Validation Results for gemIG_TI_Terminology

Generated Mon Jul 13 14:09:09 GMT 2026, FHIR version 4.0.1 for de.gematik.terminology#1.0.9-1 (canonical = https://gematik.de/fhir/terminology (history)). See Full QA Report & IP

Quality Checks
Publisher Version:IG Publisher Version: v2.2.10
Publication Code:n/a . PackageId = de.gematik.terminology, Canonical = https://gematik.de/fhir/terminology
Realm Check for n/a:
  • n/a
Language Info:This IG has no language information
Publication Request:
package-idde.gematik.terminology
version1.0.9-1
pathhttps://gematik.de/fhir/terminology/1.0.9-1
Pub-Modemilestone
statusrelease
Release-Labelrelease
Sequence (Group)TI (current: 'TI', others = n/a)
descImplementation Guide TI Terminology Version 1.0.9-1
RelatedIgs(None Found)
This release is labelled as a milestone, so should not have a patch version (1.0.9-1)
Supressed Messages:20 Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. de.gematik.terminology1.0.9-1R4https://gematik.de/fhir/terminology
... hl7.terminology.r47.2.0 MR4http://terminology.hl7.orghttp://terminology.hl7.org/7.2.0
.... hl7.fhir.uv.extensions.r45.3.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0
..... hl7.terminology.r47.1.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0Latest Release is 7.2.0
...... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0Latest Release is 5.3.0
... hl7.fhir.uv.extensions.r45.3.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0 (as above)
... dvmd.kdl.r42025.0.1 UR4
Templates: gematik.ig.template#0.0.4 -> fhir.base.template#1.0.0
Related IGs:n/a
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):https://tx.fhir.org/r4 (details)
HTA Analysis:Non-HL7 Igs are exempt from terminology dependency analysis
R5 Dependencies:
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Comparison with version 1.0.9
Comparison with version 1.0.8
Comparison with version 1.0.7
Comparison with version 1.0.5-4
IPA Comparison: n/a
IPS Comparison: n/a
Validation Flags: On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
Narratives SuppressedImplementationGuide/de.gematik.terminology, CodeSystem/aerztlicheBerufsvarianten, CodeSystem/epa-data-category-medical-cs, CodeSystem/epa-data-category-other-cs, CodeSystem/epa-drug-category-cs, CodeSystem/epa-vertraulichkeit-cs, CodeSystem/epa-xds-dokumenten-warnhinweise-frontend-cs, CodeSystem/epa-xds-dokumentenklassen-frontend-cs, CodeSystem/epa-xds-dokumententypen-frontend-cs, CodeSystem/epa-xds-einrichtungsarten-patientenbezogenen-frontend-cs, CodeSystem/epa-xds-fallkontexte-bei-dokumentenerstellung-frontend-cs, CodeSystem/epa-xds-nichtaerztliche-fachrichtungen-frontend-cs, CodeSystem/epa-zahnaerztliche-fachrichtungen-cs, CodeSystem/ti-medication-dispense-category-cs, CodeSystem/ti-organization-profession-type-oid-cs, CodeSystem/ti-organization-provider-type-cs, CodeSystem/ti-practitioner-profession-oid-cs, NamingSystem/ASTMSignatureTypeCodes, NamingSystem/DICOMAnatomicRegion, NamingSystem/DICOMControlledTerminology, NamingSystem/DICOMUidRegistry, NamingSystem/DataCategoryMedicalCS, NamingSystem/DataCategoryMedicalVS, NamingSystem/DataCategoryOtherCS, NamingSystem/DataCategoryOtherVS, NamingSystem/HL7Confidentiality, NamingSystem/HL7MimeTypes, NamingSystem/HL7TagsForTheIdentificationOfLanguages, NamingSystem/ICD10GM, NamingSystem/KBV-CS-SFHIR-KBV-DMP, NamingSystem/KDL, NamingSystem/LOINC, NamingSystem/OPS, StructureDefinition/valueset-expansion-deprecated, ValueSet/epa-data-category-medical-vs, ValueSet/epa-data-category-other-vs, ValueSet/epa-ehealth-dsi-healthcare-facility-type-vs, ValueSet/epa-mhd-security-label-vs, ValueSet/epa-structural-role-of-healthcare-professional-vs, ValueSet/epa-xds-author-role-vs, ValueSet/epa-xds-author-specialty-vs, ValueSet/epa-xds-class-code-vs, ValueSet/epa-xds-confidentiality-code-vs, ValueSet/epa-xds-content-type-code-vs, ValueSet/epa-xds-dokumenten-warnhinweise-frontend-vs, ValueSet/epa-xds-dokumentenklassen-frontend-vs, ValueSet/epa-xds-dokumententypen-frontend-vs, ValueSet/epa-xds-einrichtungsarten-patientenbezogenen-frontend-vs, ValueSet/epa-xds-fallkontexte-bei-dokumentenerstellung-frontend-vs, ValueSet/epa-xds-format-code-vs, ValueSet/epa-xds-healthcare-facility-type-code-vs, ValueSet/epa-xds-language-code-vs, ValueSet/epa-xds-mime-type-vs, ValueSet/epa-xds-nichtaerztliche-fachrichtungen-frontend-vs, ValueSet/epa-xds-practice-setting-code-vs, ValueSet/epa-xds-type-code-vs, ValueSet/ti-drug-category-vs, ValueSet/ti-medication-dispense-category-vs, ValueSet/ti-medication-dispense-status-vs, ValueSet/ti-medication-request-status-vs, ValueSet/ti-medication-type-pharmaceutical-product-vs, ValueSet/ti-medication-type-product-vs, ValueSet/ti-medication-type-vs, ValueSet/ti-organization-profession-type-oid-vs, ValueSet/ti-organization-type-vs, ValueSet/ti-practitioner-qualification-vs, ValueSet/epa-xds-event-code-vs
