This specification describes the technical semantic approach for providing vital signs (vibW) using blood glucose, Continuous glucose monitoring, lung function testing and blood pressure as an example, according to § 374a SGB V.
first
true
ci-build
https://gemspec.gematik.de/ig/fhir/hddt/1.0.0
RelatedIgs
(None Found)
Error fetching package-list from https://gematik.de/fhir/hddt: Error parsing JSON source: Unexpected content '<' in json format at Line 3 (path=[null])
This IG has never been published, so the version should start with '0.' or include a patch version e.g. '-ballot'
This release is not labelled as a milestone or technical correction, so should have a patch version (1.0.0)
No publication request category found (needed for first publication - consult FHIR product director for a value
No publication request title found (needed for first publication)
No publication description (`registry-description`) found (needed for first publication)
No publication country (`registry-country`) found (needed for first publication)
No publication authority (`registry-authority`) found (needed for first publication)
No publication request introduction found (needed for first publication)
Unable to compare with previous version: Unable to find version history at https://gematik.de/fhir/hddt (Problem #1 with package-list.json at https://gematik.de/fhir/hddt: Error parsing JSON source: Unexpected content '<' in json format at Line 3 (path=[null]))
IPA Comparison:
n/a
IPS Comparison:
n/a
Validation Flags:
On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
ERROR: SNOMED CT German edition validation. Reason: The terminology server of HL7 (tx.fhir.org) currently does not provide the German edition of SNOMED CT. Therefore, validation of German designations may fail. This will be resolved once the German edition is available on the central German terminology server.
%None of the codings provided are in the value set 'Device Type of personal health devices'% (0 uses)
INFORMATION: Blood Pressure component slicing. Reason: We use a custom HddtBloodPressureValue profile, IG Publisher trys to validate on the standard BP profile where the third component (mean blood pressure) is not part of.
%This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp% (2 uses)
INFORMATION: Codes not validated, because the terminology server does not support batch validation; Reason: The value set contains codes from SNOMED (German Edition) and the only terminology server that has this system, does not support the operation to fully validate the value set.
%The concepts in the value set include have not been validated because the terminology server https://tx.fhir.de/fhir does not support batch validation% (1 uses)
INFORMATION: Conformance term check. Reason: The reference to § 374a SGB V is explanatory background text only and not intended as a formal conformance statement. The hit does not indicate an error in the specification and can be safely ignored.
%No conformance term found in the text% (6 uses)
INFORMATION: Discriminator type 'pattern' is deprecated in R5. However, we want to establish compatibility with R4.
%The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead% (3 uses)
INFORMATION: LOINC codes not validated for performance reasons.Reason: Triggers only on one ConceptMap that translates to LOINC. Since building process would take too long without a terminology server, ig-publisher does not validate codes from LOINC.
%Target Code System http://loinc.org is only supported on the terminology server% (1 uses)
INFORMATION: Missing publish box in generated HTML.Reason: This IG is not an official HL7 publication, so the 'publish box' requirement does not apply. The warning appears once per build and can safely be suppressed.
%The html source does not contain the publish box% (1 uses)
INFORMATION: References to draft CodeSystems. Reasson: The IG uses draft CodeSystems for internal testing or national extensions that are not yet normatively published.
%Reference to draft CodeSystem% (0 uses)
WARNING: HTML has duplicate Anchor IDs. Reason: The file `measurement-lung-function.md` embeds three Observation profiles, each with a distinct 'diff' table. IG-publisher generates HTML-anchors with duplicate ids for each table.
% The html source has duplicate anchor Ids: diff_Observation,% (1 uses)
WARNING: Best practice recommendations. # Reason: These warnings refer to "Best Practice Recommendations" (e.g., subject, performer) that are not mandatory for all Observation profiles in this IG context.
%Best Practice Recommendation% (74 uses)
WARNING: CodeSystem not found. Reason: This CodeSystem is currently not published.
%A definition for CodeSystem 'https://fhir.bfarm.de/CodeSystem/HiisEndpointConnectionType' could not be found, so the code cannot be validated% (2 uses)
%A definition for CodeSystem 'https://fhir.bfarm.de/CodeSystem/HiisManufacturerType' could not be found% (2 uses)
WARNING: Definition for ImplementationGuide not found in the Basisprofil. Reason: The ImplementationGuide reference is not needed
%A definition could not be found for Canonical URL 'http://fhir.org/packages/de.basisprofil.r4/ImplementationGuide/de.basisprofil.r4'% (1 uses)
%The canonical URL http://fhir.org/packages/de.basisprofil.r4/ImplementationGuide/de.basisprofil.r4 doesn't point to an actual ImplementationGuide resource% (1 uses)
WARNING: Deprecated extension. Reason: The warning relates to an extension (elementdefinition-maxValueSet|5.2.0) that remains temporarily used for backward compatibility.
%The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.2.0 is deprecated% (1 uses)
WARNING: HTML fragment. Reason: We are using a custom template of our own
%HTML fragment% (4 uses)
WARNING: Observation performer / subject. Reason: Some Observation examples are intentionally abstracted or device-generated without explicit performer/subject for privacy or structural reasons.
%Alle Observations sollten ein Subject haben% (0 uses)
%Alle Observations sollten einen Performer haben% (0 uses)
WARNING: SNOMED CT German edition validation. Reason: The terminology server of HL7 (tx.fhir.org) currently does not provide the German edition of SNOMED CT. Therefore, validation of German designations may fail. This will be resolved once the German edition is available on the central German terminology server.
%A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000274103% (2 uses)
%Error from https://tx.fhir.org/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000274103% (0 uses)
%The concepts in the value set include have not been validated because the code system is not known, and no terminology service supports it% (0 uses)
WARNING: This is expected, since the Concept Map does not include any concrete LOINC codes, since none yet exists. The warning will disappear, once new LOINC codes have been published.
%The Target Code System http://loinc.org is not fully defined and populated, and no targetScope is specified, so the target code checking will not be performed% (0 uses)
WARNING: URL resolution for non-FHIR external systems. Reason: The URLs is a legitimate external reference (not a FHIR endpoint). It does not resolve via HTTP intentionally.
%No definition could be found for URL value% (2 uses)