Validation Results for ISiKOrganspendeerkennungImplementationGuide

Generated Wed Jul 01 12:24:50 UTC 2026, FHIR version 4.0.1 for organspendeerkennung#6.0.0 (canonical = https://gematik.de/fhir/isik (history)). See Errors Only & IP

Quality Checks
Publisher Version:IG Publisher Version: v2.2.10
Publication Code:n/a . PackageId = organspendeerkennung, Canonical = https://gematik.de/fhir/isik
Realm Check for n/a:
  • n/a
Language Info:Stated Languages: n/a. IG Resource Lang: n/a. 11 of 127 (8%) of resources have a language. Population Policy: NONE
Publication Request:
  • This IG has never been published
  • This IG has never been published, so the version should start with '0.' or include a patch version e.g. '-ballot'
  • No publication request found
Supressed Messages:15 Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. organspendeerkennung6.0.0R4https://gematik.de/fhir/isik
... hl7.terminology.r47.2.0 MR4http://terminology.hl7.orghttp://terminology.hl7.org/7.2.0
.... hl7.fhir.uv.extensions.r45.3.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0
..... hl7.terminology.r47.1.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0Latest Release is 7.2.0
...... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0Latest Release is 5.3.0
... hl7.fhir.uv.extensions.r45.3.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0 (as above)
... hl7.fhir.uv.xver-r5.r40.1.0 UR4http://hl7.org/fhir/uv/xverhttp://hl7.org/fhir/uv/xver-r5.r4/0.1.0
.... hl7.terminology.r47.1.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0 (as above). Latest Release is 7.2.0
.... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
.... hl7.terminology.r46.5.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/6.5.0Latest Release is 7.2.0
..... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
.... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
.... hl7.fhir.uv.ipa1.1.0 MR4http://hl7.org/fhir/uv/ipahttp://hl7.org/fhir/uv/ipa/STU1.1
..... hl7.terminology.r46.2.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/6.2.0Latest Release is 7.2.0
..... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
..... hl7.fhir.uv.smart-app-launch2.0.0 OR4http://hl7.org/fhir/smart-app-launchhttp://hl7.org/fhir/smart-app-launch/STU2Latest Release is 2.2.0
... hl7.fhir.uv.subscriptions-backport.r41.1.0 MR4http://hl7.org/fhir/uv/subscriptions-backporthttp://hl7.org/fhir/uv/subscriptions-backport/STU1.1FHIR Version Mismatch
.... hl7.terminology.r45.0.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.0.0Latest Release is 7.2.0
... de.basisprofil.r41.6.0 UR4
.... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
... de.ihe-d.terminology3.0.1 UR4http://fhir.de/packages/de.ihe-d.terminologyhttp://fhir.de/packages/de.ihe-d.terminology
... ihe.formatcode.fhir1.4.0 OR4https://profiles.ihe.net/fhir/ihe.formatcode.fhirhttps://profiles.ihe.net/fhir/ihe.formatcode.fhir/1.4.0Latest Release is 1.5.0
.... hl7.terminology.r46.3.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/6.3.0Latest Release is 7.2.0
..... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
.... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
... hl7.fhir.uv.sdc4.0.0 MR4http://hl7.org/fhir/uv/sdchttp://hl7.org/fhir/uv/sdc/STU4
.... hl7.terminology.r47.1.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0 (as above). Latest Release is 7.2.0
.... hl7.fhir.uv.xver-r5.r40.1.0 UR4http://hl7.org/fhir/uv/xverhttp://hl7.org/fhir/uv/xver-r5.r4/0.1.0 (as above)
.... hl7.fhir.uv.tools.r41.1.2 MR4http://hl7.org/fhir/toolshttp://hl7.org/fhir/tools/1.1.2
..... hl7.terminology.r47.1.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0 (as above). Latest Release is 7.2.0
..... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
.... hl7.fhir.r4.examples4.0.1 OR4http://hl7.org/fhirhttp://hl7.org/fhir/R4Latest Release is 5.0.0
.... hl7.fhir.uv.extensions.r45.3.0-ballot-tc1 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0-ballot-tc1Latest Release is 5.3.0
..... hl7.terminology.r46.5.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/6.5.0 (as above). Latest Release is 7.2.0
... de.gematik.terminology1.0.6 OR4https://gematik.de/fhir/terminologyhttps://gematik.de/fhir/terminology/1.0.6Latest Release is 1.0.9
.... hl7.terminology.r46.3.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/6.3.0 (as above). Latest Release is 7.2.0
.... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
.... dvmd.kdl.r42025.0.0 UR4
... de.gematik.ti1.3.1 MR4https://gematik.de/fhir/tihttps://gematik.de/fhir/ti/1.3.1
.... hl7.terminology.r47.1.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0 (as above). Latest Release is 7.2.0
.... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
.... de.basisprofil.r41.5.4 UR4
.... de.gematik.terminology1.0.9 MR4https://gematik.de/fhir/terminologyhttps://gematik.de/fhir/terminology/1.0.9
..... hl7.terminology.r47.1.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0 (as above). Latest Release is 7.2.0
..... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
..... dvmd.kdl.r42025.0.1 UR4
... de.fhir.medication1.0.7 MR4http://ig.fhir.de/igs/medicationhttp://ig.fhir.de/igs/medication/1.0.7
.... hl7.terminology.r47.2.0 MR4http://terminology.hl7.orghttp://terminology.hl7.org/7.2.0 (as above)
.... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
... hl7.fhir.uv.tools.r41.1.2 MR4http://hl7.org/fhir/toolshttp://hl7.org/fhir/tools/1.1.2Internal Dependency. (as above)
Templates: gematik.ig.template#0.0.1 -> fhir.base.template#0.8.1
Related IGs:n/a
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):http://tx.fhir.org/r4, https://tx.fhir.de/fhir, https://tx.fhir.org/r4 (details)
HTA Analysis:Non-HL7 Igs are exempt from terminology dependency analysis
R5 Dependencies:
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Unable to compare with previous version: Unable to find version history at https://gematik.de/fhir/isik (Problem #1 with package-list.json at https://gematik.de/fhir/isik: Not Found)
IPA Comparison: n/a
IPS Comparison: n/a
Validation Flags: On: autoLoad, displayWarnings; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent
Summary: errors = 38, warn = 361, info = 283, broken links = 39, pinned = n/a.
FilenameErrorsWarningsHints
Build Errors01012
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/fsh-generated/includes/fsh-link-references000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/fsh-generated/includes/menu000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/fsh-generated/resources/ImplementationGuide-organspendeerkennung181
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/images000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/images/Ampel_auf_Rot_Blau_gematik000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/images/Betriebskoordination_Gruen_gematik000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/images/sequenz-workflow000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/images/sequenzdiagramm-abfragen000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/includes/artifacts-table-generator-isik000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/includes/example-list-generator-isik000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/includes/ms-comments-data000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/Akteure000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/Festlegungen000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/Index_UseCaseAnwendung000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/List-ISiKMedikationsListe-notes000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/ProzesseUndWorkflows000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/ReleaseNotes000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/StructureDefinition-ISiKAllergieUnvertraeglichkeit-intro000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/StructureDefinition-ISiKDiagnose-intro000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/StructureDefinition-ISiKLaboruntersuchung-intro000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/_generate-ms-data000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/artifacts000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/pagecontent/index000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/CapabilityStatement-ISiKCapabilityStatementErweiterteStammdatenRolle011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/CapabilityStatement-ISiKCapabilityStatementOrganspendeerkennungSourceAkteur001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/CapabilityStatement-ISiKCapabilityStatementOrganspendeerkennungSourceAkteur-expanded011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/CapabilityStatement-ISiKCapabilityStatementOrganspendeerkennungSourceRolle011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/CapabilityStatement-ISiKCapabilityStatementStammdatenRolle011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/CodeSystem-ISiKBehandlungsergebnisRehaCS020
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/CodeSystem-ISiKBesondereBehandlungsformRehaCS020
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/CodeSystem-ISiKEncounterTypeErweiterungCS010
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/CodeSystem-ISiKEntlassformRehaCS020
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/CodeSystem-ISiKUnterbrechungRehaCS020
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-Fachabteilungskontakt242
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-FachabteilungskontaktBettenverlegung042
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-FachabteilungskontaktEntlassung031
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-FachabteilungskontaktFachbereichswechsel1042
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-FachabteilungskontaktFachbereichswechsel2031
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-FachabteilungskontaktMinimal2001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-FachabteilungskontaktNormal474
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-FachabteilungskontaktStationaereAufnahme031
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-FachabteilungskontaktStationswechsel1031
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-FachabteilungskontaktStationswechsel2031
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-SZ1Nachstationaer121
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-SZ1Stationaer141
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-SZ1Vorstationaer121
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-SZ2Encounter121
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Encounter-isik-encounter-Sternenfall042
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Location-KrankenhausStandortBeispiel111
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Location-StationICUStandortBeispiel111
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Location-StationPediaICUStandortBeispiel111
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Location-StationStandortBeispiel111
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Location-isik-station-anaesthesie111
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ExampleISiKLaboruntersuchungMaximal131
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ExampleISiKLaboruntersuchungSerumnatrium1110
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ExampleOrganPupilLightReactionLeft20200311011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ExampleOrganPupilLightReactionLeftPrompt20200311012
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ExampleOrganPupilLightReactionLeftVerzogert20200311012
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ExampleOrganPupilLightReactionRight20200311011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ExampleOrganPupilLightReactionRightKeine20200311012
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ExampleOrganRASS20200311211
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ExampleOrganSerumNatrium202003110104100
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ExampleOrganSerumNatrium202003110159100
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ExampleOrganSerumNatrium202003110306100
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ISiKGCSExample107
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ISiKGCSMaxExample117
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-ISiKGCSMinExample017
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Observation-Intrakranieller-Druck-ICP011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Parameters-exp-params000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Patient-DorisQuelle010
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Patient-DorisZiel010
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Patient-IsikPatientTemplate0110
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Patient-PatientinMinimal010
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Patient-PatientinMusterfrau030
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Patient-PatientinNormal010
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Patient-SZ1Patient010
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Patient-SZ2Patient010
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Patient-isik-patient-156722010
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Procedure-Appendektomie060
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Procedure-ExampleOrganVentilationMode20200311001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Procedure-ExampleOrganVentilationModeASV001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Procedure-ExampleOrganVentilationModeBiLev001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Procedure-ExampleOrganVentilationModeNIV001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Procedure-ExampleOrganVentilationModePCMod001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Procedure-ExampleOrganVentilationModePSIMV001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Procedure-ExampleOrganVentilationModeSPNMod001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Procedure-ExampleOrganVentilationModeStMod001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Procedure-ExampleOrganVentilationModenC001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/Procedure-ReanimationBeispiel111
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/SearchParameter-Encounter-date-start001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/SearchParameter-Encounter-end-date001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ExtensionISiKCapabilityStatementImportsExpectation021
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ExtensionISiKRehaEntlassung011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKCoding011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKGCS066
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung02713
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKLaboruntersuchung328
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKLaboruntersuchungSerumnatrium125
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKLoincCoding001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKPatient05719
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKProzedur085
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKProzedurBeatmung063
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKProzedurReanimation085
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKSnomedCTCoding001
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-ISiKStandort083
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-icu-muv-zerebraler-perfusionsdruck016
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-icu-score-rass005
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenbefund013
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenform013
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillengroesse033
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenlichtreaktion-direkt003
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenlichtreaktion-indirekt013
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillensymmetrie013
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-icu-vent-spontane-atemfrequenz-beatmet033
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-icu-vent-spontanes-atemzugvolumen033
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-icu-vent-unterstuezungsdruck-beatmung033
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-mii-pr-vent-icu-parameter-von-beatmung065
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-sd-mii-icu-intrakranieller-druck-icp003
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/StructureDefinition-sd-mii-icu-monitoring-und-vitaldaten018
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ISiKBehandlungsergebnisReha020
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ISiKBesondereBehandlungsformReha020
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ISiKEncounterClassDE021
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ISiKEncounterTypeErweiterungVS011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ISiKEntlassformReha020
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ISiKLaborMethodeVS010
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ISiKLaborbereichVS0114
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ISiKUnterbrechungReha020
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ObservationCodesSerumnatrium021
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ObservationUnitsSerumnatrium021
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ProzedurenCodesSCT020
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ProzedurenKategorieSCT023
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ProzedurenReanimationCodesOPS031
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-ProzedurenReanimationCodesSCT020
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-body-site-observation-beatmung010
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-bodysite-observation-pupillenbefund011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-category-procedure-beatmung-snomed011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc-iso11073017
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-snomed011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-code-observation-pupillengroesse011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-code-observation-pupillenlichtreaktion011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-code-observation-pupillensymmetrie011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-code-oservation-pupillenform-loinc011
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-code-procedure-beatmung-snomed013
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-mii-vs-icu-score-rass812
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-vs-mii-icu-bodysite-observation-monitoring-und-vitaldaten010
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-iso11073017
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-loinc018
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed0111
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/temp/pages/_includes/artifacts000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/template/config000
/__w/spec-ISiK-Basismodul/spec-ISiK-Basismodul/publisher-guides/Organspendeerkennung/template/config/_config000

n/a Show Validation Information

ImplementationGuide.dependency[6].urlwarningThe canonical URL for an Implementation Guide must point directly to the implementation guide resource, not to the Implementation Guide as a whole
warningUnable to find ImplementationGuide.definition.resource.description for the resource Procedure/Appendektomie. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Patient/DorisQuelle. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Patient/DorisZiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleISiKLaboruntersuchungMaximal. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleISiKLaboruntersuchungSerumnatrium1. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganPupilLightReactionLeft20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganPupilLightReactionLeftPrompt20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganPupilLightReactionLeftVerzogert20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganPupilLightReactionRight20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganPupilLightReactionRightKeine20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganRASS20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganSerumNatrium202003110104. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganSerumNatrium202003110159. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ExampleOrganSerumNatrium202003110306. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationMode20200311. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModeASV. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModeBiLev. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModeNIV. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModePCMod. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModePSIMV. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModeSPNMod. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModeStMod. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Procedure/ExampleOrganVentilationModenC. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/Fachabteilungskontakt. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktBettenverlegung. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktEntlassung. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktFachbereichswechsel1. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktFachbereichswechsel2. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktMinimal2. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktNormal. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktStationaereAufnahme. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktStationswechsel1. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/FachabteilungskontaktStationswechsel2. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ISiKGCSExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ISiKGCSMaxExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/ISiKGCSMinExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Location/isik-station-anaesthesie. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Observation/Intrakranieller-Druck-ICP. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Patient/IsikPatientTemplate. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Location/KrankenhausStandortBeispiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Patient/PatientinMinimal. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Patient/PatientinMusterfrau. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Patient/PatientinNormal. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Procedure/ReanimationBeispiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/SZ1Nachstationaer. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Patient/SZ1Patient. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/SZ1Stationaer. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/SZ1Vorstationaer. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/SZ2Encounter. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Patient/SZ2Patient. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Location/StationICUStandortBeispiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Location/StationPediaICUStandortBeispiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Location/StationStandortBeispiel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Parameters/exp-params. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Encounter/isik-encounter-Sternenfall. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource Patient/isik-patient-156722. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
output/Akteure.htmlinformationThe html source does not contain the publish box; this is recommended for publishing support (see note at https://confluence.hl7.org/spaces/FHIR/pages/66930646/FHIR+Implementation+Guide+Publishing+Requirements#FHIRImplementationGuidePublishingRequirements-PublishBox). Note that this is mandatory for HL7 specifications, and on the ci-build, but in other cases it's still recommended (this is only reported once, but applies for all pages)
CapabilityStatement-ISiKCapabilityStatementOrganspendeerkennungSourceAkteur-expanded​.html​#​/html​/body​/div​/div​/div​/div​/div​/p​/p​/a at Line 266, column 11warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ExtensionISiKCapabilityStatementImportsExpectation' for "CapabilityStatement-Imports-Expectation-Extension" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
CapabilityStatement-ISiKCapabilityStatementOrganspendeerkennungSourceAkteur​.html​#​/html​/body​/div​/div​/div​/div​/div​/p​/p​/a at Line 266, column 11warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ExtensionISiKCapabilityStatementImportsExpectation' for "CapabilityStatement-Imports-Expectation-Extension" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
Festlegungen​.html​#​/html​/body​/div​/div​/div​/div​/div​/p​/a at Line 214, column 321warningThe link 'https://gematik.de/fhir/isik/CapabilityStatement/ISiKCapabilityStatementStammdatenRolle' for "CapabilityStatement zur Stammdaten-Abfrage" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKGCS-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 370, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKGCS-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 386, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKGCS-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 749, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKGCS-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 759, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKGCS-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 1046, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKGCS-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 1072, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKGCS​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/div​/div​/table​/tbody​/tr​/td​/p​/a at Line 4130, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKGCS​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/div​/div​/table​/tbody​/tr​/td​/p​/a at Line 4175, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKKontaktGesundheitseinrichtung​.htmlinformationNo conformance term found in the text: 301 Abs. 3 SGB V. Dieser gehört zu den ‘Medizinischen Daten des Behandlungsfalls’ entsprechend der Definitionen für die Datenübermittlung nach CONFORMANCE_STATEMENT_NOCONFWORD
StructureDefinition-ISiKLaboruntersuchung-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 480, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKLaboruntersuchung-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 493, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKLaboruntersuchung-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 865, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKLaboruntersuchung-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 873, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKLaboruntersuchung-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 1351, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKLaboruntersuchung-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 1391, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKLaboruntersuchung​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/div​/div​/table​/tbody​/tr​/td​/p​/a at Line 4175, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKLaboruntersuchung​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/div​/div​/table​/tbody​/tr​/td​/p​/a at Line 4524, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKLaboruntersuchungSerumnatrium-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 467, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKLaboruntersuchungSerumnatrium-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 480, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKLaboruntersuchungSerumnatrium-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 1102, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKLaboruntersuchungSerumnatrium-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 1142, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedur-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 416, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedur-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 428, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedur-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 531, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedur-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 539, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedur-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 799, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedur-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 834, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedur​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/div​/div​/table​/tbody​/tr​/td​/p​/a at Line 2279, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedur​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/div​/div​/table​/tbody​/tr​/td​/p​/a at Line 2348, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedurBeatmung-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 416, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedurBeatmung-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 428, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedurBeatmung-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 701, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedurBeatmung-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 736, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedurReanimation-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 416, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedurReanimation-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 428, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedurReanimation-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 703, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient' for "ISiKPatient" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
StructureDefinition-ISiKProzedurReanimation-definitions​.html​#​/html​/body​/div​/div​/div​/div​/div​/div​/div​/table​/tr​/td​/p​/a at Line 738, column 62warningThe link 'https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung' for "ISiKKontaktGesundheitseinrichtung" is a canonical link and is therefore unsafe with regard to versions HTML_LINK_VERSIONLESS_CANONICAL
1warningThe HTML fragment 'ip-statements.xhtml' is not included anywhere in the produced implementation guide
2warningAn HTML fragment from the set [cross-version-analysis.xhtml, cross-version-analysis-inline.xhtml] is not included anywhere in the produced implementation guide
3warningAn HTML fragment from the set [dependency-table.xhtml, dependency-table-short.xhtml, dependency-table-nontech.xhtml] is not included anywhere in the produced implementation guide
4warningThe HTML fragment 'globals-table.xhtml' is not included anywhere in the produced implementation guide
5warningThe HTML fragment 'expansion-params.xhtml' is not included anywhere in the produced implementation guide

fsh-generated/includes/fsh-link-references.md Show Validation Information (0)


fsh-generated/includes/menu.xml Show Validation Information (0)


fsh-generated/resources/ImplementationGuide-organspendeerkennung.json Show Validation Information (1)

PathSeverityMessageValidating
ImplementationGuide​.dependsOn[5]​.uri (l1​/c2592)warningA definition could not be found for Canonical URL 'http://fhir.org/packages/de.basisprofil.r4/ImplementationGuide/de.basisprofil.r4' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVEImplementationGuide
ImplementationGuide​.definition​.resource[65]​.description (l1​/c44172)warningvalue should not start or finish with whitespace '\nDieses Profil ermöglicht die Abbildung von Besuchen/Aufenthalten eines Patienten in einer Gesundheitseinrichtung.\n\n**Motivation**\n\nInformationen über die Besuche des Patienten entlang seines \nBehandlungspfades im Krankenhaus sind ein wichtiger Bestandteil \ndes einrichtungsinternen Datenaustausches. \nSie ermöglichen die Unterscheidung von stationären und ambulanten \nsowie aufgenommenen und entlassenen Patienten. \nWeiterhin ist aus den Besuchsinformationen der aktuelle Aufenthaltsort \ndes Patienten (Fachabteilung, Station, Bettplatz) ermittelbar. \nKlinische Ressourcen werden in FHIR durch Verlinkung auf die \nEncounter-Ressource in einen Kontext zum Besuch gestellt. \nDieser Kontext ist wichtig für die Steuerung von Zugriffsberechtigungen \nund Abrechnungsprozessen. \n\nZu Beginn der meisten klinischen Workflows steht die Auswahl \ndes Besuchskontextes. \nDies geschieht bspw. durch das Suchen der Encounter-Ressource \nanhand von Eigenschaften wie Aufnahmenummer, Fallart oder Aufnahmedatum. \nDaraufhin werden die zutreffenden Suchergebnisse angezeigt \nund der gewünschte Besuch ausgewählt.\n\nIn FHIR werden Besuche, Aufenthalte, aber auch virtuelle Kontakte mit der `Encounter`-Ressource repräsentiert.\n\nWeitere Hinweise zu den Abgrenzungen der Begrifflichkeiten Fall und Kontakt finden sie unter [Fall-Begriff in ISiK](https://gemspec.gematik.de/ig/fhir/isik/basis/6.0.0-rc1/Abbildung-des-Konstrukts-Fall.html).\n\n**Kompatibilität**\n\nFür das Profil ISiKKontaktGesundheitseinrichtung wird eine Kompatibilität \nmit folgenden Profilen angestrebt; \nallerdings kann nicht sichergestellt werden, dass Instanzen, \ndie gegen ISiKKontaktGesundheitseinrichtung valide sind, \nauch valide sind gegen:\n\n* Profil [Kontakt mit einer Gesundheitseinrichtung \nder Medizininformatik-Initiative](https://www.medizininformatik-initiative.de/fhir/core/modul-fall/StructureDefinition/KontaktGesundheitseinrichtung)\n\nHinweise zu Inkompatibilitäten können über die [Portalseite](https://service.gematik.de/servicedesk/customer/portal/16) gemeldet werden.' Type_Specific_Checks_DT_String_WSImplementationGuide
ImplementationGuide​.definition​.resource[90]​.description (l1​/c66105)warningvalue should not start or finish with whitespace ' Zulaessige Koerperstellen fuer lateralisierte Pupillenbefunde: linke oder rechte Pupille.\n\nDie Datenstruktur wurde dem laufenden Stand der Entwicklung des MII ICU Module entnommen - https://github.com/medizininformatik-initiative/kerndatensatzmodul-intensivmedizin/blob/master/input/fsh/valuesets/MII_VS_ICU_BodySite_Observation_Pupillenbefund.fsh - Details zur Kompatibilität mit dem ISiK Package der Stufe 6 wurden angepasst und Metadaten des Ursprungsschemas zum Teil entfernt. Stand 04.03.2026' Type_Specific_Checks_DT_String_WSImplementationGuide
ImplementationGuide​.dependsOn[3] (l1​/c2251)warningThe ImplementationGuide uses package hl7.fhir.uv.ips#2.0.0 released on 2025-10-03, but the most recent appropriate version is 2.0.1. This reference is getting old and the more recent version should be considered IG_DEPENDENCY_VERSION_WARNING_OLD--
ImplementationGuide​.dependsOn[4] (l1​/c2477)warningThe ImplementationGuide is based on FHIR version 4.0.1 but package hl7.fhir.uv.subscriptions-backport.r4#1.1.0 is based on FHIR version 4.0.0. In general, this version mismatch should be avoided - some tools will try to make this work with variable degrees of success, but others will not even try IG_DEPENDENCY_VERSION_WARNING--
ImplementationGuide​.dependsOn[5] (l1​/c2643)warningThe canonical URL http://fhir.org/packages/de.basisprofil.r4/ImplementationGuide/de.basisprofil.r4 doesn't point to an actual ImplementationGuide resource IG_DEPENDENCY_INVALID_URL--
ImplementationGuide​.dependsOn[6] (l1​/c2779)errorThe URL should refer directly to the ImplementationGuide resource (e.g. include '/ImplementationGuide/')