Validation SuppressedValueSet/epa-xds-event-code-vs, ValueSet/epa-xds-event-code-vs
CodeSystem FragmentsValueSet/epa-xds-event-code-vs, ValueSet/epa-xds-event-code-vs
Summary: errors = 0, warn = 84, info = 50, broken links = 0, pinned = n/a.
FilenameErrorsWarningsHints
Build Errors000
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-aerztlicheBerufsvarianten010
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-epa-drug-category-cs010
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-epa-xds-dokumenten-warnhinweise-frontend-cs010
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-epa-xds-dokumentenklassen-frontend-cs010
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-epa-xds-dokumententypen-frontend-cs010
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-epa-xds-einrichtungsarten-patientenbezogenen-frontend-cs010
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-epa-xds-fallkontexte-bei-dokumentenerstellung-frontend-cs010
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-epa-xds-nichtaerztliche-fachrichtungen-frontend-cs010
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-ti-medication-dispense-category-cs010
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-ti-organization-profession-type-oid-cs010
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-ti-organization-provider-type-cs010
/workspaces/dev-gem-terminology/fsh-generated/resources/CodeSystem-ti-practitioner-profession-oid-cs010
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-data-category-medical-vs031
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-data-category-other-vs031
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-ehealth-dsi-healthcare-facility-type-vs021
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-mhd-security-label-vs031
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-structural-role-of-healthcare-professional-vs031
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-author-role-vs011
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-author-specialty-vs011
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-class-code-vs021
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-confidentiality-code-vs011
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-content-type-code-vs011
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-dokumenten-warnhinweise-frontend-vs021
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-dokumentenklassen-frontend-vs021
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-dokumententypen-frontend-vs021
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-einrichtungsarten-patientenbezogenen-frontend-vs021
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-fallkontexte-bei-dokumentenerstellung-frontend-vs021
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-format-code-vs011
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-healthcare-facility-type-code-vs011
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-language-code-vs021
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-mime-type-vs011
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-nichtaerztliche-fachrichtungen-frontend-vs021
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-practice-setting-code-vs011
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-epa-xds-type-code-vs021
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-ti-drug-category-vs041
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-ti-medication-dispense-category-vs041
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-ti-medication-dispense-status-vs031
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-ti-medication-request-status-vs031
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-ti-medication-type-pharmaceutical-product-vs031
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-ti-medication-type-product-vs031
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-ti-medication-type-vs031
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-ti-organization-profession-type-oid-vs031
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-ti-organization-type-vs031
/workspaces/dev-gem-terminology/fsh-generated/resources/ValueSet-ti-practitioner-qualification-vs031

