical semantic approach for providing vital signs (vibW) using blood glucose, Continuous glucose monitoring, lung function testing and blood pressure as an example, according to § 374a SGB V.
first
true
ci-build
https://gemspec.gematik.de/ig/fhir/hddt/0.1.0
RelatedIgs
(None Found)
Error fetching package-list from https://gematik.de/fhir/hddt: Error parsing JSON source: Unexpected content '<' in json format at Line 3 (path=[null])
No publication request category found (needed for first publication - consult FHIR product director for a value
No publication request title found (needed for first publication)
No publication request introduction found (needed for first publication)
Unable to compare with previous version: Unable to find version history at https://gematik.de/fhir/hddt (Problem #1 with package-list.json at https://gematik.de/fhir/hddt: Error parsing JSON source: Unexpected content '<' in json format at Line 3 (path=[null]))
IPA Comparison:
n/a
IPS Comparison:
n/a
Validation Flags:
On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
INFORMATION: Blood Pressure component slicing. Reason: We use a custom HddtBloodPressureValue profile, IG Publisher trys to validate on the standard BP profile where the third component (mean blood pressure) is not part of.
%This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp% (1 uses)
INFORMATION: Conformance term check. Reason: The reference to § 374a SGB V is explanatory background text only and not intended as a formal conformance statement. The hit does not indicate an error in the specification and can be safely ignored.
%No conformance term found in the text% (6 uses)
INFORMATION: LOINC codes not validated for performance reasons.Reason: Triggers only on one ConceptMap that translates to LOINC. Since building process would take too long without a terminology server, ig-publisher does not validate codes from LOINC.
%Target Code System http://loinc.org is only supported on the terminology server% (1 uses)
INFORMATION: Missing publish box in generated HTML.Reason: This IG is not an official HL7 publication, so the 'publish box' requirement does not apply. The warning appears once per build and can safely be suppressed.
%The html source does not contain the publish box% (1 uses)
INFORMATION: References to draft CodeSystems. Reasson: The IG uses draft CodeSystems for internal testing or national extensions that are not yet normatively published.
%Reference to draft CodeSystem% (28 uses)
WARNING: HTML has duplicate Anchor IDs. Reason: The file `measurement-lung-function.md` embeds three Observation profiles, each with a distinct 'diff' table. IG-publisher generates HTML-anchors with duplicate ids for each table.
% The html source has duplicate anchor Ids: diff_Observation,% (1 uses)
WARNING: Best practice recommendations. # Reason: These warnings refer to "Best Practice Recommendations" (e.g., subject, performer) that are not mandatory for all Observation profiles in this IG context.
%Best Practice Recommendation% (71 uses)
WARNING: CodeSystem not found. Reason: This CodeSystem is currently not published.
%A definition for CodeSystem 'https://fhir.bfarm.de/CodeSystem/HiisEndpointConnectionType' could not be found, so the code cannot be validated% (2 uses)
%A definition for CodeSystem 'https://fhir.bfarm.de/CodeSystem/HiisManufacturerType' could not be found% (2 uses)
WARNING: Deprecated extension. Reason: The warning relates to an extension (elementdefinition-maxValueSet|5.2.0) that remains temporarily used for backward compatibility.
%The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.2.0 is deprecated% (1 uses)
WARNING: HTML fragment. Reason: We are using a custom template of our own
%HTML fragment% (4 uses)
WARNING: Observation performer / subject. Reason: Some Observation examples are intentionally abstracted or device-generated without explicit performer/subject for privacy or structural reasons.
%Alle Observations sollten ein Subject haben% (0 uses)
%Alle Observations sollten einen Performer haben% (0 uses)
WARNING: URL resolution for non-FHIR external systems. Reason: The URLs is a legitimate external reference (not a FHIR endpoint). It does not resolve via HTTP intentionally.
%No definition could be found for URL value% (2 uses)