Editor's Comment: The IHE package does not have an IG IG_DEPENDENCY_DIRECT
--
ImplementationGuide​.dependsOn[6] (l1​/c2779)warningThe canonical URL http://fhir.de/packages/de.ihe-d.terminology doesn't point to an actual ImplementationGuide resource IG_DEPENDENCY_INVALID_URL--
ImplementationGuide​.dependsOn[7] (l1​/c2958)warningThe ImplementationGuide uses package ihe.formatcode.fhir#1.4.0 released on 2025-05-20, but the most recent appropriate version is 1.5.0. This reference is getting old and the more recent version should be considered IG_DEPENDENCY_VERSION_WARNING_OLD--
ResourceinformationThe resource ImplementationGuide/organspendeerkennung could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/images Show Validation Information (0)


input/images/Ampel_auf_Rot_Blau_gematik.svg Show Validation Information (0)


input/images/Betriebskoordination_Gruen_gematik.svg Show Validation Information (0)


input/images/sequenz-workflow.png Show Validation Information (0)


input/images/sequenzdiagramm-abfragen.svg Show Validation Information (0)


input/includes/artifacts-table-generator-isik.html Show Validation Information (0)


input/includes/example-list-generator-isik.html Show Validation Information (0)


input/includes/ms-comments-data.html Show Validation Information (0)


input/pagecontent/Akteure.md Show Validation Information (0)


input/pagecontent/Festlegungen.md Show Validation Information (0)


input/pagecontent/Index_UseCaseAnwendung.md Show Validation Information (0)


input/pagecontent/List-ISiKMedikationsListe-notes.md Show Validation Information (0)


input/pagecontent/ProzesseUndWorkflows.md Show Validation Information (0)


input/pagecontent/ReleaseNotes.md Show Validation Information (0)


input/pagecontent/StructureDefinition-ISiKAllergieUnvertraeglichkeit-intro.md Show Validation Information (0)


input/pagecontent/StructureDefinition-ISiKDiagnose-intro.md Show Validation Information (0)


input/pagecontent/StructureDefinition-ISiKLaboruntersuchung-intro.md Show Validation Information (0)


input/pagecontent/_generate-ms-data.md Show Validation Information (0)


input/pagecontent/artifacts.md Show Validation Information (0)


input/pagecontent/index.md Show Validation Information (0)


input/resources/CapabilityStatement-ISiKCapabilityStatementErweiterteStammdatenRolle.json Show Validation Information (1)

PathSeverityMessageValidating
CapabilityStatement​.implementationGuide[0] (l1​/c12444)warningA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/ImplementationGuide/ISiK-Basismodul' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVECapabilityStatement
ResourceinformationThe resource CapabilityStatement/ISiKCapabilityStatementErweiterteStammdatenRolle could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/CapabilityStatement-ISiKCapabilityStatementOrganspendeerkennungSourceAkteur.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource CapabilityStatement/ISiKCapabilityStatementOrganspendeerkennungSourceAkteur could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/CapabilityStatement-ISiKCapabilityStatementOrganspendeerkennungSourceAkteur-expanded.json Show Validation Information (1)

PathSeverityMessageValidating
CapabilityStatement​.rest[0]​.resource[2]​.searchParam[6]​.definition (l1​/c90541)warningA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/SearchParameter/Location-characteristic' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVECapabilityStatement
ResourceinformationThe resource CapabilityStatement/ISiKCapabilityStatementOrganspendeerkennungSourceAkteur-expanded could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/CapabilityStatement-ISiKCapabilityStatementOrganspendeerkennungSourceRolle.json Show Validation Information (1)

PathSeverityMessageValidating
CapabilityStatement​.rest[0]​.resource[0]​.searchParam[6]​.definition (l1​/c37862)warningA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/SearchParameter/Location-characteristic' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVECapabilityStatement
ResourceinformationThe resource CapabilityStatement/ISiKCapabilityStatementOrganspendeerkennungSourceRolle could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/CapabilityStatement-ISiKCapabilityStatementStammdatenRolle.json Show Validation Information (1)

PathSeverityMessageValidating
CapabilityStatement​.implementationGuide[0] (l1​/c26251)warningA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/ImplementationGuide/ISiK-Basismodul' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVECapabilityStatement
ResourceinformationThe resource CapabilityStatement/ISiKCapabilityStatementStammdatenRolle could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/CodeSystem-ISiKBehandlungsergebnisRehaCS.json Show Validation Information (1)

PathSeverityMessageValidating
CodeSystem (l1/c2209)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING--
ResourcewarningThe resource CodeSystem/ISiKBehandlungsergebnisRehaCS should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/CodeSystem-ISiKBesondereBehandlungsformRehaCS.json Show Validation Information (1)

PathSeverityMessageValidating
CodeSystem (l1/c2653)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING--
ResourcewarningThe resource CodeSystem/ISiKBesondereBehandlungsformRehaCS should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/CodeSystem-ISiKEncounterTypeErweiterungCS.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource CodeSystem/ISiKEncounterTypeErweiterungCS should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/CodeSystem-ISiKEntlassformRehaCS.json Show Validation Information (1)

PathSeverityMessageValidating
CodeSystem (l1/c5052)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING--
ResourcewarningThe resource CodeSystem/ISiKEntlassformRehaCS should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/CodeSystem-ISiKUnterbrechungRehaCS.json Show Validation Information (1)

PathSeverityMessageValidating
CodeSystem (l1/c2866)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING--
ResourcewarningThe resource CodeSystem/ISiKUnterbrechungRehaCS should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/Encounter-Fachabteilungskontakt.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter​.identifier[0]​.system (l68​/c69)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/besuchsnummer' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter.status (l72/c23)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter​.diagnosis[0]​.condition (l94​/c8)errorUnable to resolve resource with reference 'Condition/BehandlungsDiagnoseFreitext' Reference_REF_CantResolveISiKKontaktGesundheitseinrichtung
Encounter.diagnosis[0].use (l97/c8)informationNone of the codings provided are in the value set 'DiagnosisRole' (http://hl7.org/fhir/ValueSet/diagnosis-role|4.0.1), and a coding is recommended to come from this value set (codes = http://fhir.de/CodeSystem/KontaktDiagnoseProzedur#treatment-diagnosis) Terminology_TX_NoValid_3_CCISiKKontaktGesundheitseinrichtung
Encounter.account[0] (l108/c6)errorUnable to resolve resource with reference 'Account/AbrechnungsfallDRG' Reference_REF_CantResolveISiKKontaktGesundheitseinrichtung
Encounter​.account[0]​.identifier​.system (l112​/c68)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/fallnummer' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[0]​.location​.identifier​.system (l165​/c70)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/locationid' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.serviceProvider​.identifier​.system (l174​/c72)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/fachabteilungsid' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-FachabteilungskontaktBettenverlegung.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter.location[2] (l91/c6)Slicing InformationThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKKontaktGesundheitseinrichtung
Encounter.status (l32/c26)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter​.location[0]​.location​.identifier​.system (l65​/c69)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[1]​.location​.identifier​.system (l84​/c68)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[2]​.location​.identifier​.system (l103​/c66)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[3]​.location​.identifier​.system (l125​/c66)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-FachabteilungskontaktEntlassung.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter.status (l32/c23)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter​.location[0]​.location​.identifier​.system (l66​/c69)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[1]​.location​.identifier​.system (l85​/c68)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[2]​.location​.identifier​.system (l104​/c66)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-FachabteilungskontaktFachbereichswechsel1.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter.location[2] (l92/c6)Slicing InformationThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKKontaktGesundheitseinrichtung
Encounter.status (l32/c23)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter​.location[0]​.location​.identifier​.system (l66​/c69)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[1]​.location​.identifier​.system (l85​/c68)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[2]​.location​.identifier​.system (l104​/c66)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[3]​.location​.identifier​.system (l126​/c66)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-FachabteilungskontaktFachbereichswechsel2.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter.status (l32/c26)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter​.location[0]​.location​.identifier​.system (l65​/c69)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[1]​.location​.identifier​.system (l84​/c68)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[2]​.location​.identifier​.system (l103​/c66)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-FachabteilungskontaktMinimal2.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter.status (l32/c23)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung

input/resources/Encounter-FachabteilungskontaktNormal.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter.location[2] (l178/c6)Slicing InformationThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKKontaktGesundheitseinrichtung
Encounter.location[3] (l188/c6)Slicing InformationThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKKontaktGesundheitseinrichtung
Encounter​.identifier[0]​.system (l69​/c69)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/besuchsnummer' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter.status (l73/c23)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter​.diagnosis[0]​.condition (l87​/c8)errorUnable to resolve resource with reference 'Condition/PrimaereGonarthroseNormal' Reference_REF_CantResolveISiKKontaktGesundheitseinrichtung
Encounter.diagnosis[0].use (l90/c8)informationNone of the codings provided are in the value set 'DiagnosisRole' (http://hl7.org/fhir/ValueSet/diagnosis-role|4.0.1), and a coding is recommended to come from this value set (codes = http://fhir.de/CodeSystem/KontaktDiagnoseProzedur#treatment-diagnosis) Terminology_TX_NoValid_3_CCISiKKontaktGesundheitseinrichtung
Encounter.account[0] (l102/c6)errorUnable to resolve resource with reference 'Account/AbrechnungsfallGonarthrose' Reference_REF_CantResolveISiKKontaktGesundheitseinrichtung
Encounter​.account[0]​.identifier​.system (l106​/c68)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/fallnummer' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[0]​.location (l139​/c8)errorUnable to resolve resource with reference 'Location/RaumStandortBeispiel' Reference_REF_CantResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[0]​.location​.identifier​.system (l142​/c66)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/roomid' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[1]​.location (l159​/c8)errorUnable to resolve resource with reference 'Location/BettenstellplatzStandortBeispiel' Reference_REF_CantResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[1]​.location​.identifier​.system (l162​/c65)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bedid' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[2]​.location​.identifier​.system (l181​/c69)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationid' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[3]​.location​.identifier​.system (l200​/c69)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationid' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.serviceProvider​.identifier​.system (l210​/c72)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/fachabteilungsid' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-FachabteilungskontaktStationaereAufnahme.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter.status (l32/c26)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter​.location[0]​.location​.identifier​.system (l65​/c69)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[1]​.location​.identifier​.system (l84​/c68)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[2]​.location​.identifier​.system (l103​/c66)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-FachabteilungskontaktStationswechsel1.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter.status (l32/c23)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter​.location[0]​.location​.identifier​.system (l66​/c69)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[1]​.location​.identifier​.system (l85​/c68)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[2]​.location​.identifier​.system (l104​/c66)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-FachabteilungskontaktStationswechsel2.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter.status (l32/c26)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter​.location[0]​.location​.identifier​.system (l65​/c69)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[1]​.location​.identifier​.system (l84​/c68)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[2]​.location​.identifier​.system (l103​/c66)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-SZ1Nachstationaer.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter​.identifier[0]​.system (l38​/c67)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/besuchsnummer' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter.status (l42/c23)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter.account[0] (l55/c6)errorUnable to resolve resource with reference 'Account/SZ1DRGFall' Reference_REF_CantResolveISiKKontaktGesundheitseinrichtung
Encounter​.account[0]​.identifier​.system (l58​/c67)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/fallnummern' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-SZ1Stationaer.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter​.identifier[0]​.system (l50​/c67)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/besuchsnummer' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter.status (l54/c23)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter.account[0] (l67/c6)errorUnable to resolve resource with reference 'Account/SZ1DRGFall' Reference_REF_CantResolveISiKKontaktGesundheitseinrichtung
Encounter​.account[0]​.identifier​.system (l70​/c67)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/fallnummern' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[0]​.location​.identifier​.system (l89​/c64)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/betten' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter​.location[1]​.location​.identifier​.system (l108​/c64)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/zimmer' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-SZ1Vorstationaer.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter​.identifier[0]​.system (l38​/c67)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/besuchsnummer' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter.status (l42/c23)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter.account[0] (l55/c6)errorUnable to resolve resource with reference 'Account/SZ1DRGFall' Reference_REF_CantResolveISiKKontaktGesundheitseinrichtung
Encounter​.account[0]​.identifier​.system (l58​/c67)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/fallnummern' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-SZ2Encounter.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter​.identifier[0]​.system (l38​/c67)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/besuchsnummer' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter.status (l42/c23)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter.account[0] (l55/c6)errorUnable to resolve resource with reference 'Account/SZ2DRGFall' Reference_REF_CantResolveISiKKontaktGesundheitseinrichtung
Encounter​.account[0]​.identifier​.system (l58​/c67)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/fallnummern' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Encounter-isik-encounter-Sternenfall.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter.location[0] (l46/c6)Slicing InformationThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKKontaktGesundheitseinrichtung
Encounter​.identifier[0]​.system (l29​/c70)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/aufnahmenummer' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung
Encounter.status (l33/c26)informationReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1 MSG_DRAFTISiKKontaktGesundheitseinrichtung
Encounter.class.display (l34/c4)warningWrong Display Name 'Inpatient' for http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP. There are no valid display names found for language(s) 'de-DE'. Default display is 'inpatient encounter' NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_ERRISiKKontaktGesundheitseinrichtung
Encounter.class (l34/c4)warningThe provided code 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP: 'Inpatient'' was not found in the value set 'https://gematik.de/fhir/isik/ValueSet/ISiKEncounterClassDE|6.0.0' ISiKKontaktGesundheitseinrichtung
Encounter​.account[0]​.identifier​.system (l65​/c68)warningNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/fallnummer' Type_Specific_Checks_DT_URL_ResolveISiKKontaktGesundheitseinrichtung

input/resources/Location-KrankenhausStandortBeispiel.json Show Validation Information (1)

PathSeverityMessageValidating
Location.identifier[0].system (l11/c58)warningNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer' Type_Specific_Checks_DT_URL_ResolveISiKStandort
Location​.type[0]​.coding[0]​.display (l23​/c6)informationThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-RoleCode#HOSP for language(s) 'de-DE'. The display is 'Hospital' which is a valid display for the default language NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKStandort
Location.managingOrganization (l53/c4)errorUnable to resolve resource with reference 'Organization/KrankenhausOrganisationBeispiel' Reference_REF_CantResolveISiKStandort

input/resources/Location-StationICUStandortBeispiel.json Show Validation Information (1)

PathSeverityMessageValidating
Location.identifier[0].system (l11/c58)warningNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer' Type_Specific_Checks_DT_URL_ResolveISiKStandort
Location​.type[0]​.coding[0]​.display (l23​/c6)informationThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-RoleCode#ICU for language(s) 'de-DE'. The display is 'Intensive care unit' which is a valid display for the default language NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKStandort
Location.managingOrganization (l53/c4)errorUnable to resolve resource with reference 'Organization/KlinikIntensivAnaesthesieOrganisationBeispiel' Reference_REF_CantResolveISiKStandort

input/resources/Location-StationPediaICUStandortBeispiel.json Show Validation Information (1)

PathSeverityMessageValidating
Location.identifier[0].system (l11/c58)warningNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer' Type_Specific_Checks_DT_URL_ResolveISiKStandort
Location​.type[0]​.coding[0]​.display (l23​/c6)informationThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-RoleCode#PEDICU for language(s) 'de-DE'. The display is 'Pediatric intensive care unit' which is a valid display for the default language NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKStandort
Location.managingOrganization (l49/c4)errorUnable to resolve resource with reference 'Organization/KlinikPaediatrieOrganisationBeispiel' Reference_REF_CantResolveISiKStandort

input/resources/Location-StationStandortBeispiel.json Show Validation Information (1)

PathSeverityMessageValidating
Location.identifier[0].system (l11/c58)warningNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer' Type_Specific_Checks_DT_URL_ResolveISiKStandort
Location​.type[0]​.coding[0]​.display (l23​/c6)informationThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-RoleCode#HU for language(s) 'de-DE'. The display is 'Hospital unit' which is a valid display for the default language NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKStandort
Location.managingOrganization (l53/c4)errorUnable to resolve resource with reference 'Organization/AbteilungAllgemeinchirurgieOrganisationBeispiel' Reference_REF_CantResolveISiKStandort

input/resources/Location-isik-station-anaesthesie.json Show Validation Information (1)

PathSeverityMessageValidating
Location.identifier[0].system (l11/c58)warningNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer' Type_Specific_Checks_DT_URL_ResolveISiKStandort
Location​.type[0]​.coding[0]​.display (l23​/c6)informationThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-RoleCode#ICU for language(s) 'de-DE'. The display is 'Intensive care unit' which is a valid display for the default language NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKStandort
Location.managingOrganization (l49/c4)errorUnable to resolve resource with reference 'Organization/KrankenhausOrganisationBeispiel' Reference_REF_CantResolveISiKStandort

input/resources/Observation-ExampleISiKLaboruntersuchungMaximal.json Show Validation Information (1)

PathSeverityMessageValidating
Observation.category[1] (l18/c6)informationNone of the codings provided are in the value set 'Observation Category Codes' (http://hl7.org/fhir/ValueSet/observation-category|4.0.1), and a coding is recommended to come from this value set (codes = http://loinc.org#18727-8) (from server, see log, or see the servers logic) Terminology_TX_NoValid_3_CCISiKLaboruntersuchung
Observation.performer[0] (l65/c6)errorUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt' Reference_REF_CantResolveISiKLaboruntersuchung
Observation​.value​.ofType(CodeableConcept) (l41​/c4)warningValueSet 'http://hl7.org/fhir/uv/ips/ValueSet/results-coded-values-laboratory-uv-ips' not found Terminology_TX_ValueSet_NotFoundISiKLaboruntersuchung
Observation​.value​.ofType(CodeableConcept)​.coding[0]​.display (l41​/c4)warningWrong Display Name 'Positiv' for http://snomed.info/sct#10828004. There are no valid display names found for language(s) 'de-DE'. Default display is 'Positive' (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_ERRISiKLaboruntersuchung
Observation​.method​.coding[0]​.display (l50​/c4)warningWrong Display Name 'Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique' for http://snomed.info/sct#83581000052107. There are no valid display names found for language(s) 'de-DE'. Default display is 'Matrix assisted laser desorption ionization time of flight mass spectrometry technique' (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_ERRISiKLaboruntersuchung

input/resources/Observation-ExampleISiKLaboruntersuchungSerumnatrium1.json Show Validation Information (1)

PathSeverityMessageValidating
Observation.performer[0] (l62/c6)errorUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt' Reference_REF_CantResolveISiKLaboruntersuchungSerumnatrium
Observation​.referenceRange[0]​.appliesTo[0]​.coding[0]​.display (l45​/c10)warningWrong Display Name 'Weiblich' for http://snomed.info/sct#248152002. There are no valid display names found for language(s) 'de-DE'. Default display is 'Female' (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_ERRISiKLaboruntersuchungSerumnatrium

input/resources/Observation-ExampleOrganPupilLightReactionLeft20200311.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.code​.coding[0]​.display (l10​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#45832002 for language(s) 'de-DE'. The display is 'Pupil afferent light reaction' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer--

input/resources/Observation-ExampleOrganPupilLightReactionLeftPrompt20200311.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.code​.coding[0]​.display (l10​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#45832002 for language(s) 'de-DE'. The display is 'Pupil afferent light reaction' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
Observation​.value​.ofType(CodeableConcept)​.coding[0]​.display (l43​/c4)informationThere are no valid display names found for the code http://loinc.org#LA25441-9 for language(s) 'de-DE'. The display is 'Reactive to light' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer--

input/resources/Observation-ExampleOrganPupilLightReactionLeftVerzogert20200311.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.code​.coding[0]​.display (l10​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#45832002 for language(s) 'de-DE'. The display is 'Pupil afferent light reaction' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
Observation​.value​.ofType(CodeableConcept)​.coding[0]​.display (l43​/c4)informationThere are no valid display names found for the code http://loinc.org#LA24899-9 for language(s) 'de-DE'. The display is 'Sluggishly reactive to light' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer--

input/resources/Observation-ExampleOrganPupilLightReactionRight20200311.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.code​.coding[0]​.display (l10​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#45832002 for language(s) 'de-DE'. The display is 'Pupil afferent light reaction' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer--

input/resources/Observation-ExampleOrganPupilLightReactionRightKeine20200311.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.code​.coding[0]​.display (l10​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#45832002 for language(s) 'de-DE'. The display is 'Pupil afferent light reaction' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
Observation​.value​.ofType(CodeableConcept)​.coding[0]​.display (l43​/c4)informationThere are no valid display names found for the code http://loinc.org#LA25442-7 for language(s) 'de-DE'. The display is 'Not reactive to light' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer--

input/resources/Observation-ExampleOrganRASS20200311.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.code​.coding[0]​.display (l30​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#1345050000 for language(s) 'de-DE'. The display is 'Richmond Agitation Sedation Scale score' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKMII PR ICU Score RASS
Observation​.value​.ofType(CodeableConcept)​.coding[0]​.code (l20​/c4)errorUnknown code 'LA33966-5' in the CodeSystem 'http://loinc.org' version '2.82' (from https://tx.fhir.org/r4, see log, or see the servers logic) Unknown_Code_in_VersionMII PR ICU Score RASS
Observation​.value​.ofType(CodeableConcept) (l20​/c4)errorNone of the codings provided are in the value set 'MII VS ICU Score RASS' (https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0), and a coding from this value set is required) (codes = http://loinc.org#LA33966-5) (from server, see log, or see the servers logic) Terminology_TX_NoValid_1_CCMII PR ICU Score RASS
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer--

input/resources/Observation-ExampleOrganSerumNatrium202003110104.json Show Validation Information (1)

PathSeverityMessageValidating
Observation.performer[0] (l38/c6)errorUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt' Reference_REF_CantResolveISiKLaboruntersuchungSerumnatrium

input/resources/Observation-ExampleOrganSerumNatrium202003110159.json Show Validation Information (1)

PathSeverityMessageValidating
Observation.performer[0] (l38/c6)errorUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt' Reference_REF_CantResolveISiKLaboruntersuchungSerumnatrium

input/resources/Observation-ExampleOrganSerumNatrium202003110306.json Show Validation Information (1)