n/a Show Validation Information


fsh-generated/resources/CodeSystem-aerztlicheBerufsvarianten.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/aerztlicheBerufsvarianten should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-epa-drug-category-cs.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/epa-drug-category-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-epa-xds-dokumenten-warnhinweise-frontend-cs.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/epa-xds-dokumenten-warnhinweise-frontend-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-epa-xds-dokumentenklassen-frontend-cs.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/epa-xds-dokumentenklassen-frontend-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-epa-xds-dokumententypen-frontend-cs.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/epa-xds-dokumententypen-frontend-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-epa-xds-einrichtungsarten-patientenbezogenen-frontend-cs.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/epa-xds-einrichtungsarten-patientenbezogenen-frontend-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-epa-xds-fallkontexte-bei-dokumentenerstellung-frontend-cs.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/epa-xds-fallkontexte-bei-dokumentenerstellung-frontend-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-epa-xds-nichtaerztliche-fachrichtungen-frontend-cs.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/epa-xds-nichtaerztliche-fachrichtungen-frontend-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-ti-medication-dispense-category-cs.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/ti-medication-dispense-category-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-ti-organization-profession-type-oid-cs.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/ti-organization-profession-type-oid-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-ti-organization-provider-type-cs.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/ti-organization-provider-type-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/CodeSystem-ti-practitioner-profession-oid-cs.json Show Validation Information (0)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/ti-practitioner-profession-oid-cs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-epa-data-category-medical-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c2771)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c2771)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c2771)warningThe expansion provided is missing 11 codes (dentistry_oms, dermatology, gynaecology_urology, hospital, laboratory,...) that are in the expansion using default expansion parameters VALUESET_EXPANSION_MISSING--
ValueSet.expansion (l1/c2771)warningThe expansion provided is has 10 extra codes (dentistry_oms, dermatology, gynaecology_urology, hospital, laboratory,...) that are not in the expansion using default expansion parameters VALUESET_EXPANSION_EXTRA--

fsh-generated/resources/ValueSet-epa-data-category-other-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c5193)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c5193)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c5193)warningThe expansion provided is missing 25 codes (audit, care, child, childsrecord, dental,...) that are in the expansion using default expansion parameters VALUESET_EXPANSION_MISSING--
ValueSet.expansion (l1/c5193)warningThe expansion provided is has 24 extra codes (audit, care, child, childsrecord, dental,...) that are not in the expansion using default expansion parameters VALUESET_EXPANSION_EXTRA--

fsh-generated/resources/ValueSet-epa-ehealth-dsi-healthcare-facility-type-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1939)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1939)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ResourcewarningThe resource ValueSet/epa-ehealth-dsi-healthcare-facility-type-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-epa-mhd-security-label-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c6934)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c6934)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c6934)warningThe expansion provided is missing 9 codes (dentistry_oms, dermatology, gynaecology_urology, hospital, laboratory,...) that are in the expansion using default expansion parameters VALUESET_EXPANSION_MISSING--
ResourcewarningThe resource ValueSet/epa-mhd-security-label-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-epa-structural-role-of-healthcare-professional-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c4919)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c4919)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c4919)warningThe expansion provided has an extra code 44 that is not in the expansion using default expansion parameters VALUESET_EXPANSION_EXTRA--
ResourcewarningThe resource ValueSet/epa-structural-role-of-healthcare-professional-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-epa-xds-author-role-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c3998)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c3998)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--

fsh-generated/resources/ValueSet-epa-xds-author-specialty-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c51110)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c51110)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--

fsh-generated/resources/ValueSet-epa-xds-class-code-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c3153)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c3153)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c3153)warningBecause the expansion uses system 'http://loinc.org' without a version, it should list the system using the expansion parameter 'used-codesystem' --

fsh-generated/resources/ValueSet-epa-xds-confidentiality-code-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c2747)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c2747)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--

fsh-generated/resources/ValueSet-epa-xds-content-type-code-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c2182)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c2182)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--

fsh-generated/resources/ValueSet-epa-xds-dokumenten-warnhinweise-frontend-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1272)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1272)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ResourcewarningThe resource ValueSet/epa-xds-dokumenten-warnhinweise-frontend-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-epa-xds-dokumentenklassen-frontend-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c2132)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c2132)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ResourcewarningThe resource ValueSet/epa-xds-dokumentenklassen-frontend-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-epa-xds-dokumententypen-frontend-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1888)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1888)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ResourcewarningThe resource ValueSet/epa-xds-dokumententypen-frontend-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-epa-xds-einrichtungsarten-patientenbezogenen-frontend-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c2933)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c2933)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ResourcewarningThe resource ValueSet/epa-xds-einrichtungsarten-patientenbezogenen-frontend-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-epa-xds-fallkontexte-bei-dokumentenerstellung-frontend-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1739)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1739)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ResourcewarningThe resource ValueSet/epa-xds-fallkontexte-bei-dokumentenerstellung-frontend-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-epa-xds-format-code-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c29806)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c29806)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--

fsh-generated/resources/ValueSet-epa-xds-healthcare-facility-type-code-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c3876)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c3876)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--