PathSeverityMessageValidating
Observation.performer[0] (l38/c6)errorUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt' Reference_REF_CantResolveISiKLaboruntersuchungSerumnatrium

input/resources/Observation-ISiKGCSExample.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.code​.coding[0]​.display (l25​/c4)informationThere are no valid display names found for the code http://loinc.org#9269-2 for language(s) 'de-DE'. The display is 'Glasgow coma score total' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation.performer[0] (l112/c6)errorUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt' Reference_REF_CantResolveISiKGCS
Observation​.component[0]​.code​.coding[0]​.display (l46​/c8)informationThere are no valid display names found for the code http://loinc.org#9270-0 for language(s) 'de-DE'. The display is 'Glasgow coma score verbal' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[0]​.value​.ofType(CodeableConcept)​.coding[0]​.display (l55​/c8)informationThere are no valid display names found for the code http://loinc.org#LA6560-2 for language(s) 'de-DE'. The display is 'Confused' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[1]​.code​.coding[0]​.display (l66​/c8)informationThere are no valid display names found for the code http://loinc.org#9268-4 for language(s) 'de-DE'. The display is 'Glasgow coma score motor' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[1]​.value​.ofType(CodeableConcept)​.coding[0]​.display (l75​/c8)informationThere are no valid display names found for the code http://loinc.org#LA6566-9 for language(s) 'de-DE'. The display is 'Localizing pain' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[2]​.code​.coding[0]​.display (l86​/c8)informationThere are no valid display names found for the code http://loinc.org#9267-6 for language(s) 'de-DE'. The display is 'Glasgow coma score eye opening' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[2]​.value​.ofType(CodeableConcept)​.coding[0]​.display (l95​/c8)informationThere are no valid display names found for the code http://loinc.org#LA6555-2 for language(s) 'de-DE'. The display is 'Eye opening to verbal command' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS

input/resources/Observation-ISiKGCSMaxExample.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.code​.coding[0]​.display (l25​/c4)informationThere are no valid display names found for the code http://loinc.org#9269-2 for language(s) 'de-DE'. The display is 'Glasgow coma score total' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation.performer[0] (l112/c6)errorUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt' Reference_REF_CantResolveISiKGCS
Observation​.interpretation[0]​.coding[0]​.display (l117​/c6)informationThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation#N for language(s) 'de-DE'. The display is 'Normal' which is a valid display for the default language NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[0]​.code​.coding[0]​.display (l46​/c8)informationThere are no valid display names found for the code http://loinc.org#9270-0 for language(s) 'de-DE'. The display is 'Glasgow coma score verbal' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[0]​.value​.ofType(CodeableConcept)​.coding[0]​.display (l55​/c8)informationThere are no valid display names found for the code http://loinc.org#LA6558-6 for language(s) 'de-DE'. The display is 'Incomprehensible sounds' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[1]​.code​.coding[0]​.display (l66​/c8)informationThere are no valid display names found for the code http://loinc.org#9268-4 for language(s) 'de-DE'. The display is 'Glasgow coma score motor' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[1]​.value​.ofType(CodeableConcept)​.coding[0]​.display (l75​/c8)informationThere are no valid display names found for the code http://loinc.org#LA6567-7 for language(s) 'de-DE'. The display is 'Obeys commands' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[2]​.code​.coding[0]​.display (l86​/c8)informationThere are no valid display names found for the code http://loinc.org#9267-6 for language(s) 'de-DE'. The display is 'Glasgow coma score eye opening' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[2]​.value​.ofType(CodeableConcept)​.coding[0]​.display (l95​/c8)warningWrong Display Name 'Eye opening spontaneously' for http://loinc.org#LA6556-0. There are no valid display names found for language(s) 'de-DE'. Default display is 'Eyes open spontaneously' (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_ERRISiKGCS

input/resources/Observation-ISiKGCSMinExample.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.code​.coding[0]​.display (l25​/c4)informationThere are no valid display names found for the code http://loinc.org#9269-2 for language(s) 'de-DE'. The display is 'Glasgow coma score total' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[0]​.code​.coding[0]​.display (l36​/c8)informationThere are no valid display names found for the code http://loinc.org#9270-0 for language(s) 'de-DE'. The display is 'Glasgow coma score verbal' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[0]​.value​.ofType(CodeableConcept)​.coding[0]​.display (l45​/c8)informationThere are no valid display names found for the code http://loinc.org#LA6557-8 for language(s) 'de-DE'. The display is 'No verbal response (>2 yrs); no vocal response (<=2 yrs)' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[1]​.code​.coding[0]​.display (l56​/c8)informationThere are no valid display names found for the code http://loinc.org#9268-4 for language(s) 'de-DE'. The display is 'Glasgow coma score motor' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[1]​.value​.ofType(CodeableConcept)​.coding[0]​.display (l65​/c8)informationThere are no valid display names found for the code http://loinc.org#LA6562-8 for language(s) 'de-DE'. The display is 'No motor response' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[2]​.code​.coding[0]​.display (l76​/c8)informationThere are no valid display names found for the code http://loinc.org#9267-6 for language(s) 'de-DE'. The display is 'Glasgow coma score eye opening' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation​.component[2]​.value​.ofType(CodeableConcept)​.coding[0]​.display (l85​/c8)informationThere are no valid display names found for the code http://loinc.org#LA6553-7 for language(s) 'de-DE'. The display is 'No eye opening' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiKGCS
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer--

input/resources/Observation-Intrakranieller-Druck-ICP.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.code​.coding[0]​.display (l19​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#250844005 for language(s) 'de-DE'. The display is 'Intracranial pressure' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKSD MII ICU Intrakranieller Druck ICP
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer--

input/resources/Parameters-exp-params.json Show Validation Information (1)


input/resources/Patient-DorisQuelle.json Show Validation Information (1)

PathSeverityMessageValidating
Patient.identifier[0].system (l19/c59)warningNo definition could be found for URL value 'https://fhir.krankenhaus.example/sid/PID' Type_Specific_Checks_DT_URL_ResolveISiKPatient

input/resources/Patient-DorisZiel.json Show Validation Information (1)

PathSeverityMessageValidating
Patient.identifier[0].system (l19/c59)warningNo definition could be found for URL value 'https://fhir.krankenhaus.example/sid/PID' Type_Specific_Checks_DT_URL_ResolveISiKPatient

input/resources/Patient-IsikPatientTemplate.json Show Validation Information (1)

PathSeverityMessageValidating
Patient.identifier[1].value (l52/c8)warningConstraint failed: kvid-1: 'Der unveränderliche Teil der KVID muss 10-stellig sein und mit einem Großbuchstaben anfangen (matches('^[A-Z][0-9]{9}$'))' (defined in http://fhir.de/StructureDefinition/identifier-kvid-10) http://fhir.de/StructureDefinition/identifier-kvid-10#kvid-1ISiKPatient
Patient​.name[0]​.family​.extension[0] (l81​/c12)Slicing InformationThis element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/humanname-de-basis|1.6.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKPatient
Patient​.name[0]​.family​.extension[0] (l81​/c12)Slicing InformationThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKPatient
Patient.gender.extension[0] (l176/c8)Slicing InformationThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKPatient
Patient​.birthDate​.extension[0] (l184​/c8)Slicing InformationThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKPatient
Patient​.address[0]​.extension[0] (l103​/c10)Slicing InformationThis element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.6.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKPatient
Patient​.address[0]​.line[0]​.extension[0] (l120​/c14)Slicing InformationThis element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.6.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKPatient
Patient​.address[0]​.country​.extension[0] (l111​/c12)Slicing InformationThis element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.6.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKPatient
Patient​.address[0]​.extension[0] (l103​/c10)Slicing InformationThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKPatient
Patient​.address[0]​.line[0]​.extension[0] (l120​/c14)Slicing InformationThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKPatient
Patient​.address[0]​.country​.extension[0] (l111​/c12)Slicing InformationThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_ISiKPatient

input/resources/Patient-PatientinMinimal.json Show Validation Information (1)

PathSeverityMessageValidating
Patient.identifier[0].system (l19/c59)warningNo definition could be found for URL value 'https://fhir.krankenhaus.example/sid/PID' Type_Specific_Checks_DT_URL_ResolveISiKPatient

input/resources/Patient-PatientinMusterfrau.json Show Validation Information (1)

PathSeverityMessageValidating
Patient.identifier[0].system (l19/c59)warningNo definition could be found for URL value 'https://fhir.krankenhaus.example/sid/PID' Type_Specific_Checks_DT_URL_ResolveISiKPatient
Patient​.identifier[2]​.type​.coding[0] (l36​/c8)warningThe concept 'PKV' has a status of inactive and its use should be reviewed INACTIVE_CONCEPT_FOUNDISiKPatient
Patient​.identifier[2]​.type​.coding[0] (l36​/c8)warningThe concept 'PKV' has a status of retired and its use should be reviewed INACTIVE_CONCEPT_FOUNDISiKPatient

input/resources/Patient-PatientinNormal.json Show Validation Information (1)

PathSeverityMessageValidating
Patient.identifier[0].system (l19/c59)warningNo definition could be found for URL value 'https://fhir.krankenhaus.example/sid/PID' Type_Specific_Checks_DT_URL_ResolveISiKPatient

input/resources/Patient-SZ1Patient.json Show Validation Information (1)

PathSeverityMessageValidating
Patient.identifier[0].system (l19/c63)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/Patienten' Type_Specific_Checks_DT_URL_ResolveISiKPatient

input/resources/Patient-SZ2Patient.json Show Validation Information (1)

PathSeverityMessageValidating
Patient.identifier[0].system (l19/c63)warningNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/Patienten' Type_Specific_Checks_DT_URL_ResolveISiKPatient

input/resources/Patient-isik-patient-156722.json Show Validation Information (1)

PathSeverityMessageValidating
Patient.identifier[0].system (l19/c62)warningNo definition could be found for URL value 'https://example-krankenhaus.de/fhir/sid/pid' Type_Specific_Checks_DT_URL_ResolveISiKPatient

input/resources/Procedure-Appendektomie.json Show Validation Information (1)

PathSeverityMessageValidating
Procedure​.category​.coding[0]​.display (l16​/c4)warningWrong Display Name 'Chirurgische Prozedur' for http://snomed.info/sct#387713003. There are no valid display names found for language(s) 'de-DE'. Default display is 'Surgical procedure' (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_ERRISiKProzedur
Procedure​.category​.coding[0]​.display (l18​/c8)warningWrong Display Name 'Chirurgische Prozedur' for http://snomed.info/sct#387713003. Valid display is 'Surgical procedure' (for the language(s) 'de-DE') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_ofISiKProzedur
Procedure.category.coding[0] (l18/c8)warningWrong Display Name 'Chirurgische Prozedur' for http://snomed.info/sct#387713003. Valid display is 'Surgical procedure' (for the language(s) 'de-DE') (from server, see log, or see the servers logic) ISiKProzedur
Procedure​.code​.coding[0]​.display (l25​/c4)warningWrong Display Name 'Appendektomie' for http://snomed.info/sct#80146002. There are no valid display names found for language(s) 'de-DE'. Default display is 'Appendectomy' (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_ERRISiKProzedur
Procedure​.code​.coding[1]​.system (l25​/c4)warningA definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' version '2024' could not be found, so the code cannot be validated. No versions of this code system are known (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM_VERSION_NONEISiKProzedur
Procedure.code.coding[0] (l27/c8)warningWrong Display Name 'Appendektomie' for http://snomed.info/sct#80146002. There are no valid display names found for language(s) 'de-DE'. Default display is 'Appendectomy' (from server, see log, or see the servers logic) ISiKProzedur

input/resources/Procedure-ExampleOrganVentilationMode20200311.json Show Validation Information (1)

PathSeverityMessageValidating
Procedure​.code​.coding[0]​.display (l18​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#243142003 for language(s) 'de-DE'. The display is 'Dual pressure spontaneous ventilation support' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiK Prozedur Beatmung

input/resources/Procedure-ExampleOrganVentilationModeASV.json Show Validation Information (1)

PathSeverityMessageValidating
Procedure​.code​.coding[0]​.display (l18​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#1186620002 for language(s) 'de-DE'. The display is 'Minimum minute volume ventilation' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiK Prozedur Beatmung

input/resources/Procedure-ExampleOrganVentilationModeBiLev.json Show Validation Information (1)

PathSeverityMessageValidating
Procedure​.code​.coding[0]​.display (l18​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#1186618000 for language(s) 'de-DE'. The display is 'Bilevel artificial ventilation' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiK Prozedur Beatmung

input/resources/Procedure-ExampleOrganVentilationModeNIV.json Show Validation Information (1)

PathSeverityMessageValidating
Procedure​.code​.coding[0]​.display (l18​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#428311008 for language(s) 'de-DE'. The display is 'Non-invasive ventilation' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiK Prozedur Beatmung

input/resources/Procedure-ExampleOrganVentilationModePCMod.json Show Validation Information (1)

PathSeverityMessageValidating
Procedure​.code​.coding[0]​.display (l18​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#1149092001 for language(s) 'de-DE'. The display is 'Positive pressure ventilation' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiK Prozedur Beatmung

input/resources/Procedure-ExampleOrganVentilationModePSIMV.json Show Validation Information (1)

PathSeverityMessageValidating
Procedure​.code​.coding[0]​.display (l18​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#1186622005 for language(s) 'de-DE'. The display is 'Synchronized intermittent mandatory ventilation - pressure-control pressure-support inflation' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiK Prozedur Beatmung

input/resources/Procedure-ExampleOrganVentilationModeSPNMod.json Show Validation Information (1)

PathSeverityMessageValidating
Procedure​.code​.coding[0]​.display (l18​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#243141005 for language(s) 'de-DE'. The display is 'Mechanically assisted spontaneous ventilation' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiK Prozedur Beatmung

input/resources/Procedure-ExampleOrganVentilationModeStMod.json Show Validation Information (1)

PathSeverityMessageValidating
Procedure​.code​.coding[0]​.display (l18​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#1186618000 for language(s) 'de-DE'. The display is 'Bilevel artificial ventilation' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiK Prozedur Beatmung

input/resources/Procedure-ExampleOrganVentilationModenC.json Show Validation Information (1)

PathSeverityMessageValidating
Procedure​.code​.coding[0]​.display (l18​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#229312009 for language(s) 'de-DE'. The display is 'Nasal ventilation therapy' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiK Prozedur Beatmung

input/resources/Procedure-ReanimationBeispiel.json Show Validation Information (1)

PathSeverityMessageValidating
Procedure​.category​.coding[0]​.display (l9​/c4)informationThere are no valid display names found for the code http://snomed.info/sct#439569004 for language(s) 'de-DE'. The display is 'Resuscitation (procedure)' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKISiK Prozedur Reanimation
Procedure​.code​.coding[0]​.system (l25​/c4)warningA definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000274103/version/20251115' could not be found, so the code cannot be validated. Valid versions: http://snomed.info/sct/11000146104/version/20240930, http://snomed.info/sct/2011000195101/version/20230607, http://snomed.info/sct/554471000005108/version/20260331, http://snomed.info/sct/731000124108/version/20230301, http://snomed.info/sct/731000124108/version/20240301, http://snomed.info/sct/731000124108/version/20250901, http://snomed.info/sct/827022005/version/20241216, http://snomed.info/sct/83821000000107/version/20230412, http://snomed.info/sct/900000000000207008/version/20240201, http://snomed.info/sct/900000000000207008/version/20250201 and http://snomed.info/xsct/900000000000207008/version/20250814 (from https://tx.fhir.org/r4, see log) UNKNOWN_CODESYSTEM_VERSIONISiK Prozedur Reanimation
Procedure.code.coding[1] (l33/c8)errorThe code provided (http://fhir.de/CodeSystem/bfarm/ops#8-771) was not found in the value set 'ProzedurenReanimationCodesOPS' (https://gematik.de/fhir/isik/ValueSet/ProzedurenReanimationCodesOPS|6.0.0), and a code from this value set is required: Cannot invoke "String.length()" because "prefix" is null

Editor's Comment: There are missing dependencies in the IG-Publisher validation, but there is no error during manual validation (from server, see log, or see the servers logic) Terminology_TX_Confirm_4a
ISiK Prozedur Reanimation

input/resources/SearchParameter-Encounter-date-start.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource SearchParameter/Encounter-date-start could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/SearchParameter-Encounter-end-date.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource SearchParameter/Encounter-end-date could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-ExtensionISiKCapabilityStatementImportsExpectation.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[4]​.binding​.valueSet (l1​/c18510)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/conformance-expectation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '2.0.0', found versions: 0.3.0 (from hl7.terminology.r4#5.0.0), 1.0.0 (from hl7.terminology.r4#6.5.0), 2.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/conformance-expectation' to 'http://terminology.hl7.org/ValueSet/conformance-expectation|2.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[3]​.binding​.valueSet (l1​/c19688)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/conformance-expectation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '2.0.0', found versions: 0.3.0 (from hl7.terminology.r4#5.0.0), 1.0.0 (from hl7.terminology.r4#6.5.0), 2.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/conformance-expectation' to 'http://terminology.hl7.org/ValueSet/conformance-expectation|2.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
ResourceinformationThe resource StructureDefinition/ExtensionISiKCapabilityStatementImportsExpectation could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-ExtensionISiKRehaEntlassung.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ExtensionISiKRehaEntlassung could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/ExtensionISiKRehaEntlassung')warningThe Implementation Guide contains no examples for this extension --

input/resources/StructureDefinition-ISiKCoding.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ISiKCoding could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/ISiKCoding')warningThe Implementation Guide contains no examples for this data type profile --

input/resources/StructureDefinition-ISiKGCS.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.baseDefinition (l1​/c131248)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/observation-de-score-gcs'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/observation-de-score-gcs' to 'http://fhir.de/StructureDefinition/observation-de-score-gcs|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[12]​.binding​.extension[0] (l1​/c149651)informationThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead' MSG_DEPENDS_ON_DEPRECATED_NOTEStructureDefinition
StructureDefinition​.snapshot​.element[40]​.constraint[1]​.source (l1​/c198384)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/observation-de-score-gcs'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/observation-de-score-gcs' to 'http://fhir.de/StructureDefinition/observation-de-score-gcs|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[104]​.binding​.valueSet (l1​/c293228)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/glasgow-coma-score-eye'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/glasgow-coma-score-eye' to 'http://fhir.de/ValueSet/glasgow-coma-score-eye|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[128]​.binding​.valueSet (l1​/c325894)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/glasgow-coma-score-motor'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/glasgow-coma-score-motor' to 'http://fhir.de/ValueSet/glasgow-coma-score-motor|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[152]​.binding​.valueSet (l1​/c358594)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/glasgow-coma-score-verbal'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/glasgow-coma-score-verbal' to 'http://fhir.de/ValueSet/glasgow-coma-score-verbal|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[21]​.slicing​.discriminator[0] (l1​/c165542)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[26]​.slicing​.discriminator[0] (l1​/c172469)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[28]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
StructureDefinition​.snapshot​.element[70]​.slicing​.discriminator[0] (l1​/c245325)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot (l1​/c377428)warningThe slice 'IEEE11073' on path 'Observation.code.coding' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true --
ResourceinformationThe resource StructureDefinition/ISiKGCS could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[16]​.type[0]​.profile[0] (l1​/c283456)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Aufnahmegrund'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Aufnahmegrund' to 'http://fhir.de/StructureDefinition/Aufnahmegrund|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[23]​.binding​.valueSet (l1​/c291623)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/AufnahmegrundErsteUndZweiteStelle'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/AufnahmegrundErsteUndZweiteStelle' to 'http://fhir.de/ValueSet/dkgev/AufnahmegrundErsteUndZweiteStelle|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[28]​.binding​.valueSet (l1​/c296729)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/AufnahmegrundDritteStelle'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/AufnahmegrundDritteStelle' to 'http://fhir.de/ValueSet/dkgev/AufnahmegrundDritteStelle|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[33]​.binding​.valueSet (l1​/c301835)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/AufnahmegrundVierteStelle'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/AufnahmegrundVierteStelle' to 'http://fhir.de/ValueSet/dkgev/AufnahmegrundVierteStelle|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[61]​.binding​.valueSet (l1​/c338477)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/EncounterStatusDe'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/EncounterStatusDe' to 'http://fhir.de/ValueSet/EncounterStatusDe|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[73]​.binding​.valueSet (l1​/c354578)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode' to 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode|3.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[76]​.binding​.valueSet (l1​/c358747)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/kontaktebene-de'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/kontaktebene-de' to 'http://fhir.de/ValueSet/kontaktebene-de|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[104]​.binding​.valueSet (l1​/c393183)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel' to 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[105]​.binding​.valueSet (l1​/c394459)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert' to 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[107]​.binding​.valueSet (l1​/c397003)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActPriority'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActPriority' to 'http://terminology.hl7.org/ValueSet/v3-ActPriority|3.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[148]​.binding​.valueSet (l1​/c454045)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/DiagnoseTyp'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/DiagnoseTyp' to 'http://fhir.de/ValueSet/DiagnoseTyp|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[149]​.binding​.valueSet (l1​/c455245)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/Diagnosesubtyp'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/Diagnosesubtyp' to 'http://fhir.de/ValueSet/Diagnosesubtyp|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[170]​.type[0]​.profile[0] (l1​/c481756)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Wahlleistung'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Wahlleistung' to 'http://fhir.de/StructureDefinition/Wahlleistung|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[174]​.binding​.valueSet (l1​/c487609)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass' to 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[175]​.binding​.valueSet (l1​/c488742)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0092'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#6.5.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0092' to 'http://terminology.hl7.org/ValueSet/v2-0092|3.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[183]​.type[0]​.profile[0] (l1​/c497455)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Entlassungsgrund'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Entlassungsgrund' to 'http://fhir.de/StructureDefinition/Entlassungsgrund|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[6]​.type[0]​.profile[0] (l1​/c659645)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Aufnahmegrund'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Aufnahmegrund' to 'http://fhir.de/StructureDefinition/Aufnahmegrund|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[21]​.binding​.valueSet (l1​/c665034)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/EncounterStatusDe'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/EncounterStatusDe' to 'http://fhir.de/ValueSet/EncounterStatusDe|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[24]​.binding​.valueSet (l1​/c667813)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/kontaktebene-de'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/kontaktebene-de' to 'http://fhir.de/ValueSet/kontaktebene-de|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[34]​.binding​.valueSet (l1​/c670250)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel' to 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[35]​.binding​.valueSet (l1​/c670768)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert' to 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[49]​.binding​.valueSet (l1​/c677087)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/DiagnoseTyp'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/DiagnoseTyp' to 'http://fhir.de/ValueSet/DiagnoseTyp|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[50]​.binding​.valueSet (l1​/c677529)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/Diagnosesubtyp'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/Diagnosesubtyp' to 'http://fhir.de/ValueSet/Diagnosesubtyp|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[59]​.type[0]​.profile[0] (l1​/c681124)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Wahlleistung'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Wahlleistung' to 'http://fhir.de/StructureDefinition/Wahlleistung|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[60]​.binding​.valueSet (l1​/c681549)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass' to 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[62]​.type[0]​.profile[0] (l1​/c682261)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Entlassungsgrund'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Entlassungsgrund' to 'http://fhir.de/StructureDefinition/Entlassungsgrund|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[12]​.slicing​.discriminator[0] (l1​/c661406)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[15]​.slicing​.discriminator[0] (l1​/c662262)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[23]​.slicing​.discriminator[0] (l1​/c665937)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[33]​.slicing​.discriminator[0] (l1​/c669755)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[48]​.slicing​.discriminator[0] (l1​/c676596)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[64]​.slicing​.discriminator[0] (l1​/c683009)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[0]​.constraint[12] (l1​/c265710)warningISiK-enc-8: The left side is inherently a collection, and so the expression 'coding.code != 'billing'' may fail or return false if there is more than one item in the content being evaluated FHIRPATH_COLLECTION_STATUS_OPERATION_LEFT--
StructureDefinition​.snapshot​.element[39]​.slicing​.discriminator[0] (l1​/c309551)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[47]​.slicing​.discriminator[0] (l1​/c319478)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[75]​.slicing​.discriminator[0] (l1​/c355391)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[103]​.slicing​.discriminator[0] (l1​/c390966)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[147]​.slicing​.discriminator[0] (l1​/c451832)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[187]​.slicing​.discriminator[0] (l1​/c502289)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/ISiKKontaktGesundheitseinrichtung could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-ISiKLaboruntersuchung.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[97]​.binding​.valueSet (l1​/c323946)errorA definition could not be found for Canonical URL 'http://hl7.org/fhir/uv/ips/ValueSet/results-coded-values-laboratory-uv-ips' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVEStructureDefinition
StructureDefinition​.differential​.element[36]​.binding​.valueSet (l1​/c447795)errorA definition could not be found for Canonical URL 'http://hl7.org/fhir/uv/ips/ValueSet/results-coded-values-laboratory-uv-ips' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVEStructureDefinition
StructureDefinition​.differential​.element[5]​.slicing​.discriminator[0] (l1​/c436594)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[12]​.slicing​.discriminator[0] (l1​/c439227)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[16]​.slicing​.discriminator[0] (l1​/c441002)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[17]​.slicing​.discriminator[0] (l1​/c214586)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[46]​.slicing​.discriminator[0] (l1​/c252245)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[52]​.slicing​.discriminator[0] (l1​/c260349)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[60]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
StructureDefinition​.snapshot (l1​/c433714)warningThe slice 'laborbereich' on path 'Observation.category' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true --
StructureDefinition​.snapshot (l1​/c433714)warningThe slice 'valueCodeableConcept' on path 'Observation.value[x]' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true --
ResourceinformationThe resource StructureDefinition/ISiKLaboruntersuchung could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition.text.diverrorHyperlink 'http://hl7.org/fhir/uv/ips/ValueSet/results-coded-values-laboratory-uv-ips' at 'div/table/tr/td/a' for 'http://hl7.org/fhir/uv/ips/ValueSet/results-coded-values-laboratory-uv-ips' does not resolve --

input/resources/StructureDefinition-ISiKLaboruntersuchungSerumnatrium.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[90]​.binding​.valueSet (l1​/c151346)errorA definition could not be found for Canonical URL 'http://hl7.org/fhir/uv/ips/ValueSet/results-coded-values-laboratory-uv-ips' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVEStructureDefinition
StructureDefinition​.snapshot​.element[17]​.slicing​.discriminator[0] (l1​/c50567)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[46]​.slicing​.discriminator[0] (l1​/c88226)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[52]​.slicing​.discriminator[0] (l1​/c96330)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[53]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
StructureDefinition​.snapshot (l1​/c261342)warningThe slice 'laborbereich' on path 'Observation.category' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true --
StructureDefinition​.snapshot (l1​/c261342)warningThe slice 'valueCodeableConcept' on path 'Observation.value[x]' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true --
ResourceinformationThe resource StructureDefinition/ISiKLaboruntersuchungSerumnatrium could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-ISiKLoincCoding.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ISiKLoincCoding could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-ISiKPatient.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[18]​.type[0]​.profile[0] (l1​/c232573)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-kvid-10'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-kvid-10' to 'http://fhir.de/StructureDefinition/identifier-kvid-10|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[22]​.constraint[1]​.source (l1​/c238650)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-kvid-10'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-kvid-10' to 'http://fhir.de/StructureDefinition/identifier-kvid-10|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[24]​.constraint[1]​.source (l1​/c241788)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-kvid-10'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-kvid-10' to 'http://fhir.de/StructureDefinition/identifier-kvid-10|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[25]​.mapping[2]​.map (l1​/c243642)informationThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security risk SECURITY_STRING_CONTENT_WARNINGStructureDefinition
StructureDefinition​.snapshot​.element[27]​.type[0]​.profile[0] (l1​/c246615)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-pid'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-pid' to 'http://fhir.de/StructureDefinition/identifier-pid|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[31]​.binding​.valueSet (l1​/c252390)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/identifier-type-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/identifier-type-de-basis' to 'http://fhir.de/ValueSet/identifier-type-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[34]​.mapping[2]​.map (l1​/c256947)informationThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security risk SECURITY_STRING_CONTENT_WARNINGStructureDefinition
StructureDefinition​.snapshot​.element[36]​.type[0]​.profile[0] (l1​/c260477)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-pkv'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-pkv' to 'http://fhir.de/StructureDefinition/identifier-pkv|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[36]​.pattern​.ofType(Identifier)​.type​.coding[0] (l1​/c260598)warningThe concept 'PKV' has a status of inactive and its use should be reviewed INACTIVE_CONCEPT_FOUNDStructureDefinition
StructureDefinition​.snapshot​.element[36]​.pattern​.ofType(Identifier)​.type​.coding[0] (l1​/c260598)warningThe concept 'PKV' has a status of retired and its use should be reviewed INACTIVE_CONCEPT_FOUNDStructureDefinition
StructureDefinition​.snapshot​.element[40]​.pattern​.ofType(CodeableConcept)​.coding[0] (l1​/c265601)warningThe concept 'PKV' has a status of inactive and its use should be reviewed INACTIVE_CONCEPT_FOUNDStructureDefinition
StructureDefinition​.snapshot​.element[40]​.pattern​.ofType(CodeableConcept)​.coding[0] (l1​/c265601)warningThe concept 'PKV' has a status of retired and its use should be reviewed INACTIVE_CONCEPT_FOUNDStructureDefinition
StructureDefinition​.snapshot​.element[40]​.binding​.valueSet (l1​/c266264)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/identifier-type-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/identifier-type-de-basis' to 'http://fhir.de/ValueSet/identifier-type-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[43]​.mapping[2]​.map (l1​/c270436)informationThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security risk SECURITY_STRING_CONTENT_WARNINGStructureDefinition
StructureDefinition​.snapshot​.element[49]​.type[0]​.profile[0] (l1​/c280717)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-iknr'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-iknr' to 'http://fhir.de/StructureDefinition/identifier-iknr|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[53]​.binding​.valueSet (l1​/c287096)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/identifier-type-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/identifier-type-de-basis' to 'http://fhir.de/ValueSet/identifier-type-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[55]​.constraint[1]​.source (l1​/c289698)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-iknr'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-iknr' to 'http://fhir.de/StructureDefinition/identifier-iknr|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[56]​.mapping[2]​.map (l1​/c291600)informationThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security risk SECURITY_STRING_CONTENT_WARNINGStructureDefinition
StructureDefinition​.snapshot​.element[61]​.type[0]​.profile[0] (l1​/c298717)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-de-basis' to 'http://fhir.de/StructureDefinition/humanname-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[69]​.type[0]​.profile[0] (l1​/c308034)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-namenszusatz'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-namenszusatz' to 'http://fhir.de/StructureDefinition/humanname-namenszusatz|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[70]​.type[0]​.profile[0] (l1​/c309337)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-name'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-name' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-name|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[71]​.type[0]​.profile[0] (l1​/c310779)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[72]​.type[0]​.extension[1] (l1​/c311943)informationThe extension http://hl7.org/fhir/StructureDefinition/regex|5.3.0 is deprecated with the note: 'This was deprecated in favor of using a constraint on the element using FHIRPath, since constraints allow for the provision of a human readable message associated with the regex' MSG_DEPENDS_ON_DEPRECATED_NOTEStructureDefinition
StructureDefinition​.snapshot​.element[77]​.type[0]​.profile[0] (l1​/c316973)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier' to 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[81]​.binding​.valueSet (l1​/c321165)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/name-part-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '4.0.1', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/name-part-qualifier' to 'http://hl7.org/fhir/ValueSet/name-part-qualifier|4.0.1' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[84]​.mapping[2]​.map (l1​/c324203)informationThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security risk SECURITY_STRING_CONTENT_WARNINGStructureDefinition
StructureDefinition​.snapshot​.element[85]​.type[0]​.profile[0] (l1​/c324899)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-de-basis' to 'http://fhir.de/StructureDefinition/humanname-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[93]​.type[0]​.profile[0] (l1​/c334273)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-namenszusatz'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-namenszusatz' to 'http://fhir.de/StructureDefinition/humanname-namenszusatz|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[94]​.type[0]​.profile[0] (l1​/c335583)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-name'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-name' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-name|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[95]​.type[0]​.profile[0] (l1​/c337032)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[101]​.type[0]​.profile[0] (l1​/c343204)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier' to 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[104]​.mapping[2]​.map (l1​/c346925)informationThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security risk SECURITY_STRING_CONTENT_WARNINGStructureDefinition
StructureDefinition​.snapshot​.element[116]​.type[0]​.profile[0] (l1​/c359898)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/gender-amtlich-de'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/gender-amtlich-de' to 'http://fhir.de/StructureDefinition/gender-amtlich-de|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[121]​.type[0]​.profile[0] (l1​/c364225)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/data-absent-reason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/data-absent-reason' to 'http://hl7.org/fhir/StructureDefinition/data-absent-reason|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[129]​.type[0]​.profile[0] (l1​/c372405)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[132]​.type[0]​.profile[0] (l1​/c376226)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[139]​.type[0]​.profile[0] (l1​/c386621)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[140]​.type[0]​.profile[0] (l1​/c388151)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[141]​.type[0]​.profile[0] (l1​/c389948)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[142]​.type[0]​.profile[0] (l1​/c391429)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[146]​.binding​.valueSet (l1​/c395286)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/iso/bundeslaender'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/iso/bundeslaender' to 'http://fhir.de/ValueSet/iso/bundeslaender|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[151]​.type[0]​.profile[0] (l1​/c400658)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString' to 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[151]​.example[0]​.value​.ofType(Coding)​.display (l1​/c400802)warningWrong Display Name 'Deutschland' for urn:iso:std:iso:3166#DE. There are no valid display names found for language(s) 'de-DE'. Default display is 'Germany' (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_ERRStructureDefinition
StructureDefinition​.snapshot​.element[157]​.mapping[2]​.map (l1​/c408495)informationThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security risk SECURITY_STRING_CONTENT_WARNINGStructureDefinition
StructureDefinition​.snapshot​.element[158]​.type[0]​.profile[0] (l1​/c409204)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[161]​.type[0]​.profile[0] (l1​/c413361)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[168]​.type[0]​.profile[0] (l1​/c423266)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[169]​.type[0]​.profile[0] (l1​/c424395)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[170]​.type[0]​.profile[0] (l1​/c425778)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[171]​.type[0]​.profile[0] (l1​/c427231)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[175]​.binding​.valueSet (l1​/c431071)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/iso/bundeslaender'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/iso/bundeslaender' to 'http://fhir.de/ValueSet/iso/bundeslaender|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[180]​.type[0]​.profile[0] (l1​/c436398)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString' to 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[180]​.example[0]​.value​.ofType(Coding)​.display (l1​/c436542)warningWrong Display Name 'Deutschland' for urn:iso:std:iso:3166#DE. There are no valid display names found for language(s) 'de-DE'. Default display is 'Germany' (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_ERRStructureDefinition
StructureDefinition​.snapshot​.element[186]​.mapping[2]​.map (l1​/c444181)informationThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security risk SECURITY_STRING_CONTENT_WARNINGStructureDefinition
StructureDefinition​.differential​.element[6]​.type[0]​.profile[0] (l1​/c493431)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-kvid-10'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-kvid-10' to 'http://fhir.de/StructureDefinition/identifier-kvid-10|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[10]​.type[0]​.profile[0] (l1​/c495642)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-pid'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-pid' to 'http://fhir.de/StructureDefinition/identifier-pid|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[14]​.type[0]​.profile[0] (l1​/c498248)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-pkv'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-pkv' to 'http://fhir.de/StructureDefinition/identifier-pkv|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[14]​.pattern​.ofType(Identifier)​.type​.coding[0] (l1​/c498369)warningThe concept 'PKV' has a status of inactive and its use should be reviewed INACTIVE_CONCEPT_FOUNDStructureDefinition
StructureDefinition​.differential​.element[14]​.pattern​.ofType(Identifier)​.type​.coding[0] (l1​/c498369)warningThe concept 'PKV' has a status of retired and its use should be reviewed INACTIVE_CONCEPT_FOUNDStructureDefinition
StructureDefinition​.differential​.element[24]​.type[0]​.profile[0] (l1​/c501962)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-de-basis' to 'http://fhir.de/StructureDefinition/humanname-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[34]​.type[0]​.profile[0] (l1​/c504906)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-de-basis' to 'http://fhir.de/StructureDefinition/humanname-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[47]​.type[0]​.profile[0] (l1​/c509216)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/gender-amtlich-de'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/gender-amtlich-de' to 'http://fhir.de/StructureDefinition/gender-amtlich-de|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[50]​.type[0]​.profile[0] (l1​/c510217)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/data-absent-reason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/data-absent-reason' to 'http://hl7.org/fhir/StructureDefinition/data-absent-reason|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[54]​.type[0]​.profile[0] (l1​/c511554)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[65]​.type[0]​.profile[0] (l1​/c516806)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[5]​.slicing​.discriminator[0] (l1​/c491900)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[23]​.slicing​.discriminator[0] (l1​/c501055)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[53]​.slicing​.discriminator[0] (l1​/c511198)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[17]​.slicing​.discriminator[0] (l1​/c230143)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[27]​.pattern​.ofType(Identifier)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
StructureDefinition​.snapshot​.element[60]​.slicing​.discriminator[0] (l1​/c296851)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[128]​.slicing​.discriminator[0] (l1​/c371065)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[129]​.pattern​.ofType(Address)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
StructureDefinition​.snapshot​.element[158]​.pattern​.ofType(Address)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
StructureDefinition​.snapshot (l1​/c489668)warningThe slice 'Versichertennummer_PKV' on path 'Patient.identifier' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true --
ResourceinformationThe resource StructureDefinition/ISiKPatient could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-ISiKProzedur.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[16]​.type[0]​.profile[0] (l1​/c95899)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum' to 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[35]​.type[0]​.profile[0] (l1​/c123511)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[38]​.type[0]​.profile[0] (l1​/c127316)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/seitenlokalisation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/seitenlokalisation' to 'http://fhir.de/StructureDefinition/seitenlokalisation|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[41]​.constraint[1]​.source (l1​/c131487)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[76]​.type[0]​.profile[0] (l1​/c181090)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[6]​.type[0]​.profile[0] (l1​/c203661)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum' to 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[13]​.type[0]​.profile[0] (l1​/c207693)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[25]​.type[0]​.profile[0] (l1​/c213791)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[9]​.slicing​.discriminator[0] (l1​/c205076)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[12]​.slicing​.discriminator[0] (l1​/c206883)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[28]​.slicing​.discriminator[0] (l1​/c112427)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[34]​.slicing​.discriminator[0] (l1​/c121339)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/ISiKProzedur could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-ISiKProzedurBeatmung.json Show Validation Information (1)

PathSeverityMessageValidating
ISiK Prozedur Beatmung​.coding​.Procedure​.code​.codingwarningUnable to check if https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-code-procedure-beatmung-snomed is a proper subset of https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT - value set is too large to check --
StructureDefinition​.snapshot​.element[16]​.type[0]​.profile[0] (l1​/c45230)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum' to 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[35]​.type[0]​.profile[0] (l1​/c72916)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[38]​.type[0]​.profile[0] (l1​/c76721)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/seitenlokalisation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/seitenlokalisation' to 'http://fhir.de/StructureDefinition/seitenlokalisation|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[41]​.constraint[1]​.source (l1​/c80892)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[76]​.type[0]​.profile[0] (l1​/c130570)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[28]​.slicing​.discriminator[0] (l1​/c61758)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[34]​.slicing​.discriminator[0] (l1​/c70744)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/ISiKProzedurBeatmung could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-ISiKProzedurReanimation.json Show Validation Information (1)

PathSeverityMessageValidating
ISiK Prozedur Reanimation​.coding​.Procedure​.code​.codingwarningUnable to check if https://gematik.de/fhir/isik/ValueSet/ProzedurenReanimationCodesSCT is a proper subset of https://gematik.de/fhir/isik/ValueSet/ProzedurenCodesSCT - value set is too large to check --
StructureDefinition​.snapshot​.element[16]​.type[0]​.profile[0] (l1​/c52601)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum' to 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[29]​.pattern​.ofType(Coding)​.display (l1​/c71287)informationThere are no valid display names found for the code http://snomed.info/sct#439569004 for language(s) 'de-DE'. The display is 'Resuscitation (procedure)' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKStructureDefinition
StructureDefinition​.snapshot​.element[29]​.pattern​.ofType(Coding) (l1​/c71287)warningThere are no valid display names found for the code http://snomed.info/sct#439569004 for language(s) 'de-DE'. The display is 'Resuscitation (procedure)' which is a valid display for the default language (for 'http://snomed.info/sct#439569004') (from server, see log, or see the servers logic) Terminology_PassThrough_TX_MessageStructureDefinition
StructureDefinition​.snapshot​.element[35]​.type[0]​.profile[0] (l1​/c80322)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[38]​.type[0]​.profile[0] (l1​/c84307)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/seitenlokalisation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/seitenlokalisation' to 'http://fhir.de/StructureDefinition/seitenlokalisation|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[41]​.constraint[1]​.source (l1​/c88478)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[76]​.type[0]​.profile[0] (l1​/c138144)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[1]​.pattern​.ofType(Coding)​.display (l1​/c157885)informationThere are no valid display names found for the code http://snomed.info/sct#439569004 for language(s) 'de-DE'. The display is 'Resuscitation (procedure)' which is a valid display for the default language (from https://tx.fhir.org/r4, see log, or see the servers logic) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OKStructureDefinition
StructureDefinition​.differential​.element[1]​.pattern​.ofType(Coding) (l1​/c157885)warningThere are no valid display names found for the code http://snomed.info/sct#439569004 for language(s) 'de-DE'. The display is 'Resuscitation (procedure)' which is a valid display for the default language (for 'http://snomed.info/sct#439569004') (from server, see log, or see the servers logic) Terminology_PassThrough_TX_MessageStructureDefinition
StructureDefinition​.snapshot​.element[28]​.slicing​.discriminator[0] (l1​/c69129)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[34]​.slicing​.discriminator[0] (l1​/c78150)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/ISiKProzedurReanimation could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-ISiKSnomedCTCoding.json Show Validation Information (1)

PathSeverityMessageValidating
ResourceinformationThe resource StructureDefinition/ISiKSnomedCTCoding could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-ISiKStandort.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[18]​.type[0]​.profile[0] (l1​/c66976)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-standortnummer'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-standortnummer' to 'http://fhir.de/StructureDefinition/identifier-standortnummer|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[18]​.pattern​.ofType(Identifier)​.system (l1​/c67051)warningNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer' Type_Specific_Checks_DT_URL_ResolveStructureDefinition
StructureDefinition​.snapshot​.element[20]​.binding​.valueSet (l1​/c69802)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0116'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#6.5.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0116' to 'http://terminology.hl7.org/ValueSet/v2-0116|3.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[25]​.binding​.valueSet (l1​/c75289)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType' to 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType|3.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.snapshot​.element[27]​.type[0]​.profile[0] (l1​/c76644)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[6]​.type[0]​.profile[0] (l1​/c101832)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-standortnummer'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-standortnummer' to 'http://fhir.de/StructureDefinition/identifier-standortnummer|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[6]​.pattern​.ofType(Identifier)​.system (l1​/c101907)warningNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer' Type_Specific_Checks_DT_URL_ResolveStructureDefinition
StructureDefinition​.differential​.element[10]​.type[0]​.profile[0] (l1​/c103284)warningThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSStructureDefinition
StructureDefinition​.differential​.element[5]​.slicing​.discriminator[0] (l1​/c101212)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[17]​.slicing​.discriminator[0] (l1​/c65482)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/ISiKStandort could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-mii-pr-icu-muv-zerebraler-perfusionsdruck.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[21]​.slicing​.discriminator[0] (l1​/c71996)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[37]​.slicing​.discriminator[0] (l1​/c93136)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[38]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
StructureDefinition​.snapshot​.element[46]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
StructureDefinition​.snapshot​.element[54]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
ResourceinformationThe resource StructureDefinition/mii-pr-icu-muv-zerebraler-perfusionsdruck could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/mii-pr-icu-muv-zerebraler-perfusionsdruck')warningThe Implementation Guide contains no examples for this profile --

input/resources/StructureDefinition-mii-pr-icu-score-rass.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.differential​.element[5]​.slicing​.discriminator[0] (l1​/c188472)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[18]​.slicing​.discriminator[0] (l1​/c190874)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[21]​.slicing​.discriminator[0] (l1​/c100980)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[44]​.slicing​.discriminator[0] (l1​/c132191)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/mii-pr-icu-score-rass could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenbefund.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.differential​.element[13]​.slicing​.discriminator[0] (l1​/c206948)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[36]​.slicing​.discriminator[0] (l1​/c121029)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/mii-pr-icu-untersuchung-pupillenbefund could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/mii-pr-icu-untersuchung-pupillenbefund')warningThe Implementation Guide contains no examples for this profile --

input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenform.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.differential​.element[18]​.slicing​.discriminator[0] (l1​/c176574)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[54]​.slicing​.discriminator[0] (l1​/c127741)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/mii-pr-icu-untersuchung-pupillenform could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/mii-pr-icu-untersuchung-pupillenform')warningThe Implementation Guide contains no examples for this profile --

input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillengroesse.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.differential​.element[19]​.slicing​.discriminator[0] (l1​/c201667)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[55]​.slicing​.discriminator[0] (l1​/c144117)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot (l1​/c198022)warningThe slice 'valueCodeableConcept' on path 'Observation.value[x]' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true --
StructureDefinition​.snapshot (l1​/c198022)warningThe slice 'valueQuantity' on path 'Observation.value[x]' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true --
ResourceinformationThe resource StructureDefinition/mii-pr-icu-untersuchung-pupillengroesse could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/mii-pr-icu-untersuchung-pupillengroesse')warningThe Implementation Guide contains no examples for this profile --

input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenlichtreaktion-direkt.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.differential​.element[18]​.slicing​.discriminator[0] (l1​/c177210)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[54]​.slicing​.discriminator[0] (l1​/c128340)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/mii-pr-icu-untersuchung-pupillenlichtreaktion-direkt could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenlichtreaktion-indirekt.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.differential​.element[18]​.slicing​.discriminator[0] (l1​/c177222)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[54]​.slicing​.discriminator[0] (l1​/c128350)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/mii-pr-icu-untersuchung-pupillenlichtreaktion-indirekt could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/mii-pr-icu-untersuchung-pupillenlichtreaktion-indirekt')warningThe Implementation Guide contains no examples for this profile --

input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillensymmetrie.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.differential​.element[19]​.slicing​.discriminator[0] (l1​/c199918)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[55]​.slicing​.discriminator[0] (l1​/c138084)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/mii-pr-icu-untersuchung-pupillensymmetrie could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/mii-pr-icu-untersuchung-pupillensymmetrie')warningThe Implementation Guide contains no examples for this profile --

input/resources/StructureDefinition-mii-pr-icu-vent-spontane-atemfrequenz-beatmet.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[74]​.type[0]​.targetProfile[0] (l1​/c133472)warningA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVEStructureDefinition
StructureDefinition​.snapshot​.element[13]​.slicing​.discriminator[0] (l1​/c53429)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[28]​.slicing​.discriminator[0] (l1​/c72334)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[74]​.type[0]​.targetProfile[0]warningUnable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung SD_ED_TYPE_PROFILE_UNKNOWN--
ResourceinformationThe resource StructureDefinition/mii-pr-icu-vent-spontane-atemfrequenz-beatmet could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/mii-pr-icu-vent-spontane-atemfrequenz-beatmet')warningThe Implementation Guide contains no examples for this profile --

input/resources/StructureDefinition-mii-pr-icu-vent-spontanes-atemzugvolumen.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[74]​.type[0]​.targetProfile[0] (l1​/c135250)warningA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVEStructureDefinition
StructureDefinition​.snapshot​.element[13]​.slicing​.discriminator[0] (l1​/c55163)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[28]​.slicing​.discriminator[0] (l1​/c74068)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[74]​.type[0]​.targetProfile[0]warningUnable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung SD_ED_TYPE_PROFILE_UNKNOWN--
ResourceinformationThe resource StructureDefinition/mii-pr-icu-vent-spontanes-atemzugvolumen could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/mii-pr-icu-vent-spontanes-atemzugvolumen')warningThe Implementation Guide contains no examples for this profile --

input/resources/StructureDefinition-mii-pr-icu-vent-unterstuezungsdruck-beatmung.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[74]​.type[0]​.targetProfile[0] (l1​/c131751)warningA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVEStructureDefinition
StructureDefinition​.snapshot​.element[13]​.slicing​.discriminator[0] (l1​/c51678)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[28]​.slicing​.discriminator[0] (l1​/c70583)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[74]​.type[0]​.targetProfile[0]warningUnable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung SD_ED_TYPE_PROFILE_UNKNOWN--
ResourceinformationThe resource StructureDefinition/mii-pr-icu-vent-unterstuezungsdruck-beatmung could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/mii-pr-icu-vent-unterstuezungsdruck-beatmung')warningThe Implementation Guide contains no examples for this profile --