fsh-generated/resources/ValueSet-epa-xds-language-code-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c23058)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c23058)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c23058)warningBecause the expansion uses system 'urn:ietf:bcp:47' without a version, it should list the system using the expansion parameter 'used-codesystem' --

fsh-generated/resources/ValueSet-epa-xds-mime-type-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1774)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1774)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--

fsh-generated/resources/ValueSet-epa-xds-nichtaerztliche-fachrichtungen-frontend-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1370)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1370)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ResourcewarningThe resource ValueSet/epa-xds-nichtaerztliche-fachrichtungen-frontend-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-epa-xds-practice-setting-code-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c12224)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c12224)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--

fsh-generated/resources/ValueSet-epa-xds-type-code-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c5960)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c5960)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c5960)warningBecause the expansion uses system 'http://loinc.org' without a version, it should list the system using the expansion parameter 'used-codesystem' --

fsh-generated/resources/ValueSet-ti-drug-category-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1441)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1441)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c1441)warningThe expansion provided is missing 4 codes (00, 01, 02, 03) that are in the expansion using default expansion parameters VALUESET_EXPANSION_MISSING--
ValueSet.expansion (l1/c1441)warningThe expansion provided is has 4 extra codes (00, 01, 02, 03) that are not in the expansion using default expansion parameters VALUESET_EXPANSION_EXTRA--
ResourcewarningThe resource ValueSet/ti-drug-category-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ti-medication-dispense-category-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1281)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1281)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c1281)warningThe expansion provided is missing 2 codes (non-prescription, prescription) that are in the expansion using default expansion parameters VALUESET_EXPANSION_MISSING--
ValueSet.expansion (l1/c1281)warningThe expansion provided is has 2 extra codes (non-prescription, prescription) that are not in the expansion using default expansion parameters VALUESET_EXPANSION_EXTRA--
ResourcewarningThe resource ValueSet/ti-medication-dispense-category-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ti-medication-dispense-status-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1552)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1552)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c1552)warningBecause the expansion uses system 'http://terminology.hl7.org/CodeSystem/medicationdispense-status' without a version, it should list the system using the expansion parameter 'used-codesystem' --
ResourcewarningThe resource ValueSet/ti-medication-dispense-status-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ti-medication-request-status-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1332)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1332)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c1332)warningBecause the expansion uses system 'http://hl7.org/fhir/CodeSystem/medicationrequest-status' without a version, it should list the system using the expansion parameter 'used-codesystem' --
ResourcewarningThe resource ValueSet/ti-medication-request-status-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ti-medication-type-pharmaceutical-product-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1182)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1182)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c1182)warningBecause the expansion uses system 'http://snomed.info/sct' without a version, it should list the system using the expansion parameter 'used-codesystem' --
ResourcewarningThe resource ValueSet/ti-medication-type-pharmaceutical-product-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ti-medication-type-product-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1081)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1081)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c1081)warningBecause the expansion uses system 'http://snomed.info/sct' without a version, it should list the system using the expansion parameter 'used-codesystem' --
ResourcewarningThe resource ValueSet/ti-medication-type-product-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ti-medication-type-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1943)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1943)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c1943)warningBecause the expansion uses system 'http://snomed.info/sct' without a version, it should list the system using the expansion parameter 'used-codesystem' --
ResourcewarningThe resource ValueSet/ti-medication-type-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ti-organization-profession-type-oid-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c11369)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c11369)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c11369)warningBecause the expansion uses system 'https://gematik.de/fhir/directory/CodeSystem/OrganizationProfessionOID' without a version, it should list the system using the expansion parameter 'used-codesystem' --
ResourcewarningThe resource ValueSet/ti-organization-profession-type-oid-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ti-organization-type-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c1311)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c1311)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c1311)warningBecause the expansion uses system 'https://gematik.de/fhir/directory/CodeSystem/OrganizationProviderType' without a version, it should list the system using the expansion parameter 'used-codesystem' --
ResourcewarningThe resource ValueSet/ti-organization-type-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-ti-practitioner-qualification-vs.json Show Validation Information (0)

PathSeverityMessageValidating
ValueSet.expansion (l1/c49577)warningThis expansion has no parameters; in the absence of the parameters that controlled the expansion, systems may not be able to determine whether it is safe to use this expansion --
ValueSet.expansion (l1/c49577)informationThis expansion has no identifier. Identifiers are recommended to help with audit and traceability VALUESET_EXPANSION_NO_IDENTIFIER--
ValueSet.expansion (l1/c49577)warningBecause the expansion uses system 'https://gematik.de/fhir/directory/CodeSystem/PractitionerProfessionOID' without a version, it should list the system using the expansion parameter 'used-codesystem' --
ResourcewarningThe resource ValueSet/ti-practitioner-qualification-vs should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

Suppressed Messages (Warnings, hints, broken links)

For compatibility with Polarion reasons the name has to start with "gem" and therefore voilates ig-0

Ignoring Warnings: We are using a custom template of our own

ImplementationGuide dvmd.kdl.r4 is not resolvable

In this case, no canonical URL is available or applicable for the referenced CodeSystem, so the OID is used as a fallback. This results in a validation error, which is known and cannot be avoided in the current context.