input/resources/StructureDefinition-mii-pr-vent-icu-parameter-von-beatmung.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.differential​.element[32]warningCannot check whether the target profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung on Observation.device is valid constraint on the base because it is not known --
StructureDefinition​.snapshot​.element[74]​.type[0]​.targetProfile[0] (l1​/c186576)warningA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVEStructureDefinition
StructureDefinition​.differential​.element[32]​.type[0]​.targetProfile[0] (l1​/c224765)warningA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVEStructureDefinition
StructureDefinition​.differential​.element[4]​.slicing​.discriminator[0] (l1​/c220444)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[9]​.slicing​.discriminator[0] (l1​/c221147)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[32]​.type[0]​.targetProfile[0]warningUnable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung SD_ED_TYPE_PROFILE_UNKNOWN--
StructureDefinition​.snapshot​.element[13]​.slicing​.discriminator[0] (l1​/c106749)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[28]​.slicing​.discriminator[0] (l1​/c125654)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[74]​.type[0]​.targetProfile[0]warningUnable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung SD_ED_TYPE_PROFILE_UNKNOWN--
ResourceinformationThe resource StructureDefinition/mii-pr-vent-icu-parameter-von-beatmung could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/mii-pr-vent-icu-parameter-von-beatmung')warningThe Implementation Guide contains no examples for this profile --

input/resources/StructureDefinition-sd-mii-icu-intrakranieller-druck-icp.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[21]​.slicing​.discriminator[0] (l1​/c72976)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[37]​.slicing​.discriminator[0] (l1​/c94116)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
ResourceinformationThe resource StructureDefinition/sd-mii-icu-intrakranieller-druck-icp could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/StructureDefinition-sd-mii-icu-monitoring-und-vitaldaten.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.differential​.element[9]​.slicing​.discriminator[0] (l1​/c260472)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[15]​.slicing​.discriminator[0] (l1​/c261705)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[21]​.slicing​.discriminator[0] (l1​/c142441)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[37]​.slicing​.discriminator[0] (l1​/c163581)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[38]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
StructureDefinition​.snapshot​.element[46]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
StructureDefinition​.snapshot​.element[54]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
ResourceinformationThe resource StructureDefinition/sd-mii-icu-monitoring-und-vitaldaten could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
StructureDefinition​.where(url = 'https:​/​/gematik​.de​/fhir​/isik​/StructureDefinition​/sd-mii-icu-monitoring-und-vitaldaten')warningThe Implementation Guide contains no examples for this profile --

input/resources/ValueSet-ISiKBehandlungsergebnisReha.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet (l1/c1668)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present --
ResourcewarningThe resource ValueSet/ISiKBehandlungsergebnisReha should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ISiKBesondereBehandlungsformReha.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet (l1/c1544)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present --
ResourcewarningThe resource ValueSet/ISiKBesondereBehandlungsformReha should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ISiKEncounterClassDE.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[1]informationPinned the version of http://terminology.hl7.org/CodeSystem/v3-ActCode to 10.0.0 from choices of 10.0.0 (hl7.terminology.r4#7.1.0), 7.0.0 (hl7.terminology.r4#5.0.0), 8.0.0 (hl7.fhir.uv.xver-r5.r4#0.1.0), 9.0.0 (hl7.terminology.r4#6.3.0) PIN_VERSION--
ValueSet​.compose​.include[0]​.valueSet[0] (l1​/c2772)warningThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/EncounterClassDE'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/EncounterClassDE' to 'http://fhir.de/ValueSet/EncounterClassDE|1.6.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONSValueSet
ResourcewarningThe resource ValueSet/ISiKEncounterClassDE should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ISiKEncounterTypeErweiterungVS.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0]informationPinned the version of http://fhir.de/CodeSystem/kontaktart-de to 1.6.0 from choices of 1.5.4 (de.basisprofil.r4#1.5.4), 1.6.0 (de.basisprofil.r4#1.6.0) PIN_VERSION--
ResourcewarningThe resource ValueSet/ISiKEncounterTypeErweiterungVS should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ISiKEntlassformReha.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet (l1/c1507)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present --
ResourcewarningThe resource ValueSet/ISiKEntlassformReha should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ISiKLaborMethodeVS.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/ISiKLaborMethodeVS should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ISiKLaborbereichVS.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c2560)informationWrong Display Name 'BLOOD BANK STUDIES' for http://loinc.org#18717-9. Valid display is 'Blutbank-Untersuchungen' (de-DE) (for the language(s) 'de-DE'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[1] (l1​/c2611)informationWrong Display Name 'CELL MARKER STUDIES' for http://loinc.org#18718-7. Valid display is one of 2 choices: 'Cell marker studies (set)' (en-US) or 'Cell marker studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[2] (l1​/c2660)informationWrong Display Name 'CHEMISTRY STUDIES' for http://loinc.org#18719-5. Valid display is one of 2 choices: 'Chemistry studies (set)' (en-US) or 'Chemistry studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[3] (l1​/c2711)informationWrong Display Name 'COAGULATION STUDIES' for http://loinc.org#18720-3. Valid display is one of 2 choices: 'Coagulation studies (set)' (en-US) or 'Coagulation studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[4] (l1​/c2778)informationWrong Display Name 'THERAPEUTIC DRUG MONITORING STUDIES' for http://loinc.org#18721-1. Valid display is one of 2 choices: 'Therapeutic drug monitoring studies (set)' (en-US) or 'Therapeutic drug monitoring studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[5] (l1​/c2827)informationWrong Display Name 'FERTILITY STUDIES' for http://loinc.org#18722-9. Valid display is one of 2 choices: 'Fertility studies (set)' (en-US) or 'Fertility studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[6] (l1​/c2877)informationWrong Display Name 'HEMATOLOGY STUDIES' for http://loinc.org#18723-7. Valid display is one of 2 choices: 'Hematology studies (set)' (en-US) or 'Hematology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[7] (l1​/c2925)informationWrong Display Name 'SEROLOGY STUDIES' for http://loinc.org#18727-8. Valid display is one of 2 choices: 'Serology studies (set)' (en-US) or 'Serology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[8] (l1​/c2975)informationWrong Display Name 'TOXICOLOGY STUDIES' for http://loinc.org#18728-6. Valid display is one of 2 choices: 'Toxicology studies (set)' (en-US) or 'Toxicology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[9] (l1​/c3025)informationWrong Display Name 'URINALYSIS STUDIES' for http://loinc.org#18729-4. Valid display is one of 2 choices: 'Urinalysis studies (set)' (en-US) or 'Urinalysis studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[10] (l1​/c3074)informationWrong Display Name 'BLOOD GAS STUDIES' for http://loinc.org#18767-4. Valid display is one of 2 choices: 'Blood gas studies (set)' (en-US) or 'Blood gas studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[11] (l1​/c3138)informationWrong Display Name 'CELL COUNTS+DIFFERENTIAL STUDIES' for http://loinc.org#18768-2. Valid display is one of 2 choices: 'Cell counts+Differential studies (set)' (en-US) or 'Cell counts+Differential studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[12] (l1​/c3188)informationWrong Display Name 'LABORATORY STUDIES' for http://loinc.org#26436-6. Valid display is one of 2 choices: 'Laboratory studies (set)' (en-US) or 'Laboratory studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[13] (l1​/c3247)informationWrong Display Name 'CHEMISTRY CHALLENGE STUDIES' for http://loinc.org#26437-4. Valid display is one of 2 choices: 'Chemistry challenge studies (set)' (en-US) or 'Chemistry challenge studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/ISiKLaborbereichVS should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ISiKUnterbrechungReha.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet (l1/c1512)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present --
ResourcewarningThe resource ValueSet/ISiKUnterbrechungReha should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ObservationCodesSerumnatrium.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c1338)informationWrong Display Name 'Sodium [Moles/volume] in Serum or Plasma' for http://loinc.org#2951-2. Valid display is 'Natrium [Mol/Volumen] in Serum oder Plasma' (de-DE) or 'Natrium' (de-AT) (for the language(s) 'de-DE'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet (l1/c1343)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present --
ResourcewarningThe resource ValueSet/ObservationCodesSerumnatrium should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ObservationUnitsSerumnatrium.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c1282)informationWrong Display Name 'millimol per liter' for http://unitsofmeasure.org#mmol/L. There are no valid display names found for language(s) 'de-DE'. Default display is 'mmol/L'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet (l1/c1287)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present --
ResourcewarningThe resource ValueSet/ObservationUnitsSerumnatrium should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ProzedurenCodesSCT.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet (l1/c1084)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present --
ResourcewarningThe resource ValueSet/ProzedurenCodesSCT should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ProzedurenKategorieSCT.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c1918)informationThere are no valid display names found for the code http://snomed.info/sct#165197003 for language(s) 'de-DE'. The display is 'Diagnostic assessment' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[3] (l1​/c2070)informationWrong Display Name 'Administration of medicine' for http://snomed.info/sct#18629005. Valid display is one of 9 choices: 'Administration of medication' (en), 'Administration of medication, NOS' (en), 'Giving medication' (en), 'Administration of medication (procedure)' (en), 'Medication administration' (en), 'Medication administration treatments and procedures' (en), 'Medication treatment' (en), 'Administration of drug or medicament (procedure)' (en) or 'Administration of drug or medicament' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet.compose.include[0] (l1/c2234)informationThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Resuscitation (procedure)] and examples for no FSN: [Diagnostic assessment, Imaging, Surgical procedure, Administration of medicine, Therapeutic procedure]) VALUESET_CONCEPT_DISPLAY_SCT_TAG_MIXED--
ValueSet (l1/c2237)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present --
ResourcewarningThe resource ValueSet/ProzedurenKategorieSCT should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-ProzedurenReanimationCodesOPS.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0] (l1/c1927)informationThe concepts in the value set include have not been validated because the code system 'http://fhir.de/CodeSystem/bfarm/ops' is not known, and no terminology service supports it VALUESET_INC_CS_NO_SUPPORT--
ValueSet (l1/c1930)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present --
ResourcewarningThe resource ValueSet/ProzedurenReanimationCodesOPS should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
ValueSet​.where(id = 'ProzedurenReanimationCodesOPS')warningError from https://tx.fhir.org/r4: Error: A definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' could not be found, so the value set cannot be expanded (from server, see log) --

input/resources/ValueSet-ProzedurenReanimationCodesSCT.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet (l1/c1182)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.title is mandatory, but it is not present --
ResourcewarningThe resource ValueSet/ProzedurenReanimationCodesSCT should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-body-site-observation-beatmung.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/mii-vs-icu-body-site-observation-beatmung should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-bodysite-observation-pupillenbefund.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c2071)informationThere are no valid display names found for the code http://snomed.info/sct#16089004 for language(s) 'de-DE'. The display is 'Structure of pupil of left eye' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/mii-vs-icu-bodysite-observation-pupillenbefund should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-category-procedure-beatmung-snomed.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0] (l1/c1993)informationThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Oxygen therapy (procedure)] and examples for no FSN: [Künstliche Beatmung]) VALUESET_CONCEPT_DISPLAY_SCT_TAG_MIXED--
ResourcewarningThe resource ValueSet/mii-vs-icu-category-procedure-beatmung-snomed should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c5267)informationWrong Display Name 'Horowitz index in Arterial blood' for http://loinc.org#50984-4. Valid display is 'Horowitz-Index für arterielles Blut' (de-DE) (for the language(s) 'de-DE'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/mii-vs-icu-code-observation-beatmung-loinc should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc-iso11073.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[3] (l1​/c3443)informationWrong whitespace in Display Name 'Total respiratory rate; total breath rate' for urn:iso:std:iso:11073:10101#152490. Valid display is 'MDC_VENT_RESP_BTSD_PSAZC_RATE' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[4] (l1​/c3500)informationWrong Display Name 'Inspiratory time setting' for urn:iso:std:iso:11073:10101#16929632. Valid display is 'MDC_VENT_TIME_PD_INSP_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[6] (l1​/c3617)informationWrong Display Name 'Tidal volume setting' for urn:iso:std:iso:11073:10101#16929196. Valid display is 'MDC_VENT_VOL_TIDAL_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[9] (l1​/c3815)informationWrong Display Name 'High pressure hold time setting Ventilator' for urn:iso:std:iso:11073:10101#16929860. Valid display is 'MDC_VENT_TIME_PD_INSP_THIGH_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[10] (l1​/c3889)informationWrong Display Name 'Low pressure hold time setting Ventilator' for urn:iso:std:iso:11073:10101#16929864. Valid display is 'MDC_VENT_TIME_PD_EXP_TLOW_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[14] (l1​/c4187)informationWrong Display Name 'Mean pressure Respiratory system airway --on ventilator' for urn:iso:std:iso:11073:10101#151975. Valid display is 'MDC_VENT_PRESS_AWAY_MEAN' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[15] (l1​/c4272)informationWrong Display Name 'Pressure.max Respiratory system airway --on ventilator' for urn:iso:std:iso:11073:10101#151973. Valid display is 'MDC_VENT_PRESS_AWAY_MAX' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/mii-vs-icu-code-observation-beatmung-loinc-iso11073 should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-snomed.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c4268)informationThere are no valid display names found for the code http://snomed.info/sct#250822000 for language(s) 'de-DE'. The display is 'Inspiration/expiration time ratio (observable entity)' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/mii-vs-icu-code-observation-beatmung-snomed should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-code-observation-pupillengroesse.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c1966)informationThere are no valid display names found for the code http://snomed.info/sct#420335002 for language(s) 'de-DE'. The display is 'Medium size pupil' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/mii-vs-icu-code-observation-pupillengroesse should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-code-observation-pupillenlichtreaktion.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c2168)informationThere are no valid display names found for the code http://loinc.org#LA25441-9 for language(s) 'de-DE'. The display is 'Reactive to light' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/mii-vs-icu-code-observation-pupillenlichtreaktion should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-code-observation-pupillensymmetrie.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c1950)informationThere are no valid display names found for the code http://snomed.info/sct#301943000 for language(s) 'de-DE'. The display is 'Pupils equal (finding)' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/mii-vs-icu-code-observation-pupillensymmetrie should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-code-oservation-pupillenform-loinc.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c1990)informationThere are no valid display names found for the code http://loinc.org#LA24884-1 for language(s) 'de-DE'. The display is 'Round' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/mii-vs-icu-code-oservation-pupillenform-loinc should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-code-procedure-beatmung-snomed.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c12732)informationThere are no valid display names found for the code http://snomed.info/sct#1149092001 for language(s) 'de-DE'. The display is 'Positive pressure ventilation' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[12] (l1​/c13654)informationWrong Display Name 'Kontinuierliche positive Atemwegsdruckbeatmung' for http://snomed.info/sct#47545007. Valid display is one of 9 choices: 'Continuous positive airway pressure ventilation treatment' (en), 'CPAP treatment' (en), 'Continuous positive airway pressure ventilation treatment (procedure)' (en), 'CPAP - Continuous positive airways pressure' (en), 'CPAP - Continuous positive airways pressure therapy' (en), 'Continuous positive airways pressure therapy' (en), 'Continuous positive airway pressure ventilation treatment (regime/therapy)' (en), 'CPAP (continuous positive airway pressure) therapy' (en) or 'CPAP (continuous positive airway pressure) treatment' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet.compose.include[0] (l1/c19583)informationThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Respiratory therapy (procedure), Respiratory assist, manual (procedure), Control of end expiratory pressure (procedure), Pulmonary resuscitation (procedure), Positive airway pressure therapy (regime/therapy)] and examples for no FSN: [Positive pressure ventilation, Mechanically assisted spontaneous ventilation, Non-invasive ventilation, Kontinuierliche positive Atemwegsdruckbeatmung, Dual pressure spontaneous ventilation support]) VALUESET_CONCEPT_DISPLAY_SCT_TAG_MIXED--
ResourcewarningThe resource ValueSet/mii-vs-icu-code-procedure-beatmung-snomed should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-mii-vs-icu-score-rass.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c2489)informationThere are no valid display names found for the code http://loinc.org#LA17287-6 for language(s) 'de-DE'. The display is 'Combative' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[1] (l1​/c2539)errorThe code 'LA33959-0' is not valid in the system http://loinc.org (Unknown code 'LA33959-0' in the CodeSystem 'http://loinc.org' version '2.82') VALUESET_INCLUDE_INVALID_CONCEPT_CODE--
ValueSet​.compose​.include[0]​.concept[2] (l1​/c2584)errorThe code 'LA33960-8' is not valid in the system http://loinc.org (Unknown code 'LA33960-8' in the CodeSystem 'http://loinc.org' version '2.82') VALUESET_INCLUDE_INVALID_CONCEPT_CODE--
ValueSet​.compose​.include[0]​.concept[3] (l1​/c2629)informationWrong Display Name 'Restless +1' for http://loinc.org#LA16474-1. Valid display is 'Restless' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[4] (l1​/c2679)errorThe code 'LA33962-4' is not valid in the system http://loinc.org (Unknown code 'LA33962-4' in the CodeSystem 'http://loinc.org' version '2.82') VALUESET_INCLUDE_INVALID_CONCEPT_CODE--
ValueSet​.compose​.include[0]​.concept[5] (l1​/c2722)errorThe code 'LA33963-2' is not valid in the system http://loinc.org (Unknown code 'LA33963-2' in the CodeSystem 'http://loinc.org' version '2.82') VALUESET_INCLUDE_INVALID_CONCEPT_CODE--
ValueSet​.compose​.include[0]​.concept[6] (l1​/c2773)errorThe code 'LA33964-0' is not valid in the system http://loinc.org (Unknown code 'LA33964-0' in the CodeSystem 'http://loinc.org' version '2.82') VALUESET_INCLUDE_INVALID_CONCEPT_CODE--
ValueSet​.compose​.include[0]​.concept[7] (l1​/c2827)errorThe code 'LA33965-7' is not valid in the system http://loinc.org (Unknown code 'LA33965-7' in the CodeSystem 'http://loinc.org' version '2.82') VALUESET_INCLUDE_INVALID_CONCEPT_CODE--
ValueSet​.compose​.include[0]​.concept[8] (l1​/c2877)errorThe code 'LA33966-5' is not valid in the system http://loinc.org (Unknown code 'LA33966-5' in the CodeSystem 'http://loinc.org' version '2.82') VALUESET_INCLUDE_INVALID_CONCEPT_CODE--
ValueSet​.compose​.include[0]​.concept[9] (l1​/c2925)errorThe code 'LA33967-3' is not valid in the system http://loinc.org (Unknown code 'LA33967-3' in the CodeSystem 'http://loinc.org' version '2.82') VALUESET_INCLUDE_INVALID_CONCEPT_CODE--
ResourcewarningThe resource ValueSet/mii-vs-icu-score-rass should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-vs-mii-icu-bodysite-observation-monitoring-und-vitaldaten.json Show Validation Information (1)

PathSeverityMessageValidating
ResourcewarningThe resource ValueSet/vs-mii-icu-bodysite-observation-monitoring-und-vitaldaten should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-iso11073.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[15] (l1​/c5168)informationWrong Display Name 'Oxygen saturation in Arterial blood by Pulse oximetry' for urn:iso:std:iso:11073:10101#150456. Valid display is 'MDC_PULS_OXIM_SAT_O2' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[39] (l1​/c6486)informationWrong Display Name 'Esophageal temperature' for urn:iso:std:iso:11073:10101#150372. Valid display is 'MDC_TEMP_ESOPH' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[40] (l1​/c6540)informationWrong Display Name 'Nasopharynx temperature' for urn:iso:std:iso:11073:10101#150380. Valid display is 'MDC_TEMP_NASOPH' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[42] (l1​/c6657)informationWrong Display Name 'Arterial oxygen saturation' for urn:iso:std:iso:11073:10101#150324. Valid display is 'MDC_SAT_O2_ART' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[43] (l1​/c6711)informationWrong Display Name 'Ideal body weight (IBW)' for urn:iso:std:iso:11073:10101#188796. Valid display is 'MDC_MASS_BODY_EST_IBW' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[44] (l1​/c6762)informationWrong Display Name 'Tympanic temperature' for urn:iso:std:iso:11073:10101#150392. Valid display is 'MDC_TEMP_TYMP' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[45] (l1​/c6811)informationWrong Display Name 'Airway temperature' for urn:iso:std:iso:11073:10101#150356. Valid display is 'MDC_TEMP_AWAY' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-iso11073 should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-loinc.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c7351)informationWrong Display Name 'Heart Rate' for http://loinc.org#8867-4. Valid display is 'Herzfrequenz' (de-DE) or 'Puls' (de-AT) (for the language(s) 'de-DE'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[20] (l1​/c8715)informationWrong Display Name 'Sauerstoffsättigung in arteriellem Blut mittels Pulsoximetrie' for http://loinc.org#59408-5. Valid display is one of 3 choices: 'Oxygen saturation in Arterial blood by Pulse oximetry' (en-US), 'Oxygen saturation in Arterial blood by Pulse oximetry' (en-US) or 'SaO2 % BldA PulseOx' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[36] (l1​/c9844)informationWrong Display Name 'Körpergewicht' for http://loinc.org#29463-7. Valid display is one of 3 choices: 'Body weight' (en-US), 'Body weight' (en-US) or 'Weight' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[38] (l1​/c9935)informationWrong Display Name 'Körpergröße' for http://loinc.org#8302-2. Valid display is one of 3 choices: 'Body height' (en-US), 'Body height' (en-US) or 'Body height' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[40] (l1​/c10056)informationWrong Display Name 'Körpergewicht [Perzentil] pro Alter' for http://loinc.org#8336-0. Valid display is one of 3 choices: 'Body weight [Percentile] Per age' (en-US), 'Body weight [Percentile] Per age' (en-US) or 'Bdy weight Prctl Per Age' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[44] (l1​/c10278)informationWrong Display Name 'Körpertemperatur - Harnblase' for http://loinc.org#8334-5. Valid display is one of 3 choices: 'Body temperature - Urinary bladder' (en-US), 'Body temperature - Urinary bladder' (en-US) or 'Bdy temp Bladder' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[47] (l1​/c10443)informationWrong Display Name 'Körpertemperatur - gemessen im Blut' for http://loinc.org#60834-9. Valid display is one of 3 choices: 'Blood temperature' (en-US), 'Blood temperature' (en-US) or 'Blood temp' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[51] (l1​/c10643)informationWrong Display Name 'Körpertemperatur' for http://loinc.org#8310-5. Valid display is one of 3 choices: 'Body temperature' (en-US), 'Body temperature' (en-US) or 'Body temperature' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-loinc should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[15] (l1​/c6504)informationWrong Display Name 'Körpergewicht' for http://snomed.info/sct#27113001. Valid display is one of 3 choices: 'Body weight' (en), 'Body weight, NOS' (en) or 'Body weight (observable entity)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[17] (l1​/c6601)informationWrong Display Name 'Körpergröße' for http://snomed.info/sct#1153637007. Valid display is one of 2 choices: 'Body height (observable entity)' (en) or 'Body height' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[20] (l1​/c6804)informationWrong Display Name 'Körperkerntemperatur gemessen am Trommelfell' for http://snomed.info/sct#415974002. Valid display is one of 5 choices: 'Tympanic temperature (observable entity)' (en), 'Tympanic temperature' (en), 'Aural temperature' (en), 'Core body temperature measured at tympanic membrane (observable entity)' (en) or 'Core body temperature measured at tympanic membrane' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[21] (l1​/c6854)informationWrong Display Name 'Rektaltemperatur' for http://snomed.info/sct#307047009. Valid display is one of 4 choices: 'Rectal temperature' (en), 'Rectal temperature (observable entity)' (en), 'Core body temperature measured in rectum (observable entity)' (en) or 'Core body temperature measured in rectum' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[22] (l1​/c6930)informationWrong Display Name 'Körperkerntemperatur gemessen im Ösophagus' for http://snomed.info/sct#431598003. Valid display is one of 6 choices: 'Temperature of esophagus (observable entity)' (en), 'Temperature of esophagus' (en), 'Temperature of oesophagus' (en), 'Core body temperature measured in esophagus (observable entity)' (en), 'Core body temperature measured in esophagus' (en) or 'Core body temperature measured in oesophagus' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[23] (l1​/c7008)informationWrong Display Name 'Körperkerntemperatur gemessen im Nasopharynx' for http://snomed.info/sct#698831002. Valid display is one of 4 choices: 'Nasopharyngeal temperature' (en), 'Nasopharyngeal temperature (observable entity)' (en), 'Core body temperature measured in nasopharynx (observable entity)' (en) or 'Core body temperature measured in nasopharynx' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[24] (l1​/c7088)informationWrong Display Name 'Körperkerntemperatur gemessen an der Harnblase' for http://snomed.info/sct#698832009. Valid display is one of 8 choices: 'Bladder temperature (observable entity)' (en), 'Bladder temperature' (en), 'Intravesical temperature' (en), 'Temperature of bladder' (en), 'Temperature of urinary bladder' (en), 'Core body temperature measured at urinary bladder (observable entity)' (en), 'Core body temperature measured at urinary bladder' (en) or 'Urinary bladder temperature' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[25] (l1​/c7139)informationWrong Display Name 'Vaginaltemperatur' for http://snomed.info/sct#364246006. Valid display is one of 4 choices: 'Temperature of vagina' (en), 'Temperature of vagina (observable entity)' (en), 'Core body temperature measured vaginally (observable entity)' (en) or 'Core body temperature measured vaginally' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[27] (l1​/c7243)informationWrong Display Name 'Orale Temperatur' for http://snomed.info/sct#415945006. Valid display is one of 6 choices: 'Oral temperature (observable entity)' (en), 'Oral temperature' (en), 'Core body temperature measured in sublingual space (observable entity)' (en), 'Core body temperature measured in sublingual space' (en), 'Estimated core body temperature measured in sublingual space (observable entity)' (en) or 'Estimated core body temperature measured in sublingual space' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[29] (l1​/c7366)informationWrong Display Name 'Körperkerntemperatur im Blut gemessen' for http://snomed.info/sct#1222808002. Valid display is one of 3 choices: 'Temperature of blood' (en), 'Core body temperature measured in blood (observable entity)' (en) or 'Core body temperature measured in blood' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[32] (l1​/c7527)informationWrong Display Name 'Stirntemperatur' for http://snomed.info/sct#415922000. Valid display is one of 4 choices: 'Forehead temperature (observable entity)' (en), 'Forehead temperature' (en), 'Temperature of forehead (observable entity)' (en) or 'Temperature of forehead' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ResourcewarningThe resource ValueSet/vs-mii-icu-code-monitoring-und-vitaldaten-snomed should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

temp/pages/_includes/artifacts.xml Show Validation Information (0)


template/config Show Validation Information (0)


template/config/_config.yml Show Validation Information (0)

Suppressed Messages (Warnings, hints, broken links)

Error from https://tx.fhir.de/fhir: Error: Invalid request

It's OK that references to examples of other modules cannot be resolved

That's an error that we are unable to resolve

The IHE package does not have an IG

There are missing dependencies in the IG-Publisher validation, but there is no error during manual validation

Errors sorted by type


All_observations_should_have_a_performer

input/resources/Observation-ExampleOrganPupilLightReactionLeft20200311.jsonBest Practice Recommendation: In general, all observations should have a performer--
input/resources/Observation-ExampleOrganPupilLightReactionLeftPrompt20200311.jsonBest Practice Recommendation: In general, all observations should have a performer--
input/resources/Observation-ExampleOrganPupilLightReactionLeftVerzogert20200311.jsonBest Practice Recommendation: In general, all observations should have a performer--
input/resources/Observation-ExampleOrganPupilLightReactionRight20200311.jsonBest Practice Recommendation: In general, all observations should have a performer--
input/resources/Observation-ExampleOrganPupilLightReactionRightKeine20200311.jsonBest Practice Recommendation: In general, all observations should have a performer--
input/resources/Observation-ExampleOrganRASS20200311.jsonBest Practice Recommendation: In general, all observations should have a performer--
input/resources/Observation-ISiKGCSMinExample.jsonBest Practice Recommendation: In general, all observations should have a performer--
input/resources/Observation-Intrakranieller-Druck-ICP.jsonBest Practice Recommendation: In general, all observations should have a performer--

CODESYSTEM_SHAREABLE_MISSING

input/resources/CodeSystem-ISiKBehandlungsergebnisRehaCS.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present--
input/resources/CodeSystem-ISiKBesondereBehandlungsformRehaCS.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present--
input/resources/CodeSystem-ISiKEntlassformRehaCS.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present--
input/resources/CodeSystem-ISiKUnterbrechungRehaCS.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.title is mandatory, but it is not present--

Details_for__matching_against_Profile_

input/resources/Encounter-FachabteilungskontaktBettenverlegung.jsonThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktFachbereichswechsel1.jsonThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-isik-encounter-Sternenfall.jsonThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKKontaktGesundheitseinrichtung|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKKontaktGesundheitseinrichtung
input/resources/Patient-IsikPatientTemplate.jsonThis element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/humanname-de-basis|1.6.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKPatient
input/resources/Patient-IsikPatientTemplate.jsonThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKPatient
input/resources/Patient-IsikPatientTemplate.jsonThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKPatient
input/resources/Patient-IsikPatientTemplate.jsonThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKPatient
input/resources/Patient-IsikPatientTemplate.jsonThis element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.6.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKPatient
input/resources/Patient-IsikPatientTemplate.jsonThis element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.6.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKPatient
input/resources/Patient-IsikPatientTemplate.jsonThis element does not match any known slice defined in the profile http://fhir.de/StructureDefinition/address-de-basis|1.6.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKPatient
input/resources/Patient-IsikPatientTemplate.jsonThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKPatient
input/resources/Patient-IsikPatientTemplate.jsonThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKPatient
input/resources/Patient-IsikPatientTemplate.jsonThis element does not match any known slice defined in the profile https://gematik.de/fhir/isik/StructureDefinition/ISiKPatient|6.0.0 (this may not be a problem, but you should check that it's not intended to match a slice)ISiKPatient

Display_Name_for__should_be_one_of__instead_of

input/resources/Procedure-Appendektomie.jsonWrong Display Name 'Chirurgische Prozedur' for http://snomed.info/sct#387713003. Valid display is 'Surgical procedure' (for the language(s) 'de-DE')ISiKProzedur

FHIRPATH_COLLECTION_STATUS_OPERATION_LEFT

input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonISiK-enc-8: The left side is inherently a collection, and so the expression 'coding.code != 'billing'' may fail or return false if there is more than one item in the content being evaluated--

IG_DEPENDENCY_DIRECT

fsh-generated/resources/ImplementationGuide-organspendeerkennung.jsonThe URL should refer directly to the ImplementationGuide resource (e.g. include '/ImplementationGuide/')--

IG_DEPENDENCY_INVALID_URL

fsh-generated/resources/ImplementationGuide-organspendeerkennung.jsonThe canonical URL http://fhir.org/packages/de.basisprofil.r4/ImplementationGuide/de.basisprofil.r4 doesn't point to an actual ImplementationGuide resource--
fsh-generated/resources/ImplementationGuide-organspendeerkennung.jsonThe canonical URL http://fhir.de/packages/de.ihe-d.terminology doesn't point to an actual ImplementationGuide resource--

IG_DEPENDENCY_VERSION_WARNING

fsh-generated/resources/ImplementationGuide-organspendeerkennung.jsonThe ImplementationGuide is based on FHIR version 4.0.1 but package hl7.fhir.uv.subscriptions-backport.r4#1.1.0 is based on FHIR version 4.0.0. In general, this version mismatch should be avoided - some tools will try to make this work with variable degrees of success, but others will not even try--

IG_DEPENDENCY_VERSION_WARNING_OLD

fsh-generated/resources/ImplementationGuide-organspendeerkennung.jsonThe ImplementationGuide uses package hl7.fhir.uv.ips#2.0.0 released on 2025-10-03, but the most recent appropriate version is 2.0.1. This reference is getting old and the more recent version should be considered--
fsh-generated/resources/ImplementationGuide-organspendeerkennung.jsonThe ImplementationGuide uses package ihe.formatcode.fhir#1.4.0 released on 2025-05-20, but the most recent appropriate version is 1.5.0. This reference is getting old and the more recent version should be considered--

INACTIVE_CONCEPT_FOUND

input/resources/Patient-PatientinMusterfrau.jsonThe concept 'PKV' has a status of inactive and its use should be reviewedISiKPatient
input/resources/Patient-PatientinMusterfrau.jsonThe concept 'PKV' has a status of retired and its use should be reviewedISiKPatient
input/resources/StructureDefinition-ISiKPatient.jsonThe concept 'PKV' has a status of inactive and its use should be reviewedStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe concept 'PKV' has a status of retired and its use should be reviewedStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe concept 'PKV' has a status of inactive and its use should be reviewedStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe concept 'PKV' has a status of retired and its use should be reviewedStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe concept 'PKV' has a status of inactive and its use should be reviewedStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe concept 'PKV' has a status of retired and its use should be reviewedStructureDefinition

MSG_DEPENDS_ON_DEPRECATED_NOTE

input/resources/StructureDefinition-ISiKGCS.jsonThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe extension http://hl7.org/fhir/StructureDefinition/regex|5.3.0 is deprecated with the note: 'This was deprecated in favor of using a constraint on the element using FHIRPath, since constraints allow for the provision of a human readable message associated with the regex'StructureDefinition

MSG_DRAFT

input/resources/Encounter-Fachabteilungskontakt.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktBettenverlegung.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktEntlassung.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktFachbereichswechsel1.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktFachbereichswechsel2.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktMinimal2.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationaereAufnahme.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationswechsel1.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationswechsel2.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Nachstationaer.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Stationaer.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Vorstationaer.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ2Encounter.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-isik-encounter-Sternenfall.jsonReference to draft CodeSystem http://hl7.org/fhir/encounter-status|4.0.1ISiKKontaktGesundheitseinrichtung

NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_ERR

input/resources/Encounter-isik-encounter-Sternenfall.jsonWrong Display Name 'Inpatient' for http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP. There are no valid display names found for language(s) 'de-DE'. Default display is 'inpatient encounter'ISiKKontaktGesundheitseinrichtung
input/resources/Observation-ExampleISiKLaboruntersuchungMaximal.jsonWrong Display Name 'Positiv' for http://snomed.info/sct#10828004. There are no valid display names found for language(s) 'de-DE'. Default display is 'Positive'ISiKLaboruntersuchung
input/resources/Observation-ExampleISiKLaboruntersuchungMaximal.jsonWrong Display Name 'Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique' for http://snomed.info/sct#83581000052107. There are no valid display names found for language(s) 'de-DE'. Default display is 'Matrix assisted laser desorption ionization time of flight mass spectrometry technique'ISiKLaboruntersuchung
input/resources/Observation-ExampleISiKLaboruntersuchungSerumnatrium1.jsonWrong Display Name 'Weiblich' for http://snomed.info/sct#248152002. There are no valid display names found for language(s) 'de-DE'. Default display is 'Female'ISiKLaboruntersuchungSerumnatrium
input/resources/Observation-ISiKGCSMaxExample.jsonWrong Display Name 'Eye opening spontaneously' for http://loinc.org#LA6556-0. There are no valid display names found for language(s) 'de-DE'. Default display is 'Eyes open spontaneously'ISiKGCS
input/resources/Procedure-Appendektomie.jsonWrong Display Name 'Chirurgische Prozedur' for http://snomed.info/sct#387713003. There are no valid display names found for language(s) 'de-DE'. Default display is 'Surgical procedure'ISiKProzedur
input/resources/Procedure-Appendektomie.jsonWrong Display Name 'Appendektomie' for http://snomed.info/sct#80146002. There are no valid display names found for language(s) 'de-DE'. Default display is 'Appendectomy'ISiKProzedur
input/resources/StructureDefinition-ISiKPatient.jsonWrong Display Name 'Deutschland' for urn:iso:std:iso:3166#DE. There are no valid display names found for language(s) 'de-DE'. Default display is 'Germany'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonWrong Display Name 'Deutschland' for urn:iso:std:iso:3166#DE. There are no valid display names found for language(s) 'de-DE'. Default display is 'Germany'StructureDefinition

NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK

input/resources/Location-KrankenhausStandortBeispiel.jsonThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-RoleCode#HOSP for language(s) 'de-DE'. The display is 'Hospital' which is a valid display for the default languageISiKStandort
input/resources/Location-StationICUStandortBeispiel.jsonThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-RoleCode#ICU for language(s) 'de-DE'. The display is 'Intensive care unit' which is a valid display for the default languageISiKStandort
input/resources/Location-StationPediaICUStandortBeispiel.jsonThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-RoleCode#PEDICU for language(s) 'de-DE'. The display is 'Pediatric intensive care unit' which is a valid display for the default languageISiKStandort
input/resources/Location-StationStandortBeispiel.jsonThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-RoleCode#HU for language(s) 'de-DE'. The display is 'Hospital unit' which is a valid display for the default languageISiKStandort
input/resources/Location-isik-station-anaesthesie.jsonThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-RoleCode#ICU for language(s) 'de-DE'. The display is 'Intensive care unit' which is a valid display for the default languageISiKStandort
input/resources/Observation-ExampleOrganPupilLightReactionLeft20200311.jsonThere are no valid display names found for the code http://snomed.info/sct#45832002 for language(s) 'de-DE'. The display is 'Pupil afferent light reaction' which is a valid display for the default languageMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
input/resources/Observation-ExampleOrganPupilLightReactionLeftPrompt20200311.jsonThere are no valid display names found for the code http://snomed.info/sct#45832002 for language(s) 'de-DE'. The display is 'Pupil afferent light reaction' which is a valid display for the default languageMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
input/resources/Observation-ExampleOrganPupilLightReactionLeftPrompt20200311.jsonThere are no valid display names found for the code http://loinc.org#LA25441-9 for language(s) 'de-DE'. The display is 'Reactive to light' which is a valid display for the default languageMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
input/resources/Observation-ExampleOrganPupilLightReactionLeftVerzogert20200311.jsonThere are no valid display names found for the code http://snomed.info/sct#45832002 for language(s) 'de-DE'. The display is 'Pupil afferent light reaction' which is a valid display for the default languageMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
input/resources/Observation-ExampleOrganPupilLightReactionLeftVerzogert20200311.jsonThere are no valid display names found for the code http://loinc.org#LA24899-9 for language(s) 'de-DE'. The display is 'Sluggishly reactive to light' which is a valid display for the default languageMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
input/resources/Observation-ExampleOrganPupilLightReactionRight20200311.jsonThere are no valid display names found for the code http://snomed.info/sct#45832002 for language(s) 'de-DE'. The display is 'Pupil afferent light reaction' which is a valid display for the default languageMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
input/resources/Observation-ExampleOrganPupilLightReactionRightKeine20200311.jsonThere are no valid display names found for the code http://snomed.info/sct#45832002 for language(s) 'de-DE'. The display is 'Pupil afferent light reaction' which is a valid display for the default languageMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
input/resources/Observation-ExampleOrganPupilLightReactionRightKeine20200311.jsonThere are no valid display names found for the code http://loinc.org#LA25442-7 for language(s) 'de-DE'. The display is 'Not reactive to light' which is a valid display for the default languageMII PR ICU Untersuchung Pupillenlichtreaktion Direkt
input/resources/Observation-ExampleOrganRASS20200311.jsonThere are no valid display names found for the code http://snomed.info/sct#1345050000 for language(s) 'de-DE'. The display is 'Richmond Agitation Sedation Scale score' which is a valid display for the default languageMII PR ICU Score RASS
input/resources/Observation-ISiKGCSExample.jsonThere are no valid display names found for the code http://loinc.org#9269-2 for language(s) 'de-DE'. The display is 'Glasgow coma score total' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSExample.jsonThere are no valid display names found for the code http://loinc.org#9270-0 for language(s) 'de-DE'. The display is 'Glasgow coma score verbal' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSExample.jsonThere are no valid display names found for the code http://loinc.org#LA6560-2 for language(s) 'de-DE'. The display is 'Confused' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSExample.jsonThere are no valid display names found for the code http://loinc.org#9268-4 for language(s) 'de-DE'. The display is 'Glasgow coma score motor' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSExample.jsonThere are no valid display names found for the code http://loinc.org#LA6566-9 for language(s) 'de-DE'. The display is 'Localizing pain' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSExample.jsonThere are no valid display names found for the code http://loinc.org#9267-6 for language(s) 'de-DE'. The display is 'Glasgow coma score eye opening' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSExample.jsonThere are no valid display names found for the code http://loinc.org#LA6555-2 for language(s) 'de-DE'. The display is 'Eye opening to verbal command' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMaxExample.jsonThere are no valid display names found for the code http://loinc.org#9269-2 for language(s) 'de-DE'. The display is 'Glasgow coma score total' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMaxExample.jsonThere are no valid display names found for the code http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation#N for language(s) 'de-DE'. The display is 'Normal' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMaxExample.jsonThere are no valid display names found for the code http://loinc.org#9270-0 for language(s) 'de-DE'. The display is 'Glasgow coma score verbal' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMaxExample.jsonThere are no valid display names found for the code http://loinc.org#LA6558-6 for language(s) 'de-DE'. The display is 'Incomprehensible sounds' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMaxExample.jsonThere are no valid display names found for the code http://loinc.org#9268-4 for language(s) 'de-DE'. The display is 'Glasgow coma score motor' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMaxExample.jsonThere are no valid display names found for the code http://loinc.org#LA6567-7 for language(s) 'de-DE'. The display is 'Obeys commands' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMaxExample.jsonThere are no valid display names found for the code http://loinc.org#9267-6 for language(s) 'de-DE'. The display is 'Glasgow coma score eye opening' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMinExample.jsonThere are no valid display names found for the code http://loinc.org#9269-2 for language(s) 'de-DE'. The display is 'Glasgow coma score total' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMinExample.jsonThere are no valid display names found for the code http://loinc.org#9270-0 for language(s) 'de-DE'. The display is 'Glasgow coma score verbal' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMinExample.jsonThere are no valid display names found for the code http://loinc.org#LA6557-8 for language(s) 'de-DE'. The display is 'No verbal response (>2 yrs); no vocal response (<=2 yrs)' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMinExample.jsonThere are no valid display names found for the code http://loinc.org#9268-4 for language(s) 'de-DE'. The display is 'Glasgow coma score motor' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMinExample.jsonThere are no valid display names found for the code http://loinc.org#LA6562-8 for language(s) 'de-DE'. The display is 'No motor response' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMinExample.jsonThere are no valid display names found for the code http://loinc.org#9267-6 for language(s) 'de-DE'. The display is 'Glasgow coma score eye opening' which is a valid display for the default languageISiKGCS
input/resources/Observation-ISiKGCSMinExample.jsonThere are no valid display names found for the code http://loinc.org#LA6553-7 for language(s) 'de-DE'. The display is 'No eye opening' which is a valid display for the default languageISiKGCS
input/resources/Observation-Intrakranieller-Druck-ICP.jsonThere are no valid display names found for the code http://snomed.info/sct#250844005 for language(s) 'de-DE'. The display is 'Intracranial pressure' which is a valid display for the default languageSD MII ICU Intrakranieller Druck ICP
input/resources/Procedure-ExampleOrganVentilationMode20200311.jsonThere are no valid display names found for the code http://snomed.info/sct#243142003 for language(s) 'de-DE'. The display is 'Dual pressure spontaneous ventilation support' which is a valid display for the default languageISiK Prozedur Beatmung
input/resources/Procedure-ExampleOrganVentilationModeASV.jsonThere are no valid display names found for the code http://snomed.info/sct#1186620002 for language(s) 'de-DE'. The display is 'Minimum minute volume ventilation' which is a valid display for the default languageISiK Prozedur Beatmung
input/resources/Procedure-ExampleOrganVentilationModeBiLev.jsonThere are no valid display names found for the code http://snomed.info/sct#1186618000 for language(s) 'de-DE'. The display is 'Bilevel artificial ventilation' which is a valid display for the default languageISiK Prozedur Beatmung
input/resources/Procedure-ExampleOrganVentilationModeNIV.jsonThere are no valid display names found for the code http://snomed.info/sct#428311008 for language(s) 'de-DE'. The display is 'Non-invasive ventilation' which is a valid display for the default languageISiK Prozedur Beatmung
input/resources/Procedure-ExampleOrganVentilationModePCMod.jsonThere are no valid display names found for the code http://snomed.info/sct#1149092001 for language(s) 'de-DE'. The display is 'Positive pressure ventilation' which is a valid display for the default languageISiK Prozedur Beatmung
input/resources/Procedure-ExampleOrganVentilationModePSIMV.jsonThere are no valid display names found for the code http://snomed.info/sct#1186622005 for language(s) 'de-DE'. The display is 'Synchronized intermittent mandatory ventilation - pressure-control pressure-support inflation' which is a valid display for the default languageISiK Prozedur Beatmung
input/resources/Procedure-ExampleOrganVentilationModeSPNMod.jsonThere are no valid display names found for the code http://snomed.info/sct#243141005 for language(s) 'de-DE'. The display is 'Mechanically assisted spontaneous ventilation' which is a valid display for the default languageISiK Prozedur Beatmung
input/resources/Procedure-ExampleOrganVentilationModeStMod.jsonThere are no valid display names found for the code http://snomed.info/sct#1186618000 for language(s) 'de-DE'. The display is 'Bilevel artificial ventilation' which is a valid display for the default languageISiK Prozedur Beatmung
input/resources/Procedure-ExampleOrganVentilationModenC.jsonThere are no valid display names found for the code http://snomed.info/sct#229312009 for language(s) 'de-DE'. The display is 'Nasal ventilation therapy' which is a valid display for the default languageISiK Prozedur Beatmung
input/resources/Procedure-ReanimationBeispiel.jsonThere are no valid display names found for the code http://snomed.info/sct#439569004 for language(s) 'de-DE'. The display is 'Resuscitation (procedure)' which is a valid display for the default languageISiK Prozedur Reanimation
input/resources/StructureDefinition-ISiKProzedurReanimation.jsonThere are no valid display names found for the code http://snomed.info/sct#439569004 for language(s) 'de-DE'. The display is 'Resuscitation (procedure)' which is a valid display for the default languageStructureDefinition
input/resources/StructureDefinition-ISiKProzedurReanimation.jsonThere are no valid display names found for the code http://snomed.info/sct#439569004 for language(s) 'de-DE'. The display is 'Resuscitation (procedure)' which is a valid display for the default languageStructureDefinition

PIN_VERSION

input/resources/ValueSet-ISiKEncounterClassDE.jsonPinned the version of http://terminology.hl7.org/CodeSystem/v3-ActCode to 10.0.0 from choices of 10.0.0 (hl7.terminology.r4#7.1.0), 7.0.0 (hl7.terminology.r4#5.0.0), 8.0.0 (hl7.fhir.uv.xver-r5.r4#0.1.0), 9.0.0 (hl7.terminology.r4#6.3.0)--
input/resources/ValueSet-ISiKEncounterTypeErweiterungVS.jsonPinned the version of http://fhir.de/CodeSystem/kontaktart-de to 1.6.0 from choices of 1.5.4 (de.basisprofil.r4#1.5.4), 1.6.0 (de.basisprofil.r4#1.6.0)--