Incomplete CodeSystem cannot be validated

No description provied

SNOMED-CT version that cannot be resolved by tx.fhir.org

SNOMED-RT version that cannot be resolved by tx.fhir.org

The urn:oid for the CodeSystem is not resolvable

These are incorreclty flagged as draft (causes an information message since IG Pub 2.2.1)

This is an extension to mark value sets as deprecated and therefore should not be deprecated itself

We only want to use narratives if needed

We want to allow HTML tags in

Errors sorted by type


VALUESET_EXPANSION_EXTRA

fsh-generated/resources/ValueSet-epa-data-category-medical-vs.jsonThe expansion provided is has 10 extra codes (dentistry_oms, dermatology, gynaecology_urology, hospital, laboratory,...) that are not in the expansion using default expansion parameters--
fsh-generated/resources/ValueSet-epa-data-category-other-vs.jsonThe expansion provided is has 24 extra codes (audit, care, child, childsrecord, dental,...) that are not in the expansion using default expansion parameters--
fsh-generated/resources/ValueSet-epa-structural-role-of-healthcare-professional-vs.jsonThe expansion provided has an extra code 44 that is not in the expansion using default expansion parameters--
fsh-generated/resources/ValueSet-ti-drug-category-vs.jsonThe expansion provided is has 4 extra codes (00, 01, 02, 03) that are not in the expansion using default expansion parameters--
fsh-generated/resources/ValueSet-ti-medication-dispense-category-vs.jsonThe expansion provided is has 2 extra codes (non-prescription, prescription) that are not in the expansion using default expansion parameters--

VALUESET_EXPANSION_MISSING

fsh-generated/resources/ValueSet-epa-data-category-medical-vs.jsonThe expansion provided is missing 11 codes (dentistry_oms, dermatology, gynaecology_urology, hospital, laboratory,...) that are in the expansion using default expansion parameters--
fsh-generated/resources/ValueSet-epa-data-category-other-vs.jsonThe expansion provided is missing 25 codes (audit, care, child, childsrecord, dental,...) that are in the expansion using default expansion parameters--
fsh-generated/resources/ValueSet-epa-mhd-security-label-vs.jsonThe expansion provided is missing 9 codes (dentistry_oms, dermatology, gynaecology_urology, hospital, laboratory,...) that are in the expansion using default expansion parameters--
fsh-generated/resources/ValueSet-ti-drug-category-vs.jsonThe expansion provided is missing 4 codes (00, 01, 02, 03) that are in the expansion using default expansion parameters--
fsh-generated/resources/ValueSet-ti-medication-dispense-category-vs.jsonThe expansion provided is missing 2 codes (non-prescription, prescription) that are in the expansion using default expansion parameters--

VALUESET_EXPANSION_NO_IDENTIFIER

fsh-generated/resources/ValueSet-epa-data-category-medical-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-data-category-other-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-ehealth-dsi-healthcare-facility-type-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-mhd-security-label-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-structural-role-of-healthcare-professional-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-author-role-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-author-specialty-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-class-code-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-confidentiality-code-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-content-type-code-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-dokumenten-warnhinweise-frontend-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-dokumentenklassen-frontend-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-dokumententypen-frontend-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-einrichtungsarten-patientenbezogenen-frontend-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-fallkontexte-bei-dokumentenerstellung-frontend-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-format-code-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-healthcare-facility-type-code-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-language-code-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-mime-type-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-nichtaerztliche-fachrichtungen-frontend-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-practice-setting-code-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-epa-xds-type-code-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-ti-drug-category-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-ti-medication-dispense-category-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-ti-medication-dispense-status-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-ti-medication-request-status-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-ti-medication-type-pharmaceutical-product-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-ti-medication-type-product-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-ti-medication-type-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-ti-organization-profession-type-oid-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-ti-organization-type-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--
fsh-generated/resources/ValueSet-ti-practitioner-qualification-vs.jsonThis expansion has no identifier. Identifiers are recommended to help with audit and traceability--