Reference_REF_CantResolve

input/resources/Encounter-Fachabteilungskontakt.jsonUnable to resolve resource with reference 'Condition/BehandlungsDiagnoseFreitext'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-Fachabteilungskontakt.jsonUnable to resolve resource with reference 'Account/AbrechnungsfallDRG'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonUnable to resolve resource with reference 'Condition/PrimaereGonarthroseNormal'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonUnable to resolve resource with reference 'Account/AbrechnungsfallGonarthrose'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonUnable to resolve resource with reference 'Location/RaumStandortBeispiel'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonUnable to resolve resource with reference 'Location/BettenstellplatzStandortBeispiel'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Nachstationaer.jsonUnable to resolve resource with reference 'Account/SZ1DRGFall'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Stationaer.jsonUnable to resolve resource with reference 'Account/SZ1DRGFall'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Vorstationaer.jsonUnable to resolve resource with reference 'Account/SZ1DRGFall'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ2Encounter.jsonUnable to resolve resource with reference 'Account/SZ2DRGFall'ISiKKontaktGesundheitseinrichtung
input/resources/Location-KrankenhausStandortBeispiel.jsonUnable to resolve resource with reference 'Organization/KrankenhausOrganisationBeispiel'ISiKStandort
input/resources/Location-StationICUStandortBeispiel.jsonUnable to resolve resource with reference 'Organization/KlinikIntensivAnaesthesieOrganisationBeispiel'ISiKStandort
input/resources/Location-StationPediaICUStandortBeispiel.jsonUnable to resolve resource with reference 'Organization/KlinikPaediatrieOrganisationBeispiel'ISiKStandort
input/resources/Location-StationStandortBeispiel.jsonUnable to resolve resource with reference 'Organization/AbteilungAllgemeinchirurgieOrganisationBeispiel'ISiKStandort
input/resources/Location-isik-station-anaesthesie.jsonUnable to resolve resource with reference 'Organization/KrankenhausOrganisationBeispiel'ISiKStandort
input/resources/Observation-ExampleISiKLaboruntersuchungMaximal.jsonUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt'ISiKLaboruntersuchung
input/resources/Observation-ExampleISiKLaboruntersuchungSerumnatrium1.jsonUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt'ISiKLaboruntersuchungSerumnatrium
input/resources/Observation-ExampleOrganSerumNatrium202003110104.jsonUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt'ISiKLaboruntersuchungSerumnatrium
input/resources/Observation-ExampleOrganSerumNatrium202003110159.jsonUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt'ISiKLaboruntersuchungSerumnatrium
input/resources/Observation-ExampleOrganSerumNatrium202003110306.jsonUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt'ISiKLaboruntersuchungSerumnatrium
input/resources/Observation-ISiKGCSExample.jsonUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt'ISiKGCS
input/resources/Observation-ISiKGCSMaxExample.jsonUnable to resolve resource with reference 'Practitioner/PractitionerWalterArzt'ISiKGCS

SD_ED_TYPE_PROFILE_UNKNOWN

input/resources/StructureDefinition-mii-pr-icu-vent-spontane-atemfrequenz-beatmet.jsonUnable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung--
input/resources/StructureDefinition-mii-pr-icu-vent-spontanes-atemzugvolumen.jsonUnable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung--
input/resources/StructureDefinition-mii-pr-icu-vent-unterstuezungsdruck-beatmung.jsonUnable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung--
input/resources/StructureDefinition-mii-pr-vent-icu-parameter-von-beatmung.jsonUnable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung--
input/resources/StructureDefinition-mii-pr-vent-icu-parameter-von-beatmung.jsonUnable to resolve profile https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung--

SD_PATH_SLICING_DEPRECATED

input/resources/StructureDefinition-ISiKGCS.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKGCS.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKGCS.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKLaboruntersuchung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKLaboruntersuchung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKLaboruntersuchung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKLaboruntersuchung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKLaboruntersuchung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKLaboruntersuchung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKLaboruntersuchungSerumnatrium.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKLaboruntersuchungSerumnatrium.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKLaboruntersuchungSerumnatrium.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKPatient.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKPatient.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKPatient.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKPatient.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKPatient.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKPatient.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKProzedur.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKProzedur.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKProzedur.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKProzedur.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKProzedurBeatmung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKProzedurBeatmung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKProzedurReanimation.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKProzedurReanimation.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKStandort.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-ISiKStandort.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-muv-zerebraler-perfusionsdruck.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-muv-zerebraler-perfusionsdruck.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-score-rass.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-score-rass.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-score-rass.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-score-rass.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenbefund.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenbefund.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenform.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenform.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillengroesse.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillengroesse.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenlichtreaktion-direkt.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenlichtreaktion-direkt.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenlichtreaktion-indirekt.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillenlichtreaktion-indirekt.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillensymmetrie.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-untersuchung-pupillensymmetrie.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-vent-spontane-atemfrequenz-beatmet.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-vent-spontane-atemfrequenz-beatmet.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-vent-spontanes-atemzugvolumen.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-vent-spontanes-atemzugvolumen.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-vent-unterstuezungsdruck-beatmung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-icu-vent-unterstuezungsdruck-beatmung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-vent-icu-parameter-von-beatmung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-vent-icu-parameter-von-beatmung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-vent-icu-parameter-von-beatmung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-mii-pr-vent-icu-parameter-von-beatmung.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-sd-mii-icu-intrakranieller-druck-icp.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-sd-mii-icu-intrakranieller-druck-icp.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-sd-mii-icu-monitoring-und-vitaldaten.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-sd-mii-icu-monitoring-und-vitaldaten.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-sd-mii-icu-monitoring-und-vitaldaten.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
input/resources/StructureDefinition-sd-mii-icu-monitoring-und-vitaldaten.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--

SD_VALUE_TYPE_REPEAT_HINT

input/resources/StructureDefinition-ISiKGCS.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--
input/resources/StructureDefinition-ISiKLaboruntersuchung.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--
input/resources/StructureDefinition-ISiKLaboruntersuchungSerumnatrium.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--
input/resources/StructureDefinition-ISiKPatient.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--
input/resources/StructureDefinition-ISiKPatient.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--
input/resources/StructureDefinition-ISiKPatient.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--
input/resources/StructureDefinition-mii-pr-icu-muv-zerebraler-perfusionsdruck.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--
input/resources/StructureDefinition-mii-pr-icu-muv-zerebraler-perfusionsdruck.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--
input/resources/StructureDefinition-mii-pr-icu-muv-zerebraler-perfusionsdruck.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--
input/resources/StructureDefinition-sd-mii-icu-monitoring-und-vitaldaten.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--
input/resources/StructureDefinition-sd-mii-icu-monitoring-und-vitaldaten.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--
input/resources/StructureDefinition-sd-mii-icu-monitoring-und-vitaldaten.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--

SECURITY_STRING_CONTENT_WARNING

input/resources/StructureDefinition-ISiKPatient.jsonThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security riskStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security riskStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security riskStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security riskStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security riskStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security riskStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security riskStructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThe string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security riskStructureDefinition

TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS

input/resources/StructureDefinition-ExtensionISiKCapabilityStatementImportsExpectation.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/conformance-expectation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '2.0.0', found versions: 0.3.0 (from hl7.terminology.r4#5.0.0), 1.0.0 (from hl7.terminology.r4#6.5.0), 2.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/conformance-expectation' to 'http://terminology.hl7.org/ValueSet/conformance-expectation|2.0.0'StructureDefinition
input/resources/StructureDefinition-ExtensionISiKCapabilityStatementImportsExpectation.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/conformance-expectation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '2.0.0', found versions: 0.3.0 (from hl7.terminology.r4#5.0.0), 1.0.0 (from hl7.terminology.r4#6.5.0), 2.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/conformance-expectation' to 'http://terminology.hl7.org/ValueSet/conformance-expectation|2.0.0'StructureDefinition
input/resources/StructureDefinition-ISiKGCS.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/observation-de-score-gcs'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/observation-de-score-gcs' to 'http://fhir.de/StructureDefinition/observation-de-score-gcs|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKGCS.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/observation-de-score-gcs'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/observation-de-score-gcs' to 'http://fhir.de/StructureDefinition/observation-de-score-gcs|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKGCS.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/glasgow-coma-score-eye'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/glasgow-coma-score-eye' to 'http://fhir.de/ValueSet/glasgow-coma-score-eye|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKGCS.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/glasgow-coma-score-motor'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/glasgow-coma-score-motor' to 'http://fhir.de/ValueSet/glasgow-coma-score-motor|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKGCS.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/glasgow-coma-score-verbal'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/glasgow-coma-score-verbal' to 'http://fhir.de/ValueSet/glasgow-coma-score-verbal|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Aufnahmegrund'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Aufnahmegrund' to 'http://fhir.de/StructureDefinition/Aufnahmegrund|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/AufnahmegrundErsteUndZweiteStelle'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/AufnahmegrundErsteUndZweiteStelle' to 'http://fhir.de/ValueSet/dkgev/AufnahmegrundErsteUndZweiteStelle|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/AufnahmegrundDritteStelle'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/AufnahmegrundDritteStelle' to 'http://fhir.de/ValueSet/dkgev/AufnahmegrundDritteStelle|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/AufnahmegrundVierteStelle'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/AufnahmegrundVierteStelle' to 'http://fhir.de/ValueSet/dkgev/AufnahmegrundVierteStelle|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/EncounterStatusDe'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/EncounterStatusDe' to 'http://fhir.de/ValueSet/EncounterStatusDe|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode' to 'http://terminology.hl7.org/ValueSet/v3-ActEncounterCode|3.0.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/kontaktebene-de'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/kontaktebene-de' to 'http://fhir.de/ValueSet/kontaktebene-de|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel' to 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert' to 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActPriority'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActPriority' to 'http://terminology.hl7.org/ValueSet/v3-ActPriority|3.0.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/DiagnoseTyp'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/DiagnoseTyp' to 'http://fhir.de/ValueSet/DiagnoseTyp|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/Diagnosesubtyp'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/Diagnosesubtyp' to 'http://fhir.de/ValueSet/Diagnosesubtyp|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Wahlleistung'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Wahlleistung' to 'http://fhir.de/StructureDefinition/Wahlleistung|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass' to 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0092'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#6.5.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0092' to 'http://terminology.hl7.org/ValueSet/v2-0092|3.0.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Entlassungsgrund'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Entlassungsgrund' to 'http://fhir.de/StructureDefinition/Entlassungsgrund|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Aufnahmegrund'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Aufnahmegrund' to 'http://fhir.de/StructureDefinition/Aufnahmegrund|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/EncounterStatusDe'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/EncounterStatusDe' to 'http://fhir.de/ValueSet/EncounterStatusDe|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/kontaktebene-de'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/kontaktebene-de' to 'http://fhir.de/ValueSet/kontaktebene-de|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel' to 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert' to 'http://fhir.de/ValueSet/dkgev/Fachabteilungsschluessel-erweitert|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/DiagnoseTyp'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/DiagnoseTyp' to 'http://fhir.de/ValueSet/DiagnoseTyp|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/Diagnosesubtyp'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/Diagnosesubtyp' to 'http://fhir.de/ValueSet/Diagnosesubtyp|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Wahlleistung'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Wahlleistung' to 'http://fhir.de/StructureDefinition/Wahlleistung|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass' to 'http://fhir.de/ValueSet/dgkev/Aufnahmeanlass|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKKontaktGesundheitseinrichtung.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/Entlassungsgrund'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/Entlassungsgrund' to 'http://fhir.de/StructureDefinition/Entlassungsgrund|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-kvid-10'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-kvid-10' to 'http://fhir.de/StructureDefinition/identifier-kvid-10|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-kvid-10'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-kvid-10' to 'http://fhir.de/StructureDefinition/identifier-kvid-10|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-kvid-10'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-kvid-10' to 'http://fhir.de/StructureDefinition/identifier-kvid-10|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-pid'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-pid' to 'http://fhir.de/StructureDefinition/identifier-pid|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/identifier-type-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/identifier-type-de-basis' to 'http://fhir.de/ValueSet/identifier-type-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-pkv'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-pkv' to 'http://fhir.de/StructureDefinition/identifier-pkv|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/identifier-type-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/identifier-type-de-basis' to 'http://fhir.de/ValueSet/identifier-type-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-iknr'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-iknr' to 'http://fhir.de/StructureDefinition/identifier-iknr|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/identifier-type-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/identifier-type-de-basis' to 'http://fhir.de/ValueSet/identifier-type-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-iknr'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-iknr' to 'http://fhir.de/StructureDefinition/identifier-iknr|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-de-basis' to 'http://fhir.de/StructureDefinition/humanname-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-namenszusatz'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-namenszusatz' to 'http://fhir.de/StructureDefinition/humanname-namenszusatz|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-name'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-name' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-name|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier' to 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/name-part-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '4.0.1', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/name-part-qualifier' to 'http://hl7.org/fhir/ValueSet/name-part-qualifier|4.0.1'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-de-basis' to 'http://fhir.de/StructureDefinition/humanname-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-namenszusatz'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-namenszusatz' to 'http://fhir.de/StructureDefinition/humanname-namenszusatz|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-name'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-name' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-name|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix' to 'http://hl7.org/fhir/StructureDefinition/humanname-own-prefix|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier' to 'http://hl7.org/fhir/StructureDefinition/iso21090-EN-qualifier|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/gender-amtlich-de'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/gender-amtlich-de' to 'http://fhir.de/StructureDefinition/gender-amtlich-de|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/data-absent-reason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/data-absent-reason' to 'http://hl7.org/fhir/StructureDefinition/data-absent-reason|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/iso/bundeslaender'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/iso/bundeslaender' to 'http://fhir.de/ValueSet/iso/bundeslaender|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString' to 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-precinct|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-streetName|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-houseNumber|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-additionalLocator|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox' to 'http://hl7.org/fhir/StructureDefinition/iso21090-ADXP-postBox|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/iso/bundeslaender'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/iso/bundeslaender' to 'http://fhir.de/ValueSet/iso/bundeslaender|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString' to 'http://hl7.org/fhir/StructureDefinition/iso21090-codedString|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-kvid-10'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-kvid-10' to 'http://fhir.de/StructureDefinition/identifier-kvid-10|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-pid'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-pid' to 'http://fhir.de/StructureDefinition/identifier-pid|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-pkv'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-pkv' to 'http://fhir.de/StructureDefinition/identifier-pkv|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-de-basis' to 'http://fhir.de/StructureDefinition/humanname-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/humanname-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/humanname-de-basis' to 'http://fhir.de/StructureDefinition/humanname-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/gender-amtlich-de'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/gender-amtlich-de' to 'http://fhir.de/StructureDefinition/gender-amtlich-de|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/data-absent-reason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/data-absent-reason' to 'http://hl7.org/fhir/StructureDefinition/data-absent-reason|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKPatient.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedur.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum' to 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedur.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedur.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/seitenlokalisation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/seitenlokalisation' to 'http://fhir.de/StructureDefinition/seitenlokalisation|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedur.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedur.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedur.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum' to 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedur.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedur.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedurBeatmung.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum' to 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedurBeatmung.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedurBeatmung.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/seitenlokalisation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/seitenlokalisation' to 'http://fhir.de/StructureDefinition/seitenlokalisation|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedurBeatmung.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedurBeatmung.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedurReanimation.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum' to 'http://fhir.de/StructureDefinition/ProzedurDokumentationsdatum|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedurReanimation.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedurReanimation.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/seitenlokalisation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/seitenlokalisation' to 'http://fhir.de/StructureDefinition/seitenlokalisation|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedurReanimation.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/CodingOPS'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/CodingOPS' to 'http://fhir.de/StructureDefinition/CodingOPS|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKProzedurReanimation.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions.r4#5.3.0-ballot-tc1). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.3.0'StructureDefinition
input/resources/StructureDefinition-ISiKStandort.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-standortnummer'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-standortnummer' to 'http://fhir.de/StructureDefinition/identifier-standortnummer|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKStandort.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0116'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#6.5.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0116' to 'http://terminology.hl7.org/ValueSet/v2-0116|3.0.0'StructureDefinition
input/resources/StructureDefinition-ISiKStandort.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType' to 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType|3.0.0'StructureDefinition
input/resources/StructureDefinition-ISiKStandort.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKStandort.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/identifier-standortnummer'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/identifier-standortnummer' to 'http://fhir.de/StructureDefinition/identifier-standortnummer|1.6.0'StructureDefinition
input/resources/StructureDefinition-ISiKStandort.jsonThere are multiple different potential matches for the url 'http://fhir.de/StructureDefinition/address-de-basis'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/StructureDefinition/address-de-basis' to 'http://fhir.de/StructureDefinition/address-de-basis|1.6.0'StructureDefinition
input/resources/ValueSet-ISiKEncounterClassDE.jsonThere are multiple different potential matches for the url 'http://fhir.de/ValueSet/EncounterClassDE'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.6.0', found versions: 1.5.4 (from de.basisprofil.r4#1.5.4), 1.6.0 (from de.basisprofil.r4#1.6.0). Suggested fix: change the canonical reference from 'http://fhir.de/ValueSet/EncounterClassDE' to 'http://fhir.de/ValueSet/EncounterClassDE|1.6.0'ValueSet

TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE

fsh-generated/resources/ImplementationGuide-organspendeerkennung.jsonA definition could not be found for Canonical URL 'http://fhir.org/packages/de.basisprofil.r4/ImplementationGuide/de.basisprofil.r4'ImplementationGuide
input/resources/CapabilityStatement-ISiKCapabilityStatementErweiterteStammdatenRolle.jsonA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/ImplementationGuide/ISiK-Basismodul'CapabilityStatement
input/resources/CapabilityStatement-ISiKCapabilityStatementOrganspendeerkennungSourceAkteur-expanded.jsonA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/SearchParameter/Location-characteristic'CapabilityStatement
input/resources/CapabilityStatement-ISiKCapabilityStatementOrganspendeerkennungSourceRolle.jsonA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/SearchParameter/Location-characteristic'CapabilityStatement
input/resources/CapabilityStatement-ISiKCapabilityStatementStammdatenRolle.jsonA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/ImplementationGuide/ISiK-Basismodul'CapabilityStatement
input/resources/StructureDefinition-ISiKLaboruntersuchung.jsonA definition could not be found for Canonical URL 'http://hl7.org/fhir/uv/ips/ValueSet/results-coded-values-laboratory-uv-ips'StructureDefinition
input/resources/StructureDefinition-ISiKLaboruntersuchung.jsonA definition could not be found for Canonical URL 'http://hl7.org/fhir/uv/ips/ValueSet/results-coded-values-laboratory-uv-ips'StructureDefinition
input/resources/StructureDefinition-ISiKLaboruntersuchungSerumnatrium.jsonA definition could not be found for Canonical URL 'http://hl7.org/fhir/uv/ips/ValueSet/results-coded-values-laboratory-uv-ips'StructureDefinition
input/resources/StructureDefinition-mii-pr-icu-vent-spontane-atemfrequenz-beatmet.jsonA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'StructureDefinition
input/resources/StructureDefinition-mii-pr-icu-vent-spontanes-atemzugvolumen.jsonA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'StructureDefinition
input/resources/StructureDefinition-mii-pr-icu-vent-unterstuezungsdruck-beatmung.jsonA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'StructureDefinition
input/resources/StructureDefinition-mii-pr-vent-icu-parameter-von-beatmung.jsonA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'StructureDefinition
input/resources/StructureDefinition-mii-pr-vent-icu-parameter-von-beatmung.jsonA definition could not be found for Canonical URL 'https://gematik.de/fhir/isik/StructureDefinition/mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung'StructureDefinition

Terminology_PassThrough_TX_Message

input/resources/StructureDefinition-ISiKProzedurReanimation.jsonThere are no valid display names found for the code http://snomed.info/sct#439569004 for language(s) 'de-DE'. The display is 'Resuscitation (procedure)' which is a valid display for the default language (for 'http://snomed.info/sct#439569004')StructureDefinition
input/resources/StructureDefinition-ISiKProzedurReanimation.jsonThere are no valid display names found for the code http://snomed.info/sct#439569004 for language(s) 'de-DE'. The display is 'Resuscitation (procedure)' which is a valid display for the default language (for 'http://snomed.info/sct#439569004')StructureDefinition

Terminology_TX_Confirm_4a

input/resources/Procedure-ReanimationBeispiel.jsonThe code provided (http://fhir.de/CodeSystem/bfarm/ops#8-771) was not found in the value set 'ProzedurenReanimationCodesOPS' (https://gematik.de/fhir/isik/ValueSet/ProzedurenReanimationCodesOPS|6.0.0), and a code from this value set is required: Cannot invoke "String.length()" because "prefix" is nullISiK Prozedur Reanimation

Terminology_TX_NoValid_1_CC

input/resources/Observation-ExampleOrganRASS20200311.jsonNone of the codings provided are in the value set 'MII VS ICU Score RASS' (https://gematik.de/fhir/isik/ValueSet/mii-vs-icu-score-rass|6.0.0), and a coding from this value set is required) (codes = http://loinc.org#LA33966-5)MII PR ICU Score RASS

Terminology_TX_NoValid_3_CC

input/resources/Encounter-Fachabteilungskontakt.jsonNone of the codings provided are in the value set 'DiagnosisRole' (http://hl7.org/fhir/ValueSet/diagnosis-role|4.0.1), and a coding is recommended to come from this value set (codes = http://fhir.de/CodeSystem/KontaktDiagnoseProzedur#treatment-diagnosis)ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonNone of the codings provided are in the value set 'DiagnosisRole' (http://hl7.org/fhir/ValueSet/diagnosis-role|4.0.1), and a coding is recommended to come from this value set (codes = http://fhir.de/CodeSystem/KontaktDiagnoseProzedur#treatment-diagnosis)ISiKKontaktGesundheitseinrichtung
input/resources/Observation-ExampleISiKLaboruntersuchungMaximal.jsonNone of the codings provided are in the value set 'Observation Category Codes' (http://hl7.org/fhir/ValueSet/observation-category|4.0.1), and a coding is recommended to come from this value set (codes = http://loinc.org#18727-8)ISiKLaboruntersuchung

Terminology_TX_ValueSet_NotFound

input/resources/Observation-ExampleISiKLaboruntersuchungMaximal.jsonValueSet 'http://hl7.org/fhir/uv/ips/ValueSet/results-coded-values-laboratory-uv-ips' not foundISiKLaboruntersuchung

Type_Specific_Checks_DT_String_WS

fsh-generated/resources/ImplementationGuide-organspendeerkennung.jsonvalue should not start or finish with whitespace '\nDieses Profil ermöglicht die Abbildung von Besuchen/Aufenthalten eines Patienten in einer Gesundheitseinrichtung.\n\n**Motivation**\n\nInformationen über die Besuche des Patienten entlang seines \nBehandlungspfades im Krankenhaus sind ein wichtiger Bestandteil \ndes einrichtungsinternen Datenaustausches. \nSie ermöglichen die Unterscheidung von stationären und ambulanten \nsowie aufgenommenen und entlassenen Patienten. \nWeiterhin ist aus den Besuchsinformationen der aktuelle Aufenthaltsort \ndes Patienten (Fachabteilung, Station, Bettplatz) ermittelbar. \nKlinische Ressourcen werden in FHIR durch Verlinkung auf die \nEncounter-Ressource in einen Kontext zum Besuch gestellt. \nDieser Kontext ist wichtig für die Steuerung von Zugriffsberechtigungen \nund Abrechnungsprozessen. \n\nZu Beginn der meisten klinischen Workflows steht die Auswahl \ndes Besuchskontextes. \nDies geschieht bspw. durch das Suchen der Encounter-Ressource \nanhand von Eigenschaften wie Aufnahmenummer, Fallart oder Aufnahmedatum. \nDaraufhin werden die zutreffenden Suchergebnisse angezeigt \nund der gewünschte Besuch ausgewählt.\n\nIn FHIR werden Besuche, Aufenthalte, aber auch virtuelle Kontakte mit der `Encounter`-Ressource repräsentiert.\n\nWeitere Hinweise zu den Abgrenzungen der Begrifflichkeiten Fall und Kontakt finden sie unter [Fall-Begriff in ISiK](https://gemspec.gematik.de/ig/fhir/isik/basis/6.0.0-rc1/Abbildung-des-Konstrukts-Fall.html).\n\n**Kompatibilität**\n\nFür das Profil ISiKKontaktGesundheitseinrichtung wird eine Kompatibilität \nmit folgenden Profilen angestrebt; \nallerdings kann nicht sichergestellt werden, dass Instanzen, \ndie gegen ISiKKontaktGesundheitseinrichtung valide sind, \nauch valide sind gegen:\n\n* Profil [Kontakt mit einer Gesundheitseinrichtung \nder Medizininformatik-Initiative](https://www.medizininformatik-initiative.de/fhir/core/modul-fall/StructureDefinition/KontaktGesundheitseinrichtung)\n\nHinweise zu Inkompatibilitäten können über die [Portalseite](https://service.gematik.de/servicedesk/customer/portal/16) gemeldet werden.'ImplementationGuide
fsh-generated/resources/ImplementationGuide-organspendeerkennung.jsonvalue should not start or finish with whitespace ' Zulaessige Koerperstellen fuer lateralisierte Pupillenbefunde: linke oder rechte Pupille.\n\nDie Datenstruktur wurde dem laufenden Stand der Entwicklung des MII ICU Module entnommen - https://github.com/medizininformatik-initiative/kerndatensatzmodul-intensivmedizin/blob/master/input/fsh/valuesets/MII_VS_ICU_BodySite_Observation_Pupillenbefund.fsh - Details zur Kompatibilität mit dem ISiK Package der Stufe 6 wurden angepasst und Metadaten des Ursprungsschemas zum Teil entfernt. Stand 04.03.2026'ImplementationGuide

Type_Specific_Checks_DT_URL_Resolve

input/resources/Encounter-Fachabteilungskontakt.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/besuchsnummer'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-Fachabteilungskontakt.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/fallnummer'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-Fachabteilungskontakt.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/locationid'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-Fachabteilungskontakt.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/fachabteilungsid'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktBettenverlegung.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktBettenverlegung.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktBettenverlegung.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktBettenverlegung.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktEntlassung.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktEntlassung.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktEntlassung.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktFachbereichswechsel1.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktFachbereichswechsel1.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktFachbereichswechsel1.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktFachbereichswechsel1.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktFachbereichswechsel2.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktFachbereichswechsel2.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktFachbereichswechsel2.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/besuchsnummer'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/fallnummer'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/roomid'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bedid'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationid'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationid'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktNormal.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/fachabteilungsid'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationaereAufnahme.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationaereAufnahme.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationaereAufnahme.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationswechsel1.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationswechsel1.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationswechsel1.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationswechsel2.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/stationId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationswechsel2.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/zimmerId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-FachabteilungskontaktStationswechsel2.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/bettId'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Nachstationaer.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/besuchsnummer'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Nachstationaer.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/fallnummern'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Stationaer.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/besuchsnummer'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Stationaer.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/fallnummern'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Stationaer.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/betten'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Stationaer.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/zimmer'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Vorstationaer.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/besuchsnummer'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ1Vorstationaer.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/fallnummern'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ2Encounter.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/besuchsnummer'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-SZ2Encounter.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/fallnummern'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-isik-encounter-Sternenfall.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/aufnahmenummer'ISiKKontaktGesundheitseinrichtung
input/resources/Encounter-isik-encounter-Sternenfall.jsonNo definition could be found for URL value 'https://test.krankenhaus.de/fhir/sid/fallnummer'ISiKKontaktGesundheitseinrichtung
input/resources/Location-KrankenhausStandortBeispiel.jsonNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer'ISiKStandort
input/resources/Location-StationICUStandortBeispiel.jsonNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer'ISiKStandort
input/resources/Location-StationPediaICUStandortBeispiel.jsonNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer'ISiKStandort
input/resources/Location-StationStandortBeispiel.jsonNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer'ISiKStandort
input/resources/Location-isik-station-anaesthesie.jsonNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer'ISiKStandort
input/resources/Patient-DorisQuelle.jsonNo definition could be found for URL value 'https://fhir.krankenhaus.example/sid/PID'ISiKPatient
input/resources/Patient-DorisZiel.jsonNo definition could be found for URL value 'https://fhir.krankenhaus.example/sid/PID'ISiKPatient
input/resources/Patient-PatientinMinimal.jsonNo definition could be found for URL value 'https://fhir.krankenhaus.example/sid/PID'ISiKPatient
input/resources/Patient-PatientinMusterfrau.jsonNo definition could be found for URL value 'https://fhir.krankenhaus.example/sid/PID'ISiKPatient
input/resources/Patient-PatientinNormal.jsonNo definition could be found for URL value 'https://fhir.krankenhaus.example/sid/PID'ISiKPatient
input/resources/Patient-SZ1Patient.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/Patienten'ISiKPatient
input/resources/Patient-SZ2Patient.jsonNo definition could be found for URL value 'http://beispiel-krankenhaus.de/sid/Patienten'ISiKPatient
input/resources/Patient-isik-patient-156722.jsonNo definition could be found for URL value 'https://example-krankenhaus.de/fhir/sid/pid'ISiKPatient
input/resources/StructureDefinition-ISiKStandort.jsonNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer'StructureDefinition
input/resources/StructureDefinition-ISiKStandort.jsonNo definition could be found for URL value 'http://fhir.de/sid/dkgev/standortnummer'StructureDefinition

UNKNOWN_CODESYSTEM_VERSION

input/resources/Procedure-ReanimationBeispiel.jsonA definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000274103/version/20251115' could not be found, so the code cannot be validated. Valid versions: http://snomed.info/sct/11000146104/version/20240930, http://snomed.info/sct/2011000195101/version/20230607, http://snomed.info/sct/554471000005108/version/20260331, http://snomed.info/sct/731000124108/version/20230301, http://snomed.info/sct/731000124108/version/20240301, http://snomed.info/sct/731000124108/version/20250901, http://snomed.info/sct/827022005/version/20241216, http://snomed.info/sct/83821000000107/version/20230412, http://snomed.info/sct/900000000000207008/version/20240201, http://snomed.info/sct/900000000000207008/version/20250201 and http://snomed.info/xsct/900000000000207008/version/20250814ISiK Prozedur Reanimation

UNKNOWN_CODESYSTEM_VERSION_NONE

input/resources/Procedure-Appendektomie.jsonA definition for CodeSystem 'http://fhir.de/CodeSystem/bfarm/ops' version '2024' could not be found, so the code cannot be validated. No versions of this code system are knownISiKProzedur

Unknown_Code_in_Version

input/resources/Observation-ExampleOrganRASS20200311.jsonUnknown code 'LA33966-5' in the CodeSystem 'http://loinc.org' version '2.82'MII PR ICU Score RASS

VALUESET_CODE_CONCEPT_HINT

input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'BLOOD BANK STUDIES' for http://loinc.org#18717-9. Valid display is 'Blutbank-Untersuchungen' (de-DE) (for the language(s) 'de-DE'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'CELL MARKER STUDIES' for http://loinc.org#18718-7. Valid display is one of 2 choices: 'Cell marker studies (set)' (en-US) or 'Cell marker studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'CHEMISTRY STUDIES' for http://loinc.org#18719-5. Valid display is one of 2 choices: 'Chemistry studies (set)' (en-US) or 'Chemistry studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'COAGULATION STUDIES' for http://loinc.org#18720-3. Valid display is one of 2 choices: 'Coagulation studies (set)' (en-US) or 'Coagulation studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'THERAPEUTIC DRUG MONITORING STUDIES' for http://loinc.org#18721-1. Valid display is one of 2 choices: 'Therapeutic drug monitoring studies (set)' (en-US) or 'Therapeutic drug monitoring studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'FERTILITY STUDIES' for http://loinc.org#18722-9. Valid display is one of 2 choices: 'Fertility studies (set)' (en-US) or 'Fertility studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'HEMATOLOGY STUDIES' for http://loinc.org#18723-7. Valid display is one of 2 choices: 'Hematology studies (set)' (en-US) or 'Hematology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'SEROLOGY STUDIES' for http://loinc.org#18727-8. Valid display is one of 2 choices: 'Serology studies (set)' (en-US) or 'Serology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'TOXICOLOGY STUDIES' for http://loinc.org#18728-6. Valid display is one of 2 choices: 'Toxicology studies (set)' (en-US) or 'Toxicology studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'URINALYSIS STUDIES' for http://loinc.org#18729-4. Valid display is one of 2 choices: 'Urinalysis studies (set)' (en-US) or 'Urinalysis studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'BLOOD GAS STUDIES' for http://loinc.org#18767-4. Valid display is one of 2 choices: 'Blood gas studies (set)' (en-US) or 'Blood gas studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'CELL COUNTS+DIFFERENTIAL STUDIES' for http://loinc.org#18768-2. Valid display is one of 2 choices: 'Cell counts+Differential studies (set)' (en-US) or 'Cell counts+Differential studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'LABORATORY STUDIES' for http://loinc.org#26436-6. Valid display is one of 2 choices: 'Laboratory studies (set)' (en-US) or 'Laboratory studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ISiKLaborbereichVS.jsonWrong Display Name 'CHEMISTRY CHALLENGE STUDIES' for http://loinc.org#26437-4. Valid display is one of 2 choices: 'Chemistry challenge studies (set)' (en-US) or 'Chemistry challenge studies (set)' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ObservationCodesSerumnatrium.jsonWrong Display Name 'Sodium [Moles/volume] in Serum or Plasma' for http://loinc.org#2951-2. Valid display is 'Natrium [Mol/Volumen] in Serum oder Plasma' (de-DE) or 'Natrium' (de-AT) (for the language(s) 'de-DE'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ObservationUnitsSerumnatrium.jsonWrong Display Name 'millimol per liter' for http://unitsofmeasure.org#mmol/L. There are no valid display names found for language(s) 'de-DE'. Default display is 'mmol/L'. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ProzedurenKategorieSCT.jsonThere are no valid display names found for the code http://snomed.info/sct#165197003 for language(s) 'de-DE'. The display is 'Diagnostic assessment' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-ProzedurenKategorieSCT.jsonWrong Display Name 'Administration of medicine' for http://snomed.info/sct#18629005. Valid display is one of 9 choices: 'Administration of medication' (en), 'Administration of medication, NOS' (en), 'Giving medication' (en), 'Administration of medication (procedure)' (en), 'Medication administration' (en), 'Medication administration treatments and procedures' (en), 'Medication treatment' (en), 'Administration of drug or medicament (procedure)' (en) or 'Administration of drug or medicament' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-bodysite-observation-pupillenbefund.jsonThere are no valid display names found for the code http://snomed.info/sct#16089004 for language(s) 'de-DE'. The display is 'Structure of pupil of left eye' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc.jsonWrong Display Name 'Horowitz index in Arterial blood' for http://loinc.org#50984-4. Valid display is 'Horowitz-Index für arterielles Blut' (de-DE) (for the language(s) 'de-DE'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc-iso11073.jsonWrong whitespace in Display Name 'Total respiratory rate; total breath rate' for urn:iso:std:iso:11073:10101#152490. Valid display is 'MDC_VENT_RESP_BTSD_PSAZC_RATE' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc-iso11073.jsonWrong Display Name 'Inspiratory time setting' for urn:iso:std:iso:11073:10101#16929632. Valid display is 'MDC_VENT_TIME_PD_INSP_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc-iso11073.jsonWrong Display Name 'Tidal volume setting' for urn:iso:std:iso:11073:10101#16929196. Valid display is 'MDC_VENT_VOL_TIDAL_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc-iso11073.jsonWrong Display Name 'High pressure hold time setting Ventilator' for urn:iso:std:iso:11073:10101#16929860. Valid display is 'MDC_VENT_TIME_PD_INSP_THIGH_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc-iso11073.jsonWrong Display Name 'Low pressure hold time setting Ventilator' for urn:iso:std:iso:11073:10101#16929864. Valid display is 'MDC_VENT_TIME_PD_EXP_TLOW_SETTING' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc-iso11073.jsonWrong Display Name 'Mean pressure Respiratory system airway --on ventilator' for urn:iso:std:iso:11073:10101#151975. Valid display is 'MDC_VENT_PRESS_AWAY_MEAN' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-loinc-iso11073.jsonWrong Display Name 'Pressure.max Respiratory system airway --on ventilator' for urn:iso:std:iso:11073:10101#151973. Valid display is 'MDC_VENT_PRESS_AWAY_MAX' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-beatmung-snomed.jsonThere are no valid display names found for the code http://snomed.info/sct#250822000 for language(s) 'de-DE'. The display is 'Inspiration/expiration time ratio (observable entity)' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-pupillengroesse.jsonThere are no valid display names found for the code http://snomed.info/sct#420335002 for language(s) 'de-DE'. The display is 'Medium size pupil' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-pupillenlichtreaktion.jsonThere are no valid display names found for the code http://loinc.org#LA25441-9 for language(s) 'de-DE'. The display is 'Reactive to light' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-observation-pupillensymmetrie.jsonThere are no valid display names found for the code http://snomed.info/sct#301943000 for language(s) 'de-DE'. The display is 'Pupils equal (finding)' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-oservation-pupillenform-loinc.jsonThere are no valid display names found for the code http://loinc.org#LA24884-1 for language(s) 'de-DE'. The display is 'Round' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-procedure-beatmung-snomed.jsonThere are no valid display names found for the code http://snomed.info/sct#1149092001 for language(s) 'de-DE'. The display is 'Positive pressure ventilation' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-code-procedure-beatmung-snomed.jsonWrong Display Name 'Kontinuierliche positive Atemwegsdruckbeatmung' for http://snomed.info/sct#47545007. Valid display is one of 9 choices: 'Continuous positive airway pressure ventilation treatment' (en), 'CPAP treatment' (en), 'Continuous positive airway pressure ventilation treatment (procedure)' (en), 'CPAP - Continuous positive airways pressure' (en), 'CPAP - Continuous positive airways pressure therapy' (en), 'Continuous positive airways pressure therapy' (en), 'Continuous positive airway pressure ventilation treatment (regime/therapy)' (en), 'CPAP (continuous positive airway pressure) therapy' (en) or 'CPAP (continuous positive airway pressure) treatment' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-score-rass.jsonThere are no valid display names found for the code http://loinc.org#LA17287-6 for language(s) 'de-DE'. The display is 'Combative' which is a valid display for the default language. Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-mii-vs-icu-score-rass.jsonWrong Display Name 'Restless +1' for http://loinc.org#LA16474-1. Valid display is 'Restless' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-iso11073.jsonWrong Display Name 'Oxygen saturation in Arterial blood by Pulse oximetry' for urn:iso:std:iso:11073:10101#150456. Valid display is 'MDC_PULS_OXIM_SAT_O2' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-iso11073.jsonWrong Display Name 'Esophageal temperature' for urn:iso:std:iso:11073:10101#150372. Valid display is 'MDC_TEMP_ESOPH' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-iso11073.jsonWrong Display Name 'Nasopharynx temperature' for urn:iso:std:iso:11073:10101#150380. Valid display is 'MDC_TEMP_NASOPH' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-iso11073.jsonWrong Display Name 'Arterial oxygen saturation' for urn:iso:std:iso:11073:10101#150324. Valid display is 'MDC_SAT_O2_ART' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-iso11073.jsonWrong Display Name 'Ideal body weight (IBW)' for urn:iso:std:iso:11073:10101#188796. Valid display is 'MDC_MASS_BODY_EST_IBW' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-iso11073.jsonWrong Display Name 'Tympanic temperature' for urn:iso:std:iso:11073:10101#150392. Valid display is 'MDC_TEMP_TYMP' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-iso11073.jsonWrong Display Name 'Airway temperature' for urn:iso:std:iso:11073:10101#150356. Valid display is 'MDC_TEMP_AWAY' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-loinc.jsonWrong Display Name 'Heart Rate' for http://loinc.org#8867-4. Valid display is 'Herzfrequenz' (de-DE) or 'Puls' (de-AT) (for the language(s) 'de-DE'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-loinc.jsonWrong Display Name 'Sauerstoffsättigung in arteriellem Blut mittels Pulsoximetrie' for http://loinc.org#59408-5. Valid display is one of 3 choices: 'Oxygen saturation in Arterial blood by Pulse oximetry' (en-US), 'Oxygen saturation in Arterial blood by Pulse oximetry' (en-US) or 'SaO2 % BldA PulseOx' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-loinc.jsonWrong Display Name 'Körpergewicht' for http://loinc.org#29463-7. Valid display is one of 3 choices: 'Body weight' (en-US), 'Body weight' (en-US) or 'Weight' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-loinc.jsonWrong Display Name 'Körpergröße' for http://loinc.org#8302-2. Valid display is one of 3 choices: 'Body height' (en-US), 'Body height' (en-US) or 'Body height' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-loinc.jsonWrong Display Name 'Körpergewicht [Perzentil] pro Alter' for http://loinc.org#8336-0. Valid display is one of 3 choices: 'Body weight [Percentile] Per age' (en-US), 'Body weight [Percentile] Per age' (en-US) or 'Bdy weight Prctl Per Age' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-loinc.jsonWrong Display Name 'Körpertemperatur - Harnblase' for http://loinc.org#8334-5. Valid display is one of 3 choices: 'Body temperature - Urinary bladder' (en-US), 'Body temperature - Urinary bladder' (en-US) or 'Bdy temp Bladder' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-loinc.jsonWrong Display Name 'Körpertemperatur - gemessen im Blut' for http://loinc.org#60834-9. Valid display is one of 3 choices: 'Blood temperature' (en-US), 'Blood temperature' (en-US) or 'Blood temp' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-loinc.jsonWrong Display Name 'Körpertemperatur' for http://loinc.org#8310-5. Valid display is one of 3 choices: 'Body temperature' (en-US), 'Body temperature' (en-US) or 'Body temperature' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.jsonWrong Display Name 'Körpergewicht' for http://snomed.info/sct#27113001. Valid display is one of 3 choices: 'Body weight' (en), 'Body weight, NOS' (en) or 'Body weight (observable entity)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.jsonWrong Display Name 'Körpergröße' for http://snomed.info/sct#1153637007. Valid display is one of 2 choices: 'Body height (observable entity)' (en) or 'Body height' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.jsonWrong Display Name 'Körperkerntemperatur gemessen am Trommelfell' for http://snomed.info/sct#415974002. Valid display is one of 5 choices: 'Tympanic temperature (observable entity)' (en), 'Tympanic temperature' (en), 'Aural temperature' (en), 'Core body temperature measured at tympanic membrane (observable entity)' (en) or 'Core body temperature measured at tympanic membrane' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.jsonWrong Display Name 'Rektaltemperatur' for http://snomed.info/sct#307047009. Valid display is one of 4 choices: 'Rectal temperature' (en), 'Rectal temperature (observable entity)' (en), 'Core body temperature measured in rectum (observable entity)' (en) or 'Core body temperature measured in rectum' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.jsonWrong Display Name 'Körperkerntemperatur gemessen im Ösophagus' for http://snomed.info/sct#431598003. Valid display is one of 6 choices: 'Temperature of esophagus (observable entity)' (en), 'Temperature of esophagus' (en), 'Temperature of oesophagus' (en), 'Core body temperature measured in esophagus (observable entity)' (en), 'Core body temperature measured in esophagus' (en) or 'Core body temperature measured in oesophagus' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.jsonWrong Display Name 'Körperkerntemperatur gemessen im Nasopharynx' for http://snomed.info/sct#698831002. Valid display is one of 4 choices: 'Nasopharyngeal temperature' (en), 'Nasopharyngeal temperature (observable entity)' (en), 'Core body temperature measured in nasopharynx (observable entity)' (en) or 'Core body temperature measured in nasopharynx' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.jsonWrong Display Name 'Körperkerntemperatur gemessen an der Harnblase' for http://snomed.info/sct#698832009. Valid display is one of 8 choices: 'Bladder temperature (observable entity)' (en), 'Bladder temperature' (en), 'Intravesical temperature' (en), 'Temperature of bladder' (en), 'Temperature of urinary bladder' (en), 'Core body temperature measured at urinary bladder (observable entity)' (en), 'Core body temperature measured at urinary bladder' (en) or 'Urinary bladder temperature' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.jsonWrong Display Name 'Vaginaltemperatur' for http://snomed.info/sct#364246006. Valid display is one of 4 choices: 'Temperature of vagina' (en), 'Temperature of vagina (observable entity)' (en), 'Core body temperature measured vaginally (observable entity)' (en) or 'Core body temperature measured vaginally' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.jsonWrong Display Name 'Orale Temperatur' for http://snomed.info/sct#415945006. Valid display is one of 6 choices: 'Oral temperature (observable entity)' (en), 'Oral temperature' (en), 'Core body temperature measured in sublingual space (observable entity)' (en), 'Core body temperature measured in sublingual space' (en), 'Estimated core body temperature measured in sublingual space (observable entity)' (en) or 'Estimated core body temperature measured in sublingual space' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.jsonWrong Display Name 'Körperkerntemperatur im Blut gemessen' for http://snomed.info/sct#1222808002. Valid display is one of 3 choices: 'Temperature of blood' (en), 'Core body temperature measured in blood (observable entity)' (en) or 'Core body temperature measured in blood' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
input/resources/ValueSet-vs-mii-icu-code-monitoring-und-vitaldaten-snomed.jsonWrong Display Name 'Stirntemperatur' for http://snomed.info/sct#415922000. Valid display is one of 4 choices: 'Forehead temperature (observable entity)' (en), 'Forehead temperature' (en), 'Temperature of forehead (observable entity)' (en) or 'Temperature of forehead' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--

VALUESET_CONCEPT_DISPLAY_SCT_TAG_MIXED

input/resources/ValueSet-ProzedurenKategorieSCT.jsonThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Resuscitation (procedure)] and examples for no FSN: [Diagnostic assessment, Imaging, Surgical procedure, Administration of medicine, Therapeutic procedure])--
input/resources/ValueSet-mii-vs-icu-category-procedure-beatmung-snomed.jsonThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Oxygen therapy (procedure)] and examples for no FSN: [Künstliche Beatmung])--
input/resources/ValueSet-mii-vs-icu-code-procedure-beatmung-snomed.jsonThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Respiratory therapy (procedure), Respiratory assist, manual (procedure), Control of end expiratory pressure (procedure), Pulmonary resuscitation (procedure), Positive airway pressure therapy (regime/therapy)] and examples for no FSN: [Positive pressure ventilation, Mechanically assisted spontaneous ventilation, Non-invasive ventilation, Kontinuierliche positive Atemwegsdruckbeatmung, Dual pressure spontaneous ventilation support])--

VALUESET_INCLUDE_INVALID_CONCEPT_CODE

input/resources/ValueSet-mii-vs-icu-score-rass.jsonThe code 'LA33959-0' is not valid in the system http://loinc.org (Unknown code 'LA33959-0' in the CodeSystem 'http://loinc.org' version '2.82')--
input/resources/ValueSet-mii-vs-icu-score-rass.jsonThe code 'LA33960-8' is not valid in the system http://loinc.org (Unknown code 'LA33960-8' in the CodeSystem 'http://loinc.org' version '2.82')--
input/resources/ValueSet-mii-vs-icu-score-rass.jsonThe code 'LA33962-4' is not valid in the system http://loinc.org (Unknown code 'LA33962-4' in the CodeSystem 'http://loinc.org' version '2.82')--
input/resources/ValueSet-mii-vs-icu-score-rass.jsonThe code 'LA33963-2' is not valid in the system http://loinc.org (Unknown code 'LA33963-2' in the CodeSystem 'http://loinc.org' version '2.82')--
input/resources/ValueSet-mii-vs-icu-score-rass.jsonThe code 'LA33964-0' is not valid in the system http://loinc.org (Unknown code 'LA33964-0' in the CodeSystem 'http://loinc.org' version '2.82')--
input/resources/ValueSet-mii-vs-icu-score-rass.jsonThe code 'LA33965-7' is not valid in the system http://loinc.org (Unknown code 'LA33965-7' in the CodeSystem 'http://loinc.org' version '2.82')--
input/resources/ValueSet-mii-vs-icu-score-rass.jsonThe code 'LA33966-5' is not valid in the system http://loinc.org (Unknown code 'LA33966-5' in the CodeSystem 'http://loinc.org' version '2.82')--
input/resources/ValueSet-mii-vs-icu-score-rass.jsonThe code 'LA33967-3' is not valid in the system http://loinc.org (Unknown code 'LA33967-3' in the CodeSystem 'http://loinc.org' version '2.82')--

VALUESET_INC_CS_NO_SUPPORT

input/resources/ValueSet-ProzedurenReanimationCodesOPS.jsonThe concepts in the value set include have not been validated because the code system 'http://fhir.de/CodeSystem/bfarm/ops' is not known, and no terminology service supports